User's Manual

Installing
Release 3.3 125
Set the 3300 Controller IP Address
To set the 3300 Controller IP address:
1. Establish a serial connection from the 3300 Configuration Tool PC (or any PC equipped
with a communications program) to the Maintenance Port on the 3300 Controller.
2. Launch the communication program.
3. Set the RS-232 communication parameters:
Baud rate - 9600
Data bits - 8
•Parity - None
Stop bits - 1
Flow control - None
4. Connect AC power to the 3300 Controller.
5. Press the Reset button on the 3300 Controller with a small, pointed object.
6. Wait for the "Press any key to stop auto-boot" message and then press a key.
7. At VxWorks Boot, type c and then press Enter.
Press Enter after you enter the required text. For all other fields, (displayed in italics, for
information only) accept the default value or leave blank.
boot device: ata=0,0 (Boot device is Disk)
unit number: 0 (default, leave at 0, not used)
processor number: 0 (default, leave at 0, not used)
host name: (optional)
file name: /sysro/Rtc8260 (boot location and file name)
inet on ethernet (e): 134.199.63.11:ffffff00 (example RTC IP and subnet mask)
inet on backplane (b):
host inet (h):
gateway inet (g): 134.199.63.251 (example Router (Gateway)address)
user (u): ftp (must be ftp for Release 3.1)
ftp password (ftp) (blank = @):
flags (f): 0x0 (a fixed IP address (0x40 is used on E2T for DHCP)
target name (tn):
startup script (s):
other (o): motfcc (other device, E2T using Network to boot from)
Note: Type the IP address and subnet mask. The subnet mask must be in hexadecimal
format for the end user’s site (for example. ffffff represents 255.255.255.00).
Note: Enter the IP address of the end user's gateway for the 3300 Controller.