Technical information

Technician’s Handbook
194
Performing an Option Upgrade
Options and MFRDs are Password Protected
Options and MFRDs are password protected. Call the
MITEL order desk to purchase a new set of options. You will
be given a new MITEL Options Password that will enable the
options and MFRDs on the system.
Before You Begin
Read the instructions outlined on page 169.
Enabling Options and MFRDs on Non-redundant
Systems
1. Make a DATA SAVE to RSD. See Making a DATA SAVE
Backup on page 164.
2. If you have the Message Center option, save message
center messages to RSD. See Making a Message
Center Backup on page 165.
3. Record your login usernames, passwords, and alarm
thresholds.
4. If required, record SUPERCONSOLE 1000 firmkey
programming.
5. Log on to the system and select customer data entry
mode.
6. Select System Forms from the Forms Group Menu.
7. Select the Dimension and Feature Select form from the
System Forms menu. Press the <edit form> softkey.
8. Set all options to match those on the SX-2000 Feature
Options Record sheet (X = YES).
9. Verify that the machine configuration is FD1 for a MICRO
LIGHT, or 9” redundant system, and that the maximum