Instruction manual

170
PARAMETERS
<Examples of use>
(1) Registration of parameter to user group (when registering Pr. 3 to
user group 1)
(2) Deletion of parameter from the user group (when Pr. 5 is deleted from
user group 1)
(3) Set the required value in Pr. 160 to make the user group or groups
valid or invalid.
Pr. 160 Setting Description
0 Accessible to all parameters.
1
Accessible to only the parameters
registered to user group 1.
10
Accessible to only the parameters
registered to user group 2.
11
Accessible to only the parameters
registered to user groups 1 and 2.
Note:1. The Pr. 77, Pr. 160 and Pr. 991 values may always be read independently of
the user group setting.
2. The Pr. 173 or Pr. 174 value read indicates the number of parameters
registered to group 1, and the Pr. 175 or Pr. 176 value read indicates the
number of parameters registered to group 2.
3. If "0" is set in the second digit of two-digit Pr. 160, it is not displayed.
However, "0" is displayed when it is set in the first digit only.
4. When "9999" is set in Pr. 174 or Pr. 176, the parameters registered to the
corresponding user group are batch-deleted.
Flickering
Pr. 173 reading
The number of
parameters set and
registered by the
user appears.
Pr. 3 is registered
to user group 1.
Press the /
key to select the
parameter number to
be registered.
Press the /
key to shift to the next
parameter to be
registered.
Press the key to
register the parameter.
SET SET
1.5s




SET
Pr. 174 reading
The number of
parameters set and
registered by the
user appears.
Pr. 5 is deleted
from user group 1.
Flickering
SET SET
1.5s




Press the /
key to select the
parameter number to
be deleted.
Press the /
key to shift to the next
parameter to be
deleted.
Press the key to
delete the parameter.
SET