5. Restore the database (see page 174).
After service is restored, enter the System Configuration
form and program the Peripheral Interface cards into the
new cabinet.
Redundant Systems
1. Save the database to RSD (see page 164).
2. Remove the RSD from the RSD drive.
3. Set ACTIVITY FREEZE to ON.
4. Enter PARTITION first from the active plane, then from
the inactive plane.
5. Enable options on the inactive plane (see page 197).
Enter 12 for the maximum number of cabinets in the
Dimension and Feature Select form.
6. Complete the Cabinet Assignment form.
7. Restore the database from RSD to the inactive plane
(see page 183).
The following step will interrupt service.
8. Press and hold the PANEL ENABLE button and press
the ACTIVITY SWITCH button.
9. Copy the software to the newly inactive plane and JOIN
the system (see page 193).
10.After service is restored, enter the System Configuration
form and program the Peripheral Interface cards into the
new cabinet.
11.Hold down PANEL ENABLE and press ACTIVITY
FREEZE OFF.