Technical information

Installation
17
Installation
Adding a Peripheral or DSU Cabinet
Service will be lost during this procedure.
1. If your system is redundant, hold down PANEL ENABLE
and press ACTIVITY FREEZE ON.
2. Install the peripheral or DSU cabinet.
3. Connect the fiber cable to the FIM in the control node.
4. Power up the cabinet.
5. Enter CDE mode on the maintenance terminal.
6. Select the Dimension and Feature Display form, and
ensure the maximum number of cabinets is selected for
your system configuration. For FD1 configurations
(non-redundant and SX-2000 MICRO LIGHT systems)
the number of cabinets should be set to 5. For FD2
configurations (redundant systems and 18”
non-redundant cabinets) the number of cabinets should
be set to 12.
7. If the maximum number of cabinets is selected, continue.
If the maximum number of cabinets is not selected,
proceed to page 18.
If the Maximum Number of Cabinets is Selected
1. Enter the Cabinet Assignment form.
2. For non-redundant and redundant LIGHT systems,
complete the Cabinet Assignment form as follows:
Type: Enter “FD Per” or “FD DSU”.
Cabinet: Assign cabinets with numbers 2 through 12.
Shelf: Enter 1.
Slot: Enter 17 for a peripheral cabinet. Enter 1 for DSU
cabinets with DSU cards in slots 2 or 3. Enter 6 for DSU
cabinets with DSU cards in slots 4 or 5.