User's Manual

General Information Guide - Release 3.1
- 10
Specifications
Environment
Storage Environment for 3300 ICP Components and Peripherals
Condition Specification
Temperature 3300 Controller: 32º to 104º F (0º to 40º C)
All Other Components: 39º to 120ºF (4º to 49ºC)
Humidity 15-95% Relative Humidity, non-condensing
Vibration 0.5 g, 5 to 100 Hz, any orthogonal axis
1.5 g, 100 to 500 Hz, any orthogonal axis
Mechanical Stress
One 15.3 cm (6 in.) drop, each edge and corner adjacent to the rest
face unpackaged
One 76.2 cm (30 in.) drop, each edge and corner packaged in
cardboard & foam.
Operational Environment for 3300 ICP Components and Peripherals
Condition Specification
Temperature 3300 Controller: 59º to 95º F (15º to 35º C)
All Other Components: 39º to 120ºF (4º to 49ºC)
Humidity 3300 Controller: 40-90% Relative Humidity, non condensing
All Other Components: 34-95% Relative Humidity, non-condensing
Maximum Heat Dissipation -
fully loaded (see Note)
724 BTUs per hour
Air Flow 150 cubic feet per minute at maximum output of the fans
Acoustic Emissions Maximum 50 dBA continuous, 75 dB intermittent (<10% duty cycle)
Conversion factors: 1 watt is equal to 3.412 BTUs per hour, 1 ton of refrigeration is equal to 12,000
BTUs per hour or 3.516 Kilowatts, and 3/4 Kilowatt-hour is equal to 1 ton of refrigeration.