PARAMETERS
<Setting of stall prevention operation level>
In Pr. 22, set the stall prevention operation level. Normally set it to 150% (factory
setting). Set "0" in Pr. 22 to disable the stall prevention operation.
To reduce the stall prevention operation level in the high-frequency range, set the
reduction starting frequency in Pr. 66 and the reduction ratio compensation factor in
Pr. 23.
Formula for stall prevention operation level
Stall prevention operation level (%) = A + B × [] × []
where, A = , B =
By setting "9999" (factory setting) in Pr. 23, the stall prevention operation level is
constant at the Pr. 22 setting up to 400Hz.
<Setting of stall prevention operation selection>
Refer to the following table and set the parameter.
Pr. 156
Setting
Fast-
Response
Current
Limit
{: Activated
z: Not
activated
Stall Prevention
Operation
Selection
{: Activated
z: Not activated
OL Signal
Output
{:
Operation
continued
z:
Operation
not
continued
(Note 1)
Pr. 156
Setting
Fast-
Response
Current
Limit
{: Activated
z: Not
activated
Stall Prevention
Operation
Selection
{: Activated
z: Not activated
OL Signal
Output
{:
Operation
continued
z:
Operation
not
continued
(Note 1)
Acceleration
Constant
speed
Deceleration
Acceleration
Constant
speed
Deceleration
0
{ {{{ {
16
{{{{
z
1 z
{{{ { 17 z {{{ z
2
{
z
{{ {
18
{
z
{{
z
3 zz
{{ {
19 zz
{{
z
4
{{z {{ 20 {{z { z
5 z
{
z
{{
21 z
{
z
{
z
6
{
zz
{{
22
{
zz
{
z
7 zzz
{{ 23 zzz{ z
8
{{{
z
{
24
{{{
zz
9 z
{{
z
{
25 z
{{
zz
10
{ z { z { 26 { z { zz
11 zz
{
z
{
27 zz
{
zz
12
{{
zz
{
28
{{
zz z
13 z
{ zz { 29 z { zz z
14
{
zzz
{
30
{
zzz z
15 zzzz— (Note2) 31 z zzz— (Note2)
100
Driving
{{{{{
Regenerative
z zzz— (Note2)
Pr. 22-A
Pr. 22-B
Pr. 23-100
100
Pr. 66 (Hz) × Pr. 22 (%)
output frequency (Hz)
Pr. 66 (Hz) × Pr. 22 (%)
400Hz