Technical information

Installation
27
Installation
DS1 Formatter Card Line Equalizer Switches
Set the line equalizer switches S1 and S2 as follows:
Note: The DS1 interface meets the AT&T DSX-1 specification for distances up to 655
feet (200 m) if 22 AWG (22 IWG) shielded cable is used. The interface can
operate at up to 750 feet (229 m), but compliance with the AT&T DSX-1 specifi-
cation is not guaranteed at this distance. For greater distances, a repeater must
be used.
CEPT Interface Assembly Jumpers
Jumper positions J06 to J09 allow you to ground the shields
of the coaxial cable connectors. Jumper positions J10 to J13
provide locations to affix the jumpers when they are not in
grounding positions. Jumpers J06, J07, J09, J011, and J12
are located beneath the side of the CEPT interface
assembly faceplate.
Note: Default settings are shown in bold.
Table 8: Line Equalizer Settings
Line Length Switch Cells
(feet) (meters)1234567
0 - 150 0 - 45.8 close open open open open open open
150 - 450 45.8 - 137.4 open close open open close open close
450 - 750 137.4 - 229 open open close close open close open
Table 9: CEPT Interface Assembly Connector Shield Grounding
Circuit 0
Circuit 1
RX grounded jumper across J06 RX grounded jumper across J08
RX not grounded no jumper across J06 RX not grounded no jumper across J08
TX grounded jumper across J07 TX grounded jumper across J09
TX not grounded no jumper across J07 TX not grounded no jumper across J09