Technical information

Routine Maintenance
195
Routine
Maintenance
number of cabinets is 5. Otherwise select FD2 and a
maximum number of 12 cabinets.
10.Press the <generate> softkey followed by the <bottom>
softkey.
11.Enter the MITEL options password (from the SX-2000
Feature Options Record sheet received with the
software); press the <commit> softkey, then the
<confirm> softkey.
This message appears:
Changes committed. ** Reload the system to make new values
effective. **
12.Quit the form.
13.Select maintenance mode and enter:
DBMS FLAG OFF
14.Hold down PANEL ENABLE and press the plane A
RESET button to enable the options. Service is lost
until you complete the DATA RESTORE.
15.Log on to the system and select maintenance mode.
16.Insert the datasave RSD in the RSD drive.
17.Enter:
VOL MOUNT RSD
Read the volume name of the RSD from the system
response on the maintenance terminal.
18.Enter:
DATA RESTORE .<volume name of RSD>
This message appears:
Delete old log file? (Yes/No)
Enter YES
This message appears:
Existing Data Save will be deleted from Harddisk. Continue?
(Y/N)
Enter YES
These messages appear:
FS info: Deleting files from catalog .DR.CONFIG
FS info: Deleting file .DR.CONFIG.TIMESTAMP
RSD 15 min
Tape 60 min