Specifications
Model No.
FDC960KXE6 (FDC450+FDC504)
FDC1010KXE6 (FDC504x2)
FDC1065KXE6 (FDC504+FDC560)
FDC1130KXE6 (FDC560x2)
FDC1180KXE6 (FDC560-K+FDC615)
FDC1235KXE6 (FDC615x2)
FDC1300KXE6 (FDC615+FDC680)
FDC1360KXE6 (FDC680x2)
Nominal Cooling Capacity
96.0kW
101.0kW
106.5kW
113.0kW
118.0kW
123.5kW
130.0kW
136.0kW
Heat pump combination systems
34, 36, 38, 40, 42, 44, 46, 48hp (96.0kW~136.0kW)
Item
Combination (FDC)
Nominal horse power
Power source
Nominal capacity
Electrical characteristics
Exterior dimensions
Net weight
Refrigerant charge
Refrigerant piping size
Capacity connection
Number of connectable indoor units
Cooling
Heating
Starting current
Power
consumption
Running
current
HxWxD
R410A
Liquid line
Gas line
Cooling
Heating
Cooling
Heating
kW
A
kW
A
mm
kg
kg
mm(in)
%
FDC960KXE6
Range of operation
Outdoor unit
Total length: 1000m
To the
first branch:
max 130m
From the first
branch to the
furthest indoor
unit: 90m
Height difference
50m
(outdoor unit above)
40m
(outdoor unit below)
Furthest
indoor unit: 160m
Max height
difference
between
indoor units:
18m
Indoor unit
Indoor unit
Indoor unit
3 Phase 380-415V, 50Hz
16
2048x2700x720
11.5x2
ø34.92(1 3/8")
The KX6 heat pump 2-pipe systems offer high performance VRF for applications that
require either cooling only or heating only, ideal for open plan areas.
Connect up to 80 indoor units/up to 130% (960KXE6:160%) capacity.
High efficiency with COP (in cooling) up to 3.5.
KX6 employs DC inverter compressors ONLY.
Industry leading total piping length up to 1000m and a maximum pipe run of 160m.
450KXE6
504KXE6
34HP
96.0
108.0
27.70
28.22
45.2-41.3
46.9-43.0
341+317
50~160
69
FDC1010KXE6
504KXE6
504KXE6
36HP
101.0
113.0
29.46
30.24
48.2-44.0
50.4-46.2
59
FDC1065KXE6
504KXE6
560KXE6
38HP
106.5
119.5
31.52
31.91
51.5-47.1
53.2-48.8
341x2
62
FDC1130KXE6
560KXE6
560KXE6
40HP
113.0
127.0
33.58
33.58
54.8-50.2
56.0-51.4
66
FDC1180KXE6
560KXE6-K
615KXE6
42HP
118.0
132.0
37.16
35.27
60.5-55.4
58.7-53.8
50~130
69
FDC1235KXE6
615KXE6
615KXE6
44HP
123.5
138.0
40.74
36.96
66.2-60.6
61.4-56.2
72
FDC1300KXE6
615KXE6
680KXE6
46HP
130.0
142.0
45.35
37.56
73.4-67.2
62.3-57.1
76
FDC1360KXE6
680KXE6
680KXE6
48HP
136.0
146.0
49.96
38.16
80.6-73.8
63.2-58.0
80
ø15.88(5/8")
ø19.05(3/4")
185
50
40
30
20
10
0
-10
-20
Heating
Cooling
+43
°
C
-15
°
C
+15.5
°
C
-20
°
C
Model
1. The data are measured under the following conditions(ISO-T1). Cooling: Indoor temp. of 27°CDB, 19°CWB, and outdoor temp. of 35°CDB. Heating: Indoor temp. of 20°CDB, and outdoor temp. of 7°CDB, 6°CWB. Piping length is 7.5m.
2. Sound pressure level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.
Outdoor units
355x2