User`s manual

60
Duct Connected (Compact & Flexible)
FDUH
Model No.
FDUH22KXE6D
FDUH28KXE6D
FDUH36KXE6D
Compact and thin size, light weight
Our leading high technology has realized the
best solution for air conditioning in hotels with
compact and thin size units and high energy
efficiency. In addition, weight is only 20kg.
Quiet operation
The lowest sound level in the industry can ensure
comfortable stay and rest in hotels.
Installation Flexibility
Control box and drain piping can be installed on both side of the unit and air intake
to the unit is available from bottom or back side. Our highest technology can satisfy
diverse installation requirements.
RCH-E3
(option)
Wired remote control
Simple remote control
Considering specialized
usage in hotel rooms,
control buttons are limited
only to minimum required
functions such as ON/OFF,
mode, temperature setting
and fan speed. It is really
simple and easy to use.
257
mm
570mm
530mm
Control box
Drain piping
Specifications
2.2
2.5
2.8
3.2
3.6
4.0
Gas line:ø12.7(1/2")Gas line:ø9.52(3/8")
1 Phase 220-240V, 50Hz
0.05-0.07
0.05-0.07
HI: 33 Me: 30 Lo: 27
257x570x530
22
HI: 7 Me: 6.5 Lo: 6
30
Not possible
Procure locally
wired:RC-E4,RCH-E3 wireless:RCN-KIT3-E
kW
kW
kW
dB(A)
mm
kg
CMM
Pa
mm(in)
Nominal cooling capacity
Nominal heating capacity
Power source
Power
consumption
Sound pressure level
Exterior dimensions HxWxD
Net weight
Air flow
External static pressure
Outside air intake
Air filter, Q'ty
Remote control(option)
Installation data
Refrigerant piping size
Model
FDUH22KXE6D FDUH28KXE6D FDUH36KXE6D
Cooling
Heating
1. The data are measured under the following conditions(ISO-T1). Cooling: Indoor temp. of 27°CDB, 19°CWB, and outdoor temp. of 35°CDB. Heating: Indoor temp. of 20°CDB, and outdoor temp. of 7°CDB, 6°CWB.
2. Sound pressure level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.
Item
Drain up kit
(600mm)
UH-DU-E(option)
RC-E4
(option)
Wired remote control
RCH-E3
(option)
Wireless remote control
RCN-KIT3-E
(option)
Filter kit
UH-FL1E
*
Filter pressure loss:5pa
Liquid line:ø6.35(1/4")Liquid line:ø6.35(1/4")
Powerful-Hi can be selected. Sound pressure level: FDUH22/28/36 39dB(A). Air flow: FDUH22/28/36 8.5CMM.