Cell
<
BMS interface unit
>
SC-BGWN-A/SC-BGWN-B (BACnet gateway)
<
PC windows
central control
>
SC-WGWNA-A/SC-WGWNA-B
(SC-WGWNA-B is with electric power calculation function)
PC requirements: Windows 2000 or Windows XP.
Monitor resolution 1024 x 768.
Web browser requirements: Internet Explorer 6.0 or 7.0.
64 units
Ethernet 10 BASE-T/100BASE-TX
BACnet I/P Protocol.
Network
for
lighting
Emergency
sensor
network
SC-ADNA-E
64 units
48 cells
48 cells
Ethernet 10 BASE-T/
100BASE-TX
64 units
64 units
48 cells
48 cells
Internet
Explorer
HUB
P1
pulse
P2
P3
P4
SC-LGWN-A (LonWorks gateway)
LonWorks network
(FTT-10)
48 units
48 units
Network
for
lighting
Emergency
sensor
network
Additional engineering service cost etc. is required.
Please consult your dealer when using this central control.
Additional engineering service cost etc. is required.
In case of SC-BGWN-B, communication test by
qualified person regarding electric cost calculation
function is required before commissioning.
Please consult your dealer when using this gateway.
Additional engineering service cost etc. is required.
Please consult your dealer when using this gateway.
SC-ADNA-E
SC-ADNA-E
SUPERLINK- No. 1 system
SUPERLINK- No. 2 system
SUPERLINK- No. 1 system
SUPERLINK- No. 2 system
SUPERLINK- No. 1 system
SUPERLINK- No. 2 system
SC-LGWN-A is an interface device that converts MHI’s Superlink- communication data to LonWorks code.
Control and monitoring functions of the a/c system for up to 96 indoor units can be integrated to a central
control point via the building management system network.
Control and monitoring of up to 96 cells (some cells can have two or more indoor units and total number of
indoor units can be up to 128 units) centralised to a network PC using the Superlink- web gateway. Simple
installation is assured with no special software requirements, operation is via Internet Explorer. A low power
embedded CPU and compact flash ROM ensure a large storage capacity with high reliability (no moving parts
such as a PC fan, etc). An IP address filter function combined with three-level user authentication check also
ensures security.
(SC-BGWN-B is with electric power calculation function)
SC-BGWN-A/B is an interface device that converts MHI’s Superlink- communication data to BACnet code.
Control and monitoring functions of the a/c system for up to 96 cells (some cells can have two or more indoor
units and total number of indoor units can be up to 128 units) can be integrated to a central control point via
the building management system network.
Watt meter pulse input
(in case of SC-WGWNA-B)
P1
pulse
P2
P3
P4
Watt meter pulse input
(in case of SC-BGWN-B)