Technical information
Technician’s Handbook
192
If this message appears:
Main Controller update applied successfully.
The update has been successfully applied.
– Updates have been applied. Proceed to the next step.
If this message appears:
ERROR: No update files were found
– There are no updates on the RSD. Proceed to the next 
step.
If this message appears:
ERROR: An update already exists on the system. UPDATE 
REMOVE must be executed.
– Enter:
UPDATE REMOVE
This message appears:
The Update has been removed.
Please, reload the main controller from the Winchester. As 
well, reload the slaves that were changed (if any).
– Enter:
UPDATE APPLY <volume name of RSD> FROM 
*.<volume name of RSD>
This message appears:
The update has been successfully applied. Please, reload the 
main controller from the Winchester. As well, reload the 
slaves that were changed (if any).
– Proceed to the next step.
5. Enter:
VOL DISMOUNT <volume name of RSD>
6. Remove the RSD from the RSD drive.
7. Hold down PANEL ENABLE and press the inactive 
plane’s RESET button.
8. Log on to the inactive plane and select maintenance 
mode.