Step 3: Verify the iLink has been assigned at least one Connect-Back address.
a. Open a web browser and type the DHCP assigned or manually assigned Static IP address. If the NTL
Studio Utilities program is still open, then the “Congure IP” button can be clicked for the same result.
b. The unit’s built in web application will launch and display the current system settings.
c. Inspect the “Connect-Back Settings” - there should be at least one IP address assigned.
Example:
d. If all of these elds are blank then contact your dealer for assistance in entering this information.
e. If at least one eld has an IP address then continue to next step.
Step 4: Verify iLink can communicate with your dealers server.
a. Run the NTL Studio Utilities program from the CD.
b. Enter the Connect-Back Server IP Address (This is the address from the previous step).
c. Click on the “Test Connect-Back Server” button.
d. The status bar on the bottom of program will display a PASS or FAIL.
e. PASS will signify that the unit seems to be setup correctly on the network.
f. FAIL will signify that a rewall or other security setting is blocking trafc to the unit and that the
network administrator or dealer will need to get involved.
Connect-Back Settings
Connect-Back #1 71.181.88.130
Connect-Back #2 0 . 0 . 0 . 0
Connect-Back #3 0 . 0 . 0 . 0
Connect-Back #4 0 . 0 . 0 . 0