User`s manual

32
Range of operation
Model No.
FDC224KXRE6
FDC280KXRE6
FDC335KXRE6
FDC400KXRE6
FDC450KXRE6
Nominal Cooling Capacity
22.4kW
28.0kW
33.5kW
40.0kW
45.0kW
Heat
recovery 3-pipe systems 8, 10, 12, 14, 16hp
(22.4kW – 45.0kW)
Outdoor unit
Total length:1000m
To the
first branch:
max 130m
From the first
branch to the
furthest indoor
unit: 90m
Height difference
50m
(outdoor unit above)
40m
(outdoor unit below)
Furthest
indoor unit: 160m
Max height
difference
between
indoor units:
18m
Indoor unit
Indoor unit
Indoor unit
for simultaneous heating and cooling
•
The KXR6 heat recovery systems offer high performance VRF for almost
every type of building, with the capacity for simultaneous heating and
cooling operations of individual indoor units. Energy efficiency is
maximised by employing DC inverter compressors ONLY, and distributing
surplus heat from cooling operations to areas where it is required (and
vice versa) resulting in COP (in cooling) from 3.7 to 4.2.
•
Connect from 50% up to 200% capacity indoor units.
•
Industry leading total piping length up to 1000m and a maximum pipe run
of 160m.
50
40
30
20
10
0
-10
-20
Heating
Cooling
+43
°
C
-15
°
C
+15.5
°
C
-20
°
C
Uniform footprint of all models (from
8hp~24 hp) allows continuous side-
by-side installation
8
Item
Nominal horse power
Power source
Nominal capacity
Electrical characteristics
Exterior dimensions
Net weight
Refrigerant charge
Sound pressure level
Refrigerant piping size
Capacity connection
Number of connectable indoor units
Cooling
Heating
Starting current
Power
consumption
Operating
current
HxWxD
R410A
Cooling/Heating
Liquid line
Suction Gas line
Discharge Gas line
Cooling
Heating
Cooling
Heating
kW
A
kW
A
mm
kg
kg
dB(A)
in (mm)
%
8HP
22.4
25.0
5.90
5.90
9.1-8.3
9.2-8.4
8.7
57/57
ø19.05(3/4”)
ø15.88(5/8”)
20
FDC224KXRE6
10HP
28.0
31.5
5
8.46
8.46
13.5-12.3
13.4-12.3
9.9
58/59
25
FDC280KXRE6 FDC335KXRE6 FDC400KXRE6 FDC450KXRE6
ø9.52(3/8”)
252
ø25.4(1”) [ø22.22(7/8")]
ø19.05(3/4”)
12HP
3 Phase 380-415V, 50Hz
33.5
37.5
9.98
9.55
15.9-14.8
15.5-14.2
1690x1350x720
256
11.4
62/63
50~200
30
14HP
40.0
45.0
11.61
11.93
19.0-17.4
19.9-18.2
60/60
ø12.7(1/2”)
36
337
11.5
ø25.4(1”) [ø28.58(1 1/8")]
ø22.22(7/8”)
16HP
45.0
50.0
13.49
13.32
21.6-19.8
22.0-20.1
62.5/62.5
40
Specifications
1. The data are measured under the following conditions(ISO-T1). Cooling: Indoor temp. of 27°CDB, 19°CWB, and outdoor temp. of 35°CDB. Heating: Indoor temp. of 20°CDB, and outdoor temp. of 7°CDB, 6°CWB. Piping length is 7.5m.
2. Sound pressure level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.
3. [ ] : Pipe sizes applicable to European installations are shown in parentheses.
Outdoor units