Instruction manual

36
Test Running
<Operation procedure>
1) Set the station number of the inverter to be run and the operation mode (PU or LNK (Link) operation).
2) Confirmation of the auto tuning parameters
Clicking the [Check] button (Alt+C) shows the parameters on the screen in a dialog box.
After entering all parameter set values, click the [Blk
Write] button to write the new parameter values to the
inverter.
3) Click the [FWD
] (Alt+D) or [REV] (Alt+R) button.
The LED block and monitor screen display the auto tuning status.
When Pr. 96 = "101", the motor is rotated. The motor stops on completion of auto tuning. If the auto tuning
has failed, follow the dialog box instructions.
CAUTION
1. In the offline mode, test running and auto tuning cannot be performed.
2. Before starting test running, check and if necessary adjust the parameters. Not doing so may cause
some machines to perform unexpected operation.
3. Provide safety backup devices such as emergency brakes to ensure that the machinery and equip-
ment are not put in hazardous conditions if the inverters become faulty.
4. Auto tuning is not available for the FR-F500 series and FR-S500 series. (Can be displayed on the
screen.)