Specifications

4- 19
4. REPLACEMENT FROM A-MOTION TO QN-MOTION
3.2.5 Special relay
Device number
Name Remarks
Q17nCPUN
A17nSHCPUN/
A173UHCPU
M2320 M9000 M9000 Fuse blown detection flag
- M9002 I/O module verification error
- M9004 MINI link error A173UHCPU only
M2321 M9005 M9005 AC DOWN detection flag Q17nCPUN: AC/DC DOWN detection
M2322 M9006 M9006 Low battery flag
M2323 M9007 M9007 Low battery latch flag
M2324 M9008 M9008 Self diagnosis error flag
- M9009 Annunciator detection
M2325 M9010 M9010 Diagnosis error flag
- M9011 Operation error flag
- M9012 Carry flag
- M9016 Data memory clear flag (all data)
- M9017 Data memory clear flag (non-latch data)
- M9020 User timing clock No.0
- M9021 User timing clock No.1
- M9022 User timing clock No.2
- M9023 User timing clock No.3
- M9024 User timing clock No.4
M3136 M9025 M9025 Clock data set requirement
M2328 M9026 M9026 Clock data error
- M9027 Clock data display
M3137 M9028 M9028 Clock data reading requirement
- M9029 Data communication requirement batch processing
- M9030 0.1 second clock
- M9031 0.2 second clock
- M9032 1 second clock
- M9033 2 second clock
- M9034 1 minute clock
M2326 M9036 M9036 Always ON
M2327 M9037 M9037 Always OFF
- M9038 Only 1 scan is ON after RUN
- M9039 RUN flag (only 1 scan is OFF after RUN)
- M9040 PAUSE enabled coil
- M9041 PAUSE status contact
- M9042 Stop status contact
- M9043 Sampling trace completion
- M9044 Sampling trace
- M9045 Reset watchdog timer (WDT)
- M9046 Sampling trace A173UHCPU only
- M9047 Sampling trace preparation A173UHCPU only
- M9049 Switch output characters number
- M9051 CHG command execution inhibition A173UHCPU only
- M9052 Switch SEG command
- M9053 Switch EI/DI command
- M9054 STEP RUN flag
- M9055 Status latch completion flag
* Q17nCPUN has only four blocks for automatic refresh. If the number of blocks is insufficient, change the device numbers of special relays
to M2000s and use them.