Technical information
Technician’s Handbook
20
Circuit Cards
Peripheral Interface Cards
Table 2:  Peripheral Interface Cards
Card Devices Supported Circuits Maximum Loop 
Resistance/LoopLengths
AC15 Trunk 
Card
AC15 trunk 8 not applicable
COV Line 
Card
SUPERSET™ 3 and 
SUPERSET 4 telephones
12  Loop resistance: 280 ohms
Loop length:
26 AWG (27 IWG) - 1000 m 
(3300 ft.)
24 AWG (25 IWG) - 1500 m 
(5000 ft.)
22 AWG (22 IWG) - 2000m 
(6000 ft.)
DID/Loop Tie 
Trunk Card, 
DID/2 Card
Direct Inward Dial (DID) 
trunks from CO
4 Loop resistance: 2450 ohms
Loop length:
26 AWG (27 IWG) - 7986 m 
(25955 ft.)
22 AWG (22 IWG) - 19995 m 
(64984 ft.)
DNI Line 
card
SUPERSET digital 
telephones
Datasets
Attendant Consoles
Programmable Key 
Modules
DNIC MOH/Paging Unit
16 Loop length:
24 AWG (25 IWG) - 1000 m 
(3300 ft.) including up to 50 m 
(162.5 ft.) 22 AWG (22 IWG) 
quad wire and up to 3 m modular 
line cord without bridge taps.
DTMF 
Receiver 
Card
DTMF telephone keypads 
and end-to-end signaling 
equipment.
16 not applicable
E&M Trunk 
Card
E&M tie trunk
Music on hold equipment 
Loudspeaker equipment
Paging equipment
4 not applicable
 (Sheet 1 of 2)