Technical information
Maintenance Commands
87
Maintenance
Commands 
Busying Out a Card, Circuit, or Channel for Testing
BUsy <plid>
If the circuit is busy when you issue this command (indicated 
by "has an owner"), you have three options:
QUIT: leaves the circuit unbusied.
FORCE: cuts off the call in process and forces the circuit into 
manbusy.
COURTESY DOWN: waits for the call to end before placing 
the circuit into manbusy.
To return a busied circuit to service, enter RTS <plid>.
An extension parameter can also be used (BU EX 
<extension number>). System repsonse is the same 
whether an extension or a PLID is used.
Returning a Busy Circuit or Trunk to Service
RTS <plid>
or
RTS EX <extension number>
or
RTS TRUNK GROUP <group number> ALL
Removing a Courtesy Down Request
RCD <plid>
Removes a previous request to busy a peripheral circuit at 
the specified PLID. An extension parameter can also be 
used (RCD EX <extension number>). System response is 
the same whether an extension or PLID is used.










