User`s manual

48
Ceiling Cassette -4way Compact (600
x
600mm)-
FDTC
Model No.
FDTC22KXE6D
FDTC28KXE6D
FDTC36KXE6D
FDTC45KXE6D
FDTC56KXE6D
Quiet operation (Sound level in the Lo mode.)
“CLEARER”AIR FLOW
New shape & angled louvre re-directs the air
current away from the ceiling, to reduce ceiling
stains.
Hi:35 Me:33 Lo:30
Hi:35 Me:33 Lo:32
Hi:9.5 Me:8.5 Lo:7
Hi:9.5 Me:8.5 Lo:8
Hi:10 Me:9 Lo:7
Hi:10 Me:9 Lo:8
Unit:14 Panel:3.5 Unit:15 Panel:3.5
FDTC22KXE6D
2.2
2.5
FDTC28KXE6D
2.8
3.2
FDTC36KXE6D
3.6
4.0
Hi:38 Me:36 Lo:31
Hi:38 Me:36 Lo:34
FDTC45KXE6D
4.5
5.0
Hi:40 Me:37 Lo:31
Hi:40 Me:37 Lo:34
Hi:11 Me:9 Lo:7
Hi:11 Me:9 Lo:8
FDTC56KXE6D
5.6
6.3
Hi:45 Me:39 Lo:31
Hi:45 Me:39 Lo:34
Hi:13 Me:10 Lo:7
Hi:13 Me:10 Lo:8
1 Phase 220-240V, 50Hz
kW
kW
kW
dB(A)
mm
kg
CMM
mm(in)
Item
Nominal cooling capacity
Nominal heating capacity
Power source
Power
consumption
Sound pressure
level
Exterior dimensions
H x W x D
Net weight
Air flow
Outside air intake
Panel
Air filter, Q’ty
Remote control(option)
Installation data
Refrigerant piping size
Unit:248x570x570 Panel:35x700x700
Not possible
TC-PSA-25W-E
Pocket Plastic net x1 (Washable)
wired:RC-E4, RCH-E3 wireless:RCN-TC-24W-ER
Liquid line:ø6.35(1/4")
Gas line:ø9.52(3/8")
Liquid line:ø6.35(1/4")
Gas line:ø12.7(1/2")
Model
Cooling
Heating
Cooling
Heating
Cooling
Heating
0.03-0.03
0.03-0.03
0.04-0.04
0.04-0.04
Specifications
1. The data are measured under the following conditions(ISO-T1). Cooling: Indoor temp. of 27°CDB, 19°CWB, and outdoor temp. of 35°CDB. Heating: Indoor temp. of 20°CDB, and outdoor temp. of 7°CDB, 6°CWB.
2. Sound pressure level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.
For wireless control simply insert
the infra-red receiver kit on a
corner of the panel.
Installation Workability
Fits into standard
600 x 600 ceiling
Current
(Cooling/Heating)
New
(Cooling)
New
(Heating)
32
dB
30
dB
32
dB
FDTC22KX, 28KX
2dB
Down
36
35
34
33
32
31
30
29
28
27
26
25
(dB)
Current
(Cooling/Heating)
New
(Cooling)
New
(Heating)
34
dB
31
dB
34
dB
FDTC36KX
3dB
Down
36
35
34
33
32
31
30
29
28
27
26
25
(dB)
Current
(Cooling/Heating)
New
(Cooling)
New
(Heating)
36
dB
31
dB
34
dB
FDTC45KX
5dB
Down
2dB
Down
40
39
38
37
36
35
34
33
32
31
30
29
28
27
26
25
(dB)
Current
(Cooling/Heating)
New
(Cooling)
New
(Heating)
39
dB
31
dB
34
dB
FDTC56KX
5dB
Down
8dB
Down
40
39
38
37
36
35
34
33
32
31
30
29
28
27
26
25
(dB)
According to room temperature conditions, four directions of air flow
can be controlled by individual flap as preferred.
As individual flap control is available even after installation,
installation area became wider than before.
Individual flap control system
Wireless remote control
RCN-TC-24W-ER
(option)
RC-E4
(option)
Wired remote control
RCH-E3
(option)
Selection of louver position is
possible. Louvers can be set at
different angles.
Upper
position
Movable
range
Lower
position
Flap control system
*
RCH-E3 is not applicable to the Individual flap
control system and the Flap control system.
Powerful-Hi can be selected. Sound pressure level: FDTC22/28 44dB(A), FDTC36 46dB(A), FDTC45 48dB(A), FDTC56 49dB(A). Air flow: FDTC22/28 12CMM, FDTC36 13CMM, FDTC45 15CMM. FDTC56 16CMM.