Instruction manual

••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••
18
Specifications
General
Rated Power Supply: 100 to 240 V AC ±10 %, 50/60 Hz
Rated Input: 0.7 - 0.4 A (100-240 V)
Operating Temperature: 41 °F-104 °F (5 °C to 40 °C)
Relative Humidity: Max. 80 (%)
Altitude: Max. 2000 (m)
Dimensions: 424 (Width) x 361 (Depth) x 49 (Height) (mm)
Weight: 5 kg
Control terminals
CONT IN Input terminal working with the power supply of the recorder
CONT OUT Output terminal working with the power supply of the recorder
GND (Ground) For grounding
TEMP ALM Output terminal for detecting abnormality of temperature (open collector output)
Active: Low Level Max. Drive current 7 mA DC.
Non active: Open. Max. Voltage 24 V DC.
FAN ALM Output terminal for detecting abnormality of the fan (open collector output)
Active: Low Level Max. Drive current 7 mA DC.
Non active: Open. Max. Voltage 24 V DC.
EXTERNAL CONTROL:
When set to ON: Power is supplied to the HDD when 12V of voltage is applied to the input terminal working with
the power supply
When set to OFF: Power is always supplied to the HDD.
Serial bus terminal
Serial bus terminal (2 terminals) (Only DX-ZD5UE(Z) is connectable.)
Accessories: USB2.0 cable 1
Screws 8
Users manual (this manual) 1
Power cord 3
Control input/output terminals and circuits
<Interface circuit inside the unit>
Output terminal
GND terminal
TEMP ALM terminal
FAN ALM terminal
Output Circuit
Design and specifications are subject to change without notice.