Troubleshooting guide

Hardware
49
DSU Cabinet
Microlight DSU cabinet
connected to a 3300 ICP via
Triple FIM -circuits 2 and 3 is
not functioning.
Microlight Peripheral Cabinet ia
not installed and connected to
Triple FIM -circuit 1.
If you connect a Microlight DSU cabinet to
the 3300 ICP via Triple FIM circuits 2 and
3, you must ensure that the Microlight
Peripheral Cabinet is connected to Triple
FIM circuit 1. Triple FIM circuit 1 provides
the clock source for all Triple FIM circuits.
Without circuit 1, there is no clock source
for other FIM circuits (2 and 3), resulting in
the internal DSU not working.
Also ensure that the Control Resource
Card (CRC) has not been removed from
the MicroLight cabinet.
Faulty PRI or BRI Card. Check external equipment and
connections.
Fix connections or replace cabling.
The connections between the
interface assembly and the
interface card.
Fix connections.
Faulty backplane cable
connections (or bent pins on
backplane and inside shelf).
Replace cable or straighten pins on
backplane.
Faulty programming. Check programming. Refer to the System
Administration Tool online help.
Faulty Interface Assembly. Replace Interface Assembly.
Defective card. Replace card.
Unable to establish a
connection between the IMAT
PC and the PRI or R2 card.
Faulty Dial-Up Networking
connection settings.
Check the Dial-Up Networking connection
settings.
Unable to fully insert a Triple
FIM card (Part Number
50001856) into the control slot
of Microlight cabinet. or
connect the Triple FIM to the
backplane.
The plastic tabs (stopper) were
improperly installed on the cards.
by the manufacturer preventing
proper installation.
Refer to Mitel Knowledge Base Article
08-5191-00105 for a solution.
Table 13: Peripheral Cabinet Troubleshooting
Symptom Probable Cause Corrective Action
Page 3 of 3