Troubleshooting guide
Trunking
117
Embedded PRI
Embedded PRI calls 
fail and all Status 
LEDs on the Dual 
T1/E1 Framer are 
OFF.
Configuration. Verify that embedded PRI is programmed 
properly in the following forms (see also Program 
Embedded PRI/Q.SIG in the Online Help):
• Controller Module Configuration
• Dual T1/E1 Framer Configuration
• Link Descriptor Assignment
• Digital Link Assignment
After the Digital Links form is completed, the 
T1/E1 Framer status LEDs should come on. This 
takes about 15 seconds.
Embedded PRI Links 
are “not seizable”, 
Status LEDs show 
RED alarm.
Configuration or wiring. Ensure that the ISDN cable is plugged into the 
correct RJ-45 port on the Dual T1/E1 MMC. Verify 
that the ISDN cable is correctly wired.
Change the “Termination Mode” setting in the 
Digital Link Descriptors form - either LT or NT. 
This change takes about 30 seconds to take 
effect.
Embedded PRI links 
are “not seizable”, 
Status LEDs show 
flashing GREEN.
Configuration. Verify the “Network Side/QSIG Master” setting in 
the ISDN Protocol form. Check the “Inverted 
D-Channel” setting in the Digital Link Descriptors 
form - normally it is set to “No”. Each of these 
changes takes approximately 30 seconds.
Embedded DPNSS 
links are “not 
seizable”, Green LED 
is ON
Configuration. Ensure that the “Address for Message Control” 
field in the Digital Link Descriptors form is set 
appropriately (“A” or “B” depending on the far end.
If the configuration is correct, wait for about one 
minute until every circuit has finished negotiation 
with the far end.
Distorted voice or loud 
noise over PRI/QSIG 
call
Voice Encoding is not set properly. In the Link Descriptor Assignment for the 
PRI/QSIG trunk, set the “Voice Encoding” to Nil 
for T1 on NA or E1 on Euro controller.
Note: You cannot use the same Voice Encoding 
settings as a PRI NSU.
High number of slips. Configuration of Network 
Synchronization form.
Ensure that the synchronization source being 
selected is to a digital PSTN trunk (like PRI or 
T1/D4).
Outgoing calls fail with 
reorder tone.
Configuration error in ARS 
programming or ISDN Protocol 
form.
Enter the CCS TRACE maintenance command to 
ensure that the proper digits are being sent out.
Check the Digit Modification with the Per-Call 
programming for PRI to make sure digits are not 
being inserted or absorbed unnecessarily.
Ensure that the “Protocol” field in the ISDN 
Protocol form is correct for the PSTN link (not for 
DPNSS).
Table 34: Digital Trunk Troubleshooting
Symptom Probable Cause Corrective Action
Page 4 of 6