Instruction manual

59
I/O signal list
4
CC-LINK COMMUNICATION FUNCTION
4.5.5 I/O signals when CC-Link Ver. 2 octuple setting is selected (Pr. 544 =
"
18
"
)
(1) Remote I/O (32 points)
Same as when Pr. 544 = "0" (Refer to page 56)
(2) Remote register
("n" indicates a value determined according to the station number setting.)
∗1 When Pr. 128 = "50, 51, 60, 61", they are valid.
∗2 When Pr. 37 is not equal to "0", this will be machine speed display (1 increments).
Address
Description
Refer
to
Page
Address
Description
Refer
to
Page
Upper 8 Bits Lower 8 Bits Upper 8 Bits Lower 8 Bits
RWwn Monitor code 2 Monitor code 1 62 RWrn First monitor value 63
RWwn+1 Set frequency (0.01Hz increments)
*2 62 RWrn+1 Second monitor value 63
RWwn+2
Link parameter
extended setting
Instruction code 62 RWrn+2 Reply code 2 Reply code 1 63
RWwn+3 Write data 62 RWrn+3 Read data 63
RWwn+4 Monitor code 3 62 RWrn+4 Third monitor value 63
RWwn+5 Monitor code 4 62 RWrn+5 Fourth monitor value 63
RWwn+6 Monitor code 5 62 RWrn+6 Fifth monitor value 63
RWwn+7 Monitor code 6 62 RWrn+7 Sixth monitor value 63
RWwn+8 Faults history No. H00 62 RWrn+8 Faults history No. Fault data 63
RWwn+9 PID set point (0.01% increments)
*1 62 RWrn+9 Fault record (output frequency) 63
RWwn+A
PID measured value (0.01% increments)
*1 62 RWrn+A Fault record (output current) 63
RWwn+B PID deviation (0.01% increments)
*1 62 RWrn+B Fault record (output voltage) 63
RWwn+C
H00 (Free)
RWrn+C Fault record (energization time) 63
RWwn+D RWrn+D
H00 (Free) RWwn+E RWrn+E
RWwn+F RWrn+F
RWwn+10
Link parameter
extended setting
Instruction code 62 RWrn+10 Reply code 63
RWwn+11 Write data 62 RWrn+11 Read data 63
RWwn+12
Link parameter
extended setting
Instruction code 62 RWrn+12 Reply code 63
RWwn+13 Write data 62 RWrn+13 Read data 63
RWwn+14
Link parameter
extended setting
Instruction code 62 RWrn+14 Reply code 63
RWwn+15 Write data 62 RWrn+15 Read data 63
RWwn+16
Link parameter
extended setting
Instruction code 62 RWrn+16 Reply code 63
RWwn+17 Write data 62 RWrn+17 Read data 63
RWwn+18
Link parameter
extended setting
Instruction code 62 RWrn+18 Reply code 63
RWwn+19 Write data 62 RWrn+19 Read data 63
RWwn+1A
H00 (Free)
RWrn+1A
H00 (Free)
RWwn+1B RWrn+1B
RWwn+1C RWrn+1C
RWwn+1D RWrn+1D
RWwn+1E RWrn+1E
RWwn+1F RWrn+1F
Parameters referred to
Pr. 37 Speed display Refer to page 175
Pr. 128 PID action selection Refer to page 203
Pr. 544 CC-Link extended setting Refer to page 105