Heating performance Refrigerant leakage The heating performance values (kW) described in catalog are the values obtained by operating at an outdoor temperature of 7 C and indoor temperature of 20 C as set forth in the ISO Standards. As the heating performance decreases as the outdoor temperature drops, if the outdoor temperature is too low and the heating performance is insufficient, use other heating appliances as well.
4" ) History of Technologies more efficient , more sophisticated KX2 KX4 KX6 (8~12HP) 2
New Line Up Contents Introduction 4~13 Outdoor units 14~45 Indoor units 46~75 Control systems 76~80 Service and maintenance 81 High Head series 82~85 KX4 Outdoor units 86 .
" ) Product Line Up from 11.2kW up to 136.0kW(24models) Single use (1 Outdoor unit) Capacity Model Index : kW BTU / h kcal / h 4HP 11.2 38,200 9,630 5HP 14 47,800 12,040 6HP 15.5 52,900 13,330 8HP 22.4 76,400 19,260 10HP 12HP 14HP 16HP 18HP 20HP 22HP 24HP 28 33.5 40.0 45.0 50.4 56.0 61.5 68.
Wide variety of 16 types 78 models A range of 16 types of exposed or concealed indoor units, in wide capacities, 78 indoor models. The best selection of indoor units for many kinds of rooms and preference can be available from our full lineup.
1. High Efficiency (KX6) The industry's highest COP levels We have cleared the class A standard, the highest energy saving level, with our high COP (Coefficient Of Performance). EER in Cooling A COP in Heating CLASS COP 4.5 4.0 4.00 4.00 COP 4.5 4.33 4.0 3.46 3.41 3.55 3.47 3.42 3.34 3.36 3.29 3.5 3.2 A CLASS 3.6 4.15 3.84 3.71 3.84 3.82 3.74 3.75 3.71 3.72 3.5 3.0 3.0 2.5 2.
High efficiency and compact design are realized applying the various advanced functions 4~6HP(KX6) Compact High Efficient Heat Exchanger Compact high efficiency Heat Exchanger New Inverter Control Vector Inverter Control system • Optimizing relationship of the air flow velocity & fin pattern • Improvement of air distribution Maximizing efficiency of heat exchanger New Twin Rotary Compressor Heat Exchanger DC Fan Motor Compact & High efficiency KX4 KX6 Optimum New Refrigerant System Control 8~12HP
3D Scroll Compressor Unit start up speed in heating mode drastically improved for lower outdoor temperature operation. Lower at the inside Same height Higher at the outside Fixed scroll Downsizing High Efficiency High Endurance Orbital scroll High strength due to the lower teeth inside 3D scroll compressor has the different height scroll at the outside and the inside.
3. Design Flexibility Increased indoor unit connection capacity KX6 series(4~34HP) can connect indoor unit capacity up to 150~200% from 130% of previous models. If the connection capacity of indoor units is more than 100%, capacity of each indoor unit may be affected by connection capacity ratio.
R410A Long Pipe Length Piping length has extended max height difference between indoor units from 4m to 18m and enables us to put indoor unit on extra three floors. As a result of the adoption of thinner refrigerant piping and refrigerant volume reductions, the industry's longest 160 m actual piping length or 1000m total piping length is realized.
Wide Range of Operation KX6,KXR6 series permits a system design considering a heating range operation under a low temperature condition up to -20°C from -15°C of previous model and a cooling range operation under -15°C from -5°C of that. Heating NEW -20°C +15.5°C previous -15°C Cooling NEW -15°C -5°C +43°C previous -20 -10 0 10 20 30 40 For the capacities under low temperature conditions, refer to technical manual.
R410A Monitoring Function KX6 series includes new feature to assist with servicing and trouble shooting. Various data can be monitored through 3-digit or 6-digit display on the outdoor unit PCB. Detailed fault diagnosis and operation history memory via 7-segment display. 4~6HP Equipped with RS232C for connection directly to your PC monitoring and service tasks made simple with our service software (“Mente PC”).
heat pump systems KX6 heat pump systems operate with 2 inter-connecting pipes, thus commonly referred to as a '2-pipe system'. These systems provide either a heating or cooling operation to all indoor units and are suitable for a wide range of applications from an individual apartment (with "Micro KX", 1/phase system) to an entire multi storey building, especially where there are significant open plan areas to be controlled. The range starts with a 11.
4" ) Outdoor units Heat pump systems 4, 5, 6hp (11.2kW~15.5kW) Model No. FDC112KXEN6 FDC140KXEN6 FDC155KXEN6 FDC112KXES6 FDC140KXES6 FDC155KXES6 Blue Fin Nominal Cooling Capacity 11.2kW (1phase) 14.0kW (1phase) 15.5kW (1phase) 11.2kW (3phase) 14.0kW (3phase) 15.5kW (3phase) • The KX6 heat pump 2-pipe systems offer high performance VRF for applications that require either cooling only or heating only, ideal for open plan areas. • Connect up to 8 indoor units/up to 150% capacity.
Refrigerant piping Outdoor unit (HP) Gas pipe Liquid pipe 4 5 6 Branch pipes Header pipe DIS-22-1/DIS-180-1 HEAD6-180-1 ø15.88 Furthest indoor unit =<70m ø9.52 Dimensions All measurements in mm.
4" ) Outdoor units Heat pump systems 8, 10, 12hp (22.4kW~33.5kW) Model No. FDC224KXE6 FDC280KXE6 FDC335KXE6 Blue Fin Nominal Cooling Capacity 22.4kW 28.0kW 33.5kW • The KX6 heat pump 2-pipe systems offer high performance VRF for applications that require either cooling only or heating only, ideal for open plan areas. • Connect up to 22 indoor units/up to 150% capacity. • High efficiency with COP (in cooling) up to 4.0. • KX6 employs DC inverter compressors ONLY.
Refrigerant piping Outdoor unit (HP) Gas pipe Liquid pipe Gas pipe Liquid pipe 8 Furthest indoor unit =<90m ø19.05 Furthest indoor unit =<90m ø22.22 Branch pipes 10 12 ø22.22 ø28.58 ø9.52 Header pipe ø12.7 ø28.58 ø12.7 DIS-22-1/DIS-180-1 HEAD6-180-1 DIS-371-1 Dimensions All measurements in mm.
4" ) Outdoor units Heat pump systems 14, 16hp (40.0kW~45.0kW) Model No. FDC400KXE6 FDC450KXE6 Nominal Cooling Capacity 40.0kW 45.0kW Blue Fin • The KX6 heat pump 2-pipe systems offer high performance VRF for applications that require either cooling only or heating only, ideal for open plan areas. • Connect up to 40 indoor units/up to 200% capacity. • High efficiency with COP (in cooling) up to 3.6. • KX6 employs DC inverter compressors ONLY.
Dimensions All measurements in mm. J F I I Air intake J 352 158 530 148 410 342 235 G 1350 1690 797.8 126.2 720 22 174 720 240 295 G G 22 85 57 Anchor bolt positions for I 594 232 C F For dimensions of anchor bolt hole 234 80.5 71 H 120 I F 232 D(lower) 185 296.7 58.5 647 19 19 75 142.5 J 140 141 95 140.5 726 A Anchor bolt positions for F, J K B 74.5 250 175 F I J 58.
4" ) Outdoor units Heat pump systems 18, 20, 22, 24hp (50.4kW~68.0kW) Model No. FDC504KXE6 FDC560KXE6 FDC615KXE6 FDC680KXE6 Nominal Cooling Capacity 50.4kW 56.0kW 61.5kW 68.0kW Blue Fin • The KX6 heat pump 2-pipe systems offer high performance VRF for applications that require either cooling only or heating only, ideal for open plan areas. • Connect up to 49 indoor units/up to 160% capacity. • High efficiency with COP (in cooling) up to 3.4. • KX6 employs DC inverter compressors ONLY.
Dimensions All measurements in mm. 19 75 142.5 234 80.5 71 120 H 296.7 85 Air intake I I F J F For dimensions of anchor bolt hole 174 720 240 295 57 Anchor bolt positions for I 594 232 C G G 352 158 530 148 410 J 342 235 22 I F 232 D(lower) 185 22 74.5 J G 1350 2048 1155.8 126.2 720 F I 250 175 140 141 95 140.5 726 A J 58.5 19 B 647 K Anchor bolt positions for F, J Rear 58.
4" ) Outdoor units Heat pump combination systems 26, 28, 30, 32hp (73.5kW~90.0kW) Model No. FDC735KXE6 (FDC335-K+FDC400) FDC800KXE6 (FDC400x2) FDC850KXE6 (FDC400+FDC450) FDC900KXE6 (FDC450x2) Blue Fin Nominal Cooling Capacity 73.5kW 80.0kW 85.0kW 90.0kW • The KX6 heat pump 2-pipe systems offer high performance VRF for applications that require either cooling only or heating only, ideal for open plan areas. • Connect up to 65 indoor units/up to 160% capacity.
Dimensions All measurements in mm. J F I I F Air intake J 22 174 720 G 240 295 G 352 158 530 148 410 342 235 22 85 57 Anchor bolt positions for I 594 232 C 234 G 1350 1690 797.8 126.2 720 80.5 71 H 120 I F 232 D(lower) 185 296.7 58.5 647 19 19 75 142.5 74.5 J 140 141 95 140.5 726 A Anchor bolt positions for F, J K B 250 175 F I J 58.
4" ) Outdoor units Heat pump combination systems 34, 36, 38, 40, 42, 44, 46, 48hp (96.0kW~136.0kW) Model No. FDC960KXE6 (FDC450+FDC504) FDC1010KXE6 (FDC504x2) FDC1065KXE6 (FDC504+FDC560) FDC1130KXE6 (FDC560x2) FDC1180KXE6 (FDC560-K+FDC615) FDC1235KXE6 (FDC615x2) FDC1300KXE6 (FDC615+FDC680) FDC1360KXE6 (FDC680x2) Blue Fin Nominal Cooling Capacity 96.0kW 101.0kW 106.5kW 113.0kW 118.0kW 123.5kW 130.0kW 136.
Dimensions All measurements in mm. 19 75 142.5 232 D(lower) 185 80.5 71 296.7 120 H F I I F Air intake J 174 720 G 240 295 G 352 158 530 148 410 342 235 22 85 57 Anchor bolt positions for I 594 232 C J 22 74.5 J I F 234 G 1350 2048 1155.8 126.2 720 250 175 140 141 95 140.5 726 A F I J 58.5 19 B 647 K Anchor bolt positions for F, J Rear 58.
4" ) refrigerant piping Installation of Interconnecting Pipework Mitsubishi KX6 equipment is manufactured to the highest standards of quality and reliability. It is imperative the method of installation and the materials used are also to high standards, to ensure trouble free operation and long term reliability. The interconnecting pipework must be installed by a competent and trained engineer. Refrigeration quality copper tube must be used, soft copper coils or half-hard straight lengths.
refrigerant piping Outdoor unit (HP) Liquid pipe Gas pipe Liquid pipe Gas pipe 8 10 12 14 16 18 Furthest indoor unit =<90m ø9.52 ø12.7 ø19.05 ø22.22 ø28.58 Furthest indoor unit =>90m ø22.22 ø12.7 Branch pipes 20 22 Pipe sizes applicable to European installations. 24 26 28 30 32 34 36 38 ø15.88 40 42 44 46 48 ø19.05 ø34.92 ø15.88 ø19.05 ø28.58 ø22.22 ø34.92 mm inch ø9.52 3/8" mm inch ø28.58 11/8" 11/4" ø12.7 1/2" ø31.8 ø15.88 5/8" ø34.92 13/8" ø19.
R410A electrical wiring – power supply KX6 new design includes greatly simplified wiring requirements utilising a ‘polarity-free’ two wire control loop connecting the indoor units. Power wiring Cables can be laid through the front, right, left or bottom of the outdoor unit casing. Separate power supplies should be used for the outdoor unit (3/phase) and the indoor units (1/phase). Only control wiring is connected from outdoor to indoor unit.
electrical wiring – control wiring 1. The control wiring is 5 Volt DC, non-polarised, two wire connection notated as ‘A1’ and ‘B1’. This ‘AB’ wiring connects outdoor unit to indoor unit and indoor unit to indoor unit. 2. This wiring must be a 2-core shielded cable size 0.75mm2 or 1.25mm2. ~1000m 1000~1500m 0.75mm2 YES YES 1.25mm2 YES NO (1) When one outdoor unit is used Outdoor signal line terminal block Indoor signal line terminal block A1 A Indoor and outdoor signal line do not have a polarity.
4" ) heat recovery systems - for simultaneous heating and cooling KXR6 heat recovery systems operate with 3 inter-connecting pipes, thus commonly referred to as a '3-pipe system'. where the building orientation (N, S, E, W) can mean that heat gain/loss varies on each side of the building. KXR6 systems provide both heating and cooling operations to individual indoor units according to the room condition/requirement.
KXR6 heat recovery systems - for simultaneous heating and cooling The KXR6 system interconnecting pipework has a unique arrangement, with two of the interconnecting pipes routed through a PFD Distribution Controller, and the third pipe connected directly to each indoor unit from the main pipe run. This reduces installation time, and the number of brazed connections on site.
4" ) Outdoor units Heat recovery 3-pipe systems 8, 10, 12, 14, 16hp (22.4kW – 45.0kW) for simultaneous heating and cooling Model No. FDC224KXRE6 FDC280KXRE6 FDC335KXRE6 FDC400KXRE6 FDC450KXRE6 Nominal Cooling Capacity 22.4kW 28.0kW 33.5kW 40.0kW 45.0kW Blue Fin • The KXR6 heat recovery systems offer high performance VRF for almost every type of building, with the capacity for simultaneous heating and cooling operations of individual indoor units.
Dimensions All measurements in mm. Mark A B C D F G H K* L N Content 335-K 400 450 224 280 335 Refrigerant suction gas piping connection entrance ø19.05(Brazing) ø22.22(Brazing) ø25.4(Brazing) ø28.58(Brazing) Refrigerant liquid piping connection entrance ø9.52(Flare) ø12.7(Flare) Refrigerant discharge gas piping connection entrance ø15.88(Brazing) ø19.05(Brazing) ø22.22(Brazing) Power supply entry hole ø50(right . left . front),long hole 40x80(under side) Anchor bolt hole M10,4pcs.
4" ) Outdoor units Heat recovery 3-pipe systems 18, 20, 22, 24hp (50.4kW – 68.0kW) for simultaneous heating and cooling Model No. FDC504KXRE6 FDC560KXRE6 FDC615KXRE6 FDC680KXRE6 Blue Fin Nominal Cooling Capacity 50.4kW 56.0kW 61.5kW 68.0kW • The KXR6 heat recovery systems offer high performance VRF for almost every type of building, with the capacity for simultaneous heating and cooling operations of individual indoor units.
Dimensions All measurements in mm. Mark A B C D F G H K L N Content Refrigerant suction gas piping connection entrance Refrigerant liquid piping connection entrance Refrigerant discharge gas piping connection entrance Power supply entry hole Anchor bolt hole Drain waste water hose hole Drain hole Refrigerant oil equalization piping connection pipe Carrying in or hole for hanging Refrigerant piping exit hole 504 560 560-K 615 ø28.58(Brazing) ø12.7(Flare) ø22.22(Brazing) ø25.4(Brazing) ø50(right .
4" ) Outdoor units Heat recovery 3-pipe combination systems 26, 28, 30, 32hp (73.5kW – 90.0kW) for simultaneous heating and cooling Blue Fin Nominal Cooling Capacity 73.5kW 80.0kW 85.0kW 90.0kW Model No. FDC735KXRE6 (FDC335-K+FDC400) FDC800KXRE6 (FDC400x2) FDC850KXRE6 (FDC400+FDC450) FDC900KXRE6 (FDC450x2) • The KXR6 heat recovery systems offer high performance VRF for almost every type of building, with the capacity for simultaneous heating and cooling operations of individual indoor units.
Dimensions All measurements in mm. Mark A B C D F G H K* L N Content 335-K 400 450 Refrigerant suction gas piping connection entrance ø25.4(Brazing) ø28.58(Brazing) Refrigerant liquid piping connection entrance ø12.7(Flare) Refrigerant discharge gas piping connection entrance ø19.05(Brazing) ø22.22(Brazing) Power supply entry hole ø50(right . left . front),long hole 40x80(under side) Anchor bolt hole M10,4pcs. Drain waste water hose hole ø45,3pcs. Drain hole ø20,6pcs.
4" ) Outdoor units Heat recovery 3-pipe combination systems 34, 36, 38, 40, 42, 44, 46, 48hp (96.0kW – 136.0kW) for simultaneous heating and cooling Model No. FDC960KXRE6 (FDC450+FDC504) FDC1010KXRE6 (FDC504x2) FDC1065KXRE6 (FDC504+FDC560) FDC1130KXRE6 (FDC560x2) FDC1180KXRE6 (FDC560-K+FDC615) FDC1235KXRE6 (FDC615x2) FDC1300KXRE6 (FDC615+FDC680) FDC1360KXRE6 (FDC680x2) Blue Fin Nominal Cooling Capacity 96.0kW 101.0kW 106.5kW 113.0kW 118.0kW 123.5kW 130.0kW 136.
Dimensions All measurements in mm. Mark A B C D F G H K L N Content Refrigerant suction gas piping connection entrance Refrigerant liquid piping connection entrance Refrigerant discharge gas piping connection entrance Power supply entry hole Anchor bolt hole Drain waste water hose hole Drain hole Refrigerant oil equalization piping connection pipe Carrying in or hole for hanging Refrigerant piping exit hole 504 560 560-K 615 ø28.58(Brazing) ø12.7(Flare) ø22.22(Brazing) ø25.4(Brazing) ø50(right .
4" ) PFD refrigerant flow branch control Branch control PFD1123-E PFD1803-E PFD2803-E PFD1123X4-E Total downstream indoor unit capacity less than 11.2kW less than 18.0kW less than 28.0kW less than 44.8kW(11.
Dimensions All measurements in mm.
4" ) refrigerant piping Installation of Interconnecting Pipework Mitsubishi KXR6 equipment is manufactured to the highest standards of quality and reliability. It is imperative the method of installation and the materials used are also to high standards, to ensure trouble free operation and long term reliability. The interconnecting pipework must be installed by a competent and trained engineer. Refrigeration quality copper tube must be used, soft copper coils or half-hard straight lengths.
refrigerant piping Outdoor unit (HP) 8 10 12 14 16 Liquid pipe ø9.52 Furthest indoor unit ø19.05 ø22.22 =<90m Discharge Gas Pipe ø15.88 ø19.05 20 Suction Gas pipe Discharge Gas Pipe 26 ø19.05 28 30 32 34 36 38 ø15.88 40 42 44 46 ø19.05 48 mm inch mm inch ø9.52 3/8" ø28.58 11/8" ø12.7 1/2" ø31.8 11/4" ø34.92 ø15.88 5/8" ø34.92 13/8" ø22.22 ø28.58 ø19.05 3/4" ø38.1 11/2" ø22.22 7/8" ø44.5 13/4" ø25.4 1" ø50.8 2" ø15.88 ø22.22 ø15.88 24 ø28.58 ø12.
R410A electrical wiring – power supply KXR6 new design includes greatly simplified wiring requirements utilising a ‘polarity-free’ two wire control loop connecting the indoor units. Power wiring Cables can be laid through the front, right, left or bottom of the outdoor unit casing. Separate power supplies should be used for the outdoor unit (3/phase) and the indoor units (1/phase). Only control wiring is connected from outdoor to indoor unit.
electrical wiring – control wiring 1. The control wiring is 5 Volt DC, non-polarised, two wire connection notated as ‘A1’ and ‘B1’. This ‘AB’ wiring connects outdoor unit to indoor unit and indoor unit to indoor unit. 2. This wiring must be a 2-core shielded cable size 0.75mm2 or 1.25mm2. ~1000m 1000~1500m 0.75mm2 YES YES 1.25mm2 YES NO (1) When one outdoor unit is used Outdoor signal line terminal block Indoor signal line terminal block A1 A Indoor and outdoor signal line do not have a polarity.
4" ) Indoor units Ceiling Cassette -4wayFDT Model No. FDT28KXE6D FDT36KXE6D FDT45KXE6D FDT56KXE6D FDT71KXE6D Wired remote control RC-E4 (option) RCH-E3 (option) Wireless remote control FDT90KXE6D FDT112KXE6D FDT140KXE6D FDT160KXE6D RCN-T-36W-E (option) Individual flap control system The thinnest design According to room temperature conditions, four directions of air flow can be controlled by individual flap as preferred.
Dimensions All measurements in mm.
4" ) Ceiling Cassette -4way Compact (600x600mm)FDTC Fits into standard 600 x 600 ceiling Model No. FDTC22KXE6D FDTC28KXE6D FDTC36KXE6D FDTC45KXE6D FDTC56KXE6D Wired remote control RCN-TC-24W-ER (option) RCH-E3 (option) RC-E4 (option) Individual flap control system Wireless remote control Quiet operation (Sound level in the Lo mode.) According to room temperature conditions, four directions of air flow can be controlled by individual flap as preferred.
Dimensions All measurements in mm.
4" ) Ceiling Cassette -2wayFDTW Wired remote control FDTW28~56 Model No. FDTW28KXE6D FDTW45KXE6D FDTW56KXE6D RC-E4 (option) FDTW71KXE6D FDTW90KXE6D FDTW112KXE6D FDTW140KXE6D Wireless remote control FDTW71~140 Specifications Model Item Nominal cooling capacity kW Nominal heating capacity kW Power source Cooling Power consumption Heating kW Sound pressure level dB(A) Exterior dimensions mm HxWxD FDTW28KXE6D FDTW45KXE6D FDTW56KXE6D 2.8 3.2 4.5 5.0 5.6 6.
Ceiling Cassette -1wayFDTS Wired remote control RC-E4 (option) Model No.
4" ) Ceiling Cassette -1way CompactFDTQ Wired remote control Model No. FDTQ22KXE6D FDTQ28KXE6D FDTQ36KXE6D Fits into standard 600 x 600 ceiling RC-E4 (option) RCH-E3 (option) Wireless remote control RCN-KIT3-E (option) • Comfortable effective cooling for small rooms, with low fan speed air flow at just 5.4m3/min. Condensate drain pump included as standard 35 600 or less Optional wide panel shown for solid ceiling 210 63 285 295~325 Fresh air opening for ducting (Knock out) 250 Max.
Dimensions All measurements in mm.
4" ) Duct Connected -High Static PressureFDU Wired remote control RC-E4 (option) Model No. FDU71KXE6D FDU90KXE6D FDU112KXE6D FDU140KXE6D RCH-E3 (option) Wireless remote control Dimensions RCN-KIT3-E (option) All measurements in mm.
Duct Connected -High Static PressureFDU Model No. FDU224KXE6D FDU280KXE6D Wired remote control RC-E4 (option) Wireless remote control RCH-E3 (option) RCN-KIT3-E (option) Fan control kit (100~200Pa) U-FCRA(option) Dimensions All measurements in mm.
4" ) Duct Connected -Low/Middle Static PressureFDUM Model No.
FDUM28KXE6D, 36KXE6D, 45KXE6D, 56KXE6D FDUM71KXE6D, 90KXE6D FDUM112KXE6D, 140KXE6D 57
4" ) Duct Connected (thin) -Low Static PressureFDUT Model No. FDUT22KXE6D FDUT28KXE6D FDUT36KXE6D FDUT45KXE6D FDUT56KXE6D Wireless remote control Wired remote control RC-E4 (option) Suction guard set Duct air supply kit UT-FL1E(22,28,36) UT-FL2E(45,56) (option) *Filter pressure loss:5pa UT-DAS1E(22,28,36) UT-DAS2E(45,56) (option) RCH-E3 (option) RCN-KIT3-E (option) Using these kits, external static pressure of 35Pa for FDUT22/28/36KXE6D and 50Pa for FDUT45/56KXE6D can be attained.
Dimensions All measurements in mm. FDUT22KXE6D, 28KXE6D, 36KXE6D FDUT45KXE6D, 56KXE6D common to all models Space for installation and service Recommended way to install the unit The following way of installation is available. Refer to our technical manual for detail.
4" ) Duct Connected (Compact & Flexible) FDUH Wired remote control RC-E4 (option) Model No. FDUH22KXE6D FDUH28KXE6D FDUH36KXE6D RCH-E3 (option) Wireless remote control Drain up kit (600mm) UH-DU-E(option) Filter kit RCN-KIT3-E (option) UH-FL1E *Filter pressure loss:5pa Compact and thin size, light weight Quiet operation Our leading high technology has realized the best solution for air conditioning in hotels with compact and thin size units and high energy efficiency.
Dimensions 12-ø4 32 27.6 Holes for tapping screws 150 150 494 150 32.5 100 145 32.5 83.3 53 32 27.6 Symbol A B C1,C2 D E F (Duct dimension) 30.8 All measurements in mm. Supply air duct Content Model Gas piping Liquid piping Drain piping Hole for wiring Suspension bolts Inspection hole FDUH22KXE6D,28KXE6D ø9.52 (3/8") (Flare) ø6.35 (1/4") (Flare) FDUH36KXE6D ø12.7 (1/2") (Flare) VP20(I.D.20, O.D.
4" ) Wall Mounted FDK Wired remote control Model No. FDK22KXE6D FDK28KXE6D FDK36KXE6D FDK45KXE6D FDK56KXE6D FDK71KXE6D RC-E4 (option) FDK22~56 RCH-E3 (option) Wireless remote control RCN-K-E : FDK22~56 RCN-K71-E : FDK71 (option) FDK71 Installation Workability Innovative Design New FDK models adopt the air flow design that's proven to minimise resistance in a CFD analysis to achieve uniform air conditioning to the furthest corners of the room.
Dimensions All measurements in mm.
4" ) Ceiling Suspended FDE Wired remote control Model No. FDE36KXE6D FDE45KXE6D FDE56KXE6D FDE71KXE6D FDE112KXE6D FDE140KXE6D RC-E4 (option) Wireless remote control • Small • Light-weight • Quiet • Sleek, intelligent design RCN-E-E(option) New Slim Design Flap control system Selection of louver position is possible. Louvers can be set at different angles. RCH-E3 (option) Upper position 210mm Movable range is not applicable to *RCH-E3 the Flap control system.
Dimensions All measurements in mm. 10 D 145 410 52 108 40 53 109 990 215 210 173 40 Note) The slope of drain piping inside the unit must take decline of 10mm. B A 5 68 690 1070 195 60 15 20 C1,C2 235 Air supply 7 100 Drain hose piece (Accessory, 0.
4" ) Floor Standing -2wayFDFW Model No. FDFW28KXE6D FDFW45KXE6D FDFW56KXE6D Wireless remote control Wired remote control RC-E4 (option) RCH-E3 (option) RCN-FW-E Quiet Operation Sophisticated Design With classy semi flat front panel in chic white, the new series fit in various kinds of rooms and create relaxing atmosphere. Choice of wall hanging, floor standing or behind gallery installation is available.
Dimensions All measurements in mm.
4" ) Floor Standing (with casing) FDFL Floor Standing (without casing) FDFU Wired remote control RC-E4 (option) RCH-E3 (option) Wireless remote control RCN-KIT3-E (option) Model No.
Dimensions All measurements in mm.
Outdoor Air Processing unit FDU-F Wired remote control Model No. FDU500FKXE6D FDU850FKXE6D FDU1300FKXE6D FDU1800FKXE6D RC-E4 (option) RCH-E3 (option) Wireless remote control Fan control kit (100~200Pa) U-FCRB(option) RCN-KIT3-E (option) Air conditioning and intake of outdoor air are in the same system Outdoor Air processing unit can be connected in a KX6 system as one of indoor unit series and can create fresh and comfortable air supply together from our high advanced technology.
Connectivity with KX6 series FDU-F series are connectable to 8~48HP KX6 outdoor units, not connectable to 4~6HP. 8 ~ 48 HP : Yes , 4 ~ 6 HP : No Combination with KX6 series case In case OA processing units only Combination The total capacity of FDU-F is 50~100% of outdoor capacity A are connected with KX6 outdoor units and max quantity of FDU-F is 2 units. In case both of OA processing units B and dedicated air-conditioner are connected with KX6 outdoor unit.
R410A Specifications Model Item Nominal cooling capacity kW Nominal heating capacity kW Power source Cooling Power consumption Heating kW Sound pressure level dB(A) Exterior dimension mm HxWxD FDU500FKXE6D FDU850FKXE6D FDU1300FKXE6D FDU1800FKXE6D 9.0 4.2 14.0 7.0 22.4 10.9 28.0 14.8 0.11 0.11 38 0.16 0.16 41 0.27 0.27 43 0.31 0.31 46 360x820x830 360x1200x830 48 8.
FDU850FKXE6D Control box Duct connection port for outdoor air inlet 16-M5 screw Port for air outlet 12-M5 screw (Inner size of duct flange) (Inner size of duct flange) Suspension bolts pitch Suspension bolts pitch (Below suspension bolt pitch) Above or more or more Installation space or more Installation space Plan view (Inner size of duct flange) or more (Inner size of duct flange) Below Front view Installation space Symbol Slab or more Piping space (Service from side) or more Cei
4" ) Fresh Air Ventilation and Heat Exchange unit SAF-E4 Model No. SAF250E4 SAF350E4 SAF500E4 SAF800E4 SAF1000E4 Re; Building Regulations Part L2 The Part L2 (April 2006) regulations limit the amount of electrical/gas power to be used to provide heating or cooling in commercial buildings. Therefore the building designer needs to select energy efficient heating/cooling equipment, and to minimise energy losses through ventilation systems.
Dimensions All measurements in mm. SAF250E4,350E4,500E4 SAF800E4 SAF1000E4 Installation reference Ceiling Suspension Bolt Pipe Hood Outside Intake Duct Supply Air Duct SA (Supply Air) RA (Room Air) OA EA (Outside Air) Exhaust Air Room Intake Duct Heat Insulation Material Inside Supply Opening (Supply/Exhaust Air Grill) Room Intake Opening (Supply/Exhaust Air Grill) Exhaust Air Duct Unit:mm Dimension table NO.
Control Systems Remote Control line up indoor unit wired all models (except SAF) remote control RC-E4 wireless RCH-E3 indoor unit FDT FDTC FDE remote control RCN-T-36W-E RCN-TC-24W-ER RCN-E-E indoor unit FDK22~56 FDK71 others remote control RCN-K-E RCN-K71-E RCN-KIT3-E RC-E4 Run hour meters to facilitate maintenance checking RC-E4 stores operation data when an anomaly occurs and indicates the error on the LCD.
SUPERLINKMHI has now combined simplicity of installation with our highly sophisticated Superlink- control system, to offer building owners and occupiers a comprehensive control and management system, while providing complete commissioning and service maintenance assistance for installers and service engineers. The Superlink- network utilises two wire, non-polar cable - for further details of wiring.
4" ) SC-SL1N-E Start/stop control of up to 16 indoor units either individually or collectively. Example of control by a centre control SC-SL1N-E Simple centralised control. 1. The SC-SL1N-E is connected to the Superlinknetwork via 2-core, non-polar wires (‘AB’ connection). 2. It will monitor and control the start/stop function of up to 16 units, with the sixteen operation button. 3. The unit or group numbers in operation or in need of service are displayed with an LED. 4.
SC-SL3N-AE/BE Indoor unit 128 units MHI introduces the full colour touch screen central control SC-SL3NAE/BE, with 7 inch interactive LCD display. Offers control, monitoring, scheduling and service/maintenance functions for up to 128 indoor units. Indoor units can be controlled, scheduled, monitored and interrogated either individually, as groups or as blocks of groups with the following functions: SLA3R-BX Control Box (option) In case SC-SL3N-AE/BE is fixed in the wall, use SLA3R-BX as optional parts.
R410A SC-WGWNA-A/SC-WGWNA-B Production by order (SC-WGWNA-B is with electric power calculation function) Control and monitoring of up to 96 cells (some cells can have two or more indoor units and total number of indoor units can be up to 128 units) centralised to a network PC using the Superlink- web gateway. Simple installation is assured with no special software requirements, operation is via Internet Explorer.
Service/maintenance and monitoring The design of the outdoor units separates the air flow compartment from the mechanical compartment, allowing easy access to serviceable parts by simply removing the panel. This design also means that the base plate of the air flow compartment acts as a drain tray connected to a drain pipe that runs through the mechanical compartment, so a simple connection of a drain hose to the base of the unit is all that is required, no need for a separate drain tray to be installed.
Outdoor units High Head series ( 00m) 14~48hp (40.0~136.0kW) Model No. FDCH335KXE6-K FDCH400KXE6 FDCH450KXE6 FDCH504KXE6 FDCH560KXE6 FDCH560KXE6-K FDCH615KXE6 FDCH680KXE6 Coming soon Production by order Nominal Cooling Capacity 33.5 kW 40.0 kW 45.0 kW 50.4 kW 56.0 kW 56.0 kW 61.5 kW 68.0 kW Model No.
Specifications Item Nominal horse power Power source Nominal capacity Electrical characteristics Exterior dimensions Net weight Refrigerant charge Sound pressure level Refrigerant piping size Model Cooling Heating Starting current Cooling Power consumption Heating Cooling Running current Heating HxWxD R410A Cooling / Heating Liquid line Gas line Capacity connection Number of connectable indoor units Item kW kW A kW kW A A mm kg kg dB(A) mm(in) Exterior dimensions Net weight Refrigerant charge Refrige
4" ) Dimensions All measurements in mm. FDCH335KXE6-K, 400KXE6, 450KXE6 J F I I Air intake J 352 158 530 148 410 342 235 G 1350 1690 797.8 126.2 720 22 174 720 240 295 G G 22 85 57 Anchor bolt positions for I 594 232 C F For dimensions of anchor bolt hole 234 80.5 71 H 120 I F 232 D(lower) 185 296.7 58.5 647 19 19 75 142.5 J 140 141 95 140.5 726 A Anchor bolt positions for F, J K B 74.5 250 175 F I J 58.
Dimensions All measurements in mm. FDCH504KXE6, 560KXE6, 560KXE6-K, 615KXE6, 680KXE6 19 75 142.5 234 80.5 71 120 H 296.7 85 Air intake I I F J F For dimensions of anchor bolt hole 174 720 240 295 57 Anchor bolt positions for I 594 232 C G G 352 158 530 148 410 J 342 235 22 I F 232 D(lower) 185 22 74.5 J G 1350 2048 1155.8 126.2 720 F I 250 175 140 141 95 140.5 726 A J 58.5 19 B 647 K Anchor bolt positions for F, J Rear 58.
KX4 R410A KX4 Outdoor units Heat pump systems 8, 10, 12hp (22.4kW~33.5kW) Model No. FDCA224HKXE4D FDCA280HKXE4D FDCA335HKXE4D Production by order Nominal Cooling Capacity 22.4kW 28.0kW 33.5kW • Superlink models (not Superlink- models) • The KX4 heat pump 2-pipe systems offer high performance VRF Uniform footprint of all models allows continuous side-by-side installation for applications that require either cooling only or heating only. • Connect up to 20 indoor units/up to 130% capacity.
Dimensions All measurements in mm. J F I I F Air intake J 22 174 720 240 295 G G 352 158 530 148 410 342 235 22 85 57 Anchor bolt positions for I 594 232 C 234 G 1350 1690 797.8 126.2 720 80.5 71 H 120 I F 232 D(lower) 185 296.7 58.5 647 19 19 75 142.5 J 140 141 95 140.5 726 A Anchor bolt positions for F, J K B 74.5 250 175 F I J 58.
4" ) Mitsubishi Heavy Industries /further information Mitsubishi Heavy Industries operates a continuous CSR (Corporate Social Responsibility) policy, with a role to realise a sustainable society through it’s various areas of business. Creed • We strongly believe that the customer comes first and that we are obliged to be an innovative partner to society. • We base our activities on honesty, harmony, and a clear distinction between public and private life.
The KX6 product range has been developed in compliance with the Mitsubishi Heavy Industries Policy on the Environment. In order to make the sustainable development of society possible, a basic policy on environmental matters has been established.
global activity On the land and sea, in the sky and even in space, MHIís stage of operations is expanding limitlessly. We manufacture more than 700 different products which support various industrial and civil activities in both domestic and international markets.
• Chemical Plants • Wind Tunnel/Experiment Equipment • Casting Machines • Strip Mill • Cement Plant • Stepless Variable Speed Gears • Industrial Robots • Injection Moulding Machines • Pulp & Paper Machinery • Corrugation Machines • Box Making Machines • Machine Tools • Ceiling Recess Packaged Air Conditioners • Automotive Air Conditioners • Residential Use Split Air Conditioners • Refrigeration Units • Dry Cleaning Machines • Food Machinery • Cruise Ships • Multi-purpose Dome • Stage Machinery Systems • C
Heating performance Refrigerant leakage The heating performance values (kW) described in catalog are the values obtained by operating at an outdoor temperature of 7 C and indoor temperature of 20 C as set forth in the ISO Standards. As the heating performance decreases as the outdoor temperature drops, if the outdoor temperature is too low and the heating performance is insufficient, use other heating appliances as well.