Specifications

Standard Specifications
Common Specifications
Output signals
Operation specifications
Control method selection Soft-PWM control or high carrier frequency PWM control; select V/F control or general-purpose flux vector control.
Output frequency range 0.2 to 400Hz (variable starting frequency 0 to 60Hz)
Analog input
(Note 4)
Between terminals 2 and 5 1/500 of the maximum set frequency (for the 5V DC input), 1/1000 of maximum set frequency (for the 10V DC
input at 4 to 20mA DC), or 1/256 of maximum set frequency (using control panel knob).
Digital input
(Note 4)
When set digitally on control panel 0.01Hz (less than 100Hz) or 0.1Hz (100Hz and up).
Analog input
(Note 4)
±0.5% of maximum output frequency 25°C (53°F) ±10°C (±21.2°F).
Digital input Within 0.01% of set output frequency.
Voltage/frequency characteristics Any base frequency setting possible between 0 and 400Hz; constant torque or variable torque pattern selection possible.
Starting torque Minimum 150% at 1Hz or minimum 200% at 3Hz: General purpose flux vector control when set for slip compensation.
Torque boost Manual torque boost can be set between 030%
Acceleration time setting 0.01 to 3,600 seconds
Deceleration time setting 0.01 to 3,600 seconds
Acceleration/deceleration pattern Linear, S-curve A, or S-curve B modes.
Regenerative
(Note 1)
0.1 and 0.2K: 150% minimum; 0.4 and 0.75K: 100% minimum; 1.5K: 50% minimum; 2.2K, 3.7K, 5.5K and 7.5K: 20% minimum.
Braking torque
DC braking Variable operation frequency (0 to 120Hz), operation time (0 to 10 seconds), operation voltage (0 to 30%).
Current stall prevention operation level Operation current level setting possible (0 to 200% variable), enable/disable selection.
Voltage stall prevention operation level Operation level is fixed, enable/disable selection.
High-response current restriction level Operation level is fixed, enable/disable selection.
Analog input
(Note 4)
0 to 5V DC, 0 to 10V DC, 4 to 20mA DC, built-in analog knob.
Digital input Input from control panel. (CC-Link Series: Input using CC-Link communications or parameter unit.)
Starting signal
(Note 5)
Individual selection of forward or reverse run; starting signal self-hold input (3-wire input) selective.
Alarm reset
(Note 6)
Used to reset alarm output provided when protective function is activated.
Multi-speed selection
(Note 6)
Up to 15 set speeds (each speed can be set between 0 and 400Hz; speed can be changed via control panel or during operation).
2nd function selection
(Note 6)
Selects 2nd function (acceleration time, deceleration time, torque boost, base frequency, electronic overcurrent protection).
Output stop
(Note 6)
Instant shut-off of inverter output (frequency and voltage).
Current input selection
(Note 4)
Select input of frequency setting signal 4 to 20mA DC (terminal No.4).
Select self-hold at start
(Note 4)
Select self-hold of start signal.
External thermal input
(Note 6)
Thermal contact input for when stopping inverter with an externally mounted thermal relay.
Switching between operation modes
(Note 4)
PU and external operation Enables external switching between PU operation and external operation.
Switch between V/F and general-purpose
flux vector control
(Note 6)
Enables external switching between V/F control and general-purpose flux vector control.
Maximum and minimum frequency settings, frequency jump operation, external thermal input selection, instantaneous power failure
Operation functions restart operation, forward run/reverse run prevention, slip compensation, operation mode selection, off-line auto tuning function, PID
control
(Note 4)
, and computer link operation (RS-485), CC-Link operation
(Note 8)
.
Two types of open collector output can be selected from: inverter running, frequency reached, frequency detection, overload warning,
Operation status zero current detection, output current detection, maximum PID
(Note 4)
, minimum PID
(Note 4)
, PID forward run, PID reverse run
(Note 4)
,
operation ready, minor failure, and error. One type can be selected for the contact output (AC 230V 0.3A, DC 30V 0.3A).
For meter
(Note 4)
One type can be selected from: output frequency, motor current, or output voltage. Pulse train output (1440 pulse/second full scale).
Operation status Output voltage, output current, set frequency, and running.
Error details Details of errors are displayed when the protective function activates. Details of up to four errors are saved.
Displayed on LED Power on (POWER), Error (ALARM) (CC-Link Series: Power (POWER), Error (ALARM), Operational state (L.RUN, SD, RD, L.ERR))
Overcurrent shut-off (during acceleration, deceleration, and constant speed), regenerative overvoltage shut-off, undervoltage
(Note 3)
,
instantaneous power failure
(Note 3)
, overload shut-off (electronic thermal relay), output short, stall prevention, brake resistor overheating,
fin overheating, fan breakdown
(Note 5)
, parameter error, PU disconnected, ground fault protection.
Ambient temperature
-
10°C (
-
21.2°F) to +50°C (+106°F) (no freezing;
-
10 to +40°C for IP40 model).
Ambient humidity 90% RH or less (no condensation)
Storage temperature
(Note 2)
-
20˚C (+42.4°F) to +65˚C (+137.8°F)
Atmosphere Indoors (no corrosive gases, flammable gases, oil mist or dust)
Altitude and vibration Maximum 1000m (3280.8 ft) above sea level, maximum 5.9 m/s
2
{0.6G} (Conform to JIS C 0911.)
Frequency
control
resolution
Environment Display
Frequency
precision
Input signals
Frequency
setting
signal
(Note 5)
Select using
Pr.180 to Pr.183.
Displayed on
control panel
Protective and warning functions
9
Notes: 1. The indicated control torque size is the short-term average torque (which changes with motor loss) when decelerated at maximum rate from 60Hz when the motor
is operated alone. It is not continuous regenerative torque. Deceleration from frequencies in excess of the base frequency will have lower average deceleration
torque values. The inverters have no built-in brake resistors, so when the regenerative energy is high, use the optional brake resistor. A BU model brake unit may
also be used (except with 0.1K and 0.2K models). The control torque when a brake resistor is used is shown on page 41; the same for when a brake unit is used
is shown on page 36.
2. Temperature to which units can be exposed for a short time, such as during transportation.
3. When an insufficient voltage or instantaneous power failure occurs, error display and output do not work, but the inverter is protected. Depending on the operating
status (e.g., the size of the load),. Overcurrent protection, regenerative overvoltage protection etc. may engage upon restoration of power.
4. This function is not available for the CC-Link Series.
5. For the CC-Link series, can be set by means of CC-Link communications or the optional parameter unit.
6. For the CC-Link series, can be set by means of CC-Link communications or one of the input terminals.
7. For the CC-Link series, display is possible when the optional parameter unit is in use.
8. This form is not available with the frequency setting volume type.