INVERTER INVERTER INVERTER Option unit FR-PU07(-01) INSTRUCTION MANUAL IB(NA)-0600421ENG-B(1202) MEE Printed in Japan Specifications subject to change without notice.
Thank you for choosing the Mitsubishi inverter option unit. This instruction manual gives handling information and precautions for use of this equipment. Incorrect handling might cause an unexpected fault. Before using the equipment, please read this manual carefully to use the equipment to its optimum. Please forward this manual to the end user.
2. Additional Instructions (3) Usage To prevent injury, damage or product failure, please note the following points. (1) Transportation and mounting CAUTION Environment • Do not install and operate the parameter unit (FR-PU07) if it is damaged or has parts missing. • Do not stand or rest heavy objects on this equipment. • Check the inverter mounting orientation is correct. • The parameter unit (FR-PU07) is a precision device. Do not drop it or subject it to impact.
— CONTENTS — 1 INTRODUCTION 1 PRE-OPERATION INSTRUCTIONS 2 1.1 Supporting inverter models ..............................................................................................................2 1.2 Unpacking and Product Confirmation .............................................................................................3 1.2.1 1.2.2 1.3 Installation and Removal of FR-PU07 ..............................................................................................6 1.3.1 1.3.2 1.
2.1.3 2.1.4 2.1.5 2.2 Frequency Setting............................................................................................................................20 2.2.1 2.2.2 2.2.3 2.3 II Calibration of the FM terminal ...................................................................................................................... 32 Calibration of the AM terminal ......................................................................................................................
3.1 Overview of Function Menu ............................................................................................................43 3.1.1 3.1.2 3.2 Operation Procedures for Functions .............................................................................................49 3.2.1 3.2.2 3.2.3 3.2.4 3.2.5 3.2.6 3.2.7 3.2.8 3.2.9 3.2.10 3.2.11 3.2.12 3.3 Monitor function .........................................................................................................................
4.2 How to Operate PU Operation ........................................................................................................74 4.2.1 4.2.2 4.3 Combined Operation (Operation Using External Input Signals and PU)....................................76 4.3.1 4.3.2 4.3.3 5 Normal operation .......................................................................................................................................... 74 PU Jog operation..................................................
INTRODUCTION This product is a unit for setting inverter functions (parameters) and has the following features. · An operation panel can be removed and a parameter unit can be connected. · Setting such as direct input method with a numeric keypad, operation status indication, and help function are usable. · Eight languages can be displayed. · Parameter setting values of maximum of three inverters can be stored.
1 1.1 PRE-OPERATION INSTRUCTIONS Supporting inverter models (1) FR-PU07(-01) supporting models Model A700 series F700 series E700 series D700 series 500 series *1 *2 *3 FR-PU07 FR-PU07-01 { { { *2 { *2 { *1, *2 × { *3 × × × {:supported × :not supported Some parameter names displayed are different from those of the FR-PU07. The FR-PU07 cannot be directly connected to the inverter. To connect to the inverter, the dedicated cable is required. The following functions are available when using FR-PU07-01.
Unpacking and Product Confirmation 1.2 Unpacking and Product Confirmation Take the parameter unit out of the package, check the unit name, and confirm that the product is as you ordered and intact. 1.2.1 Appearance and parts identification Unpack the parameter unit, check the name plate on the back, and make sure that the product has not been damaged before using. Front Rear POWER lamp Connector for inverter directly Lit when the power turns ON. READ:List 60.
Unpacking and Product Confirmation 1.2.2 Explanation of keys Key Description Used to select the parameter setting mode. Press to select the parameter setting mode. Used to display the first priority screen. Used to display the output frequency when making an initial setting. Operation cancel key. Used to display the function menu. A variety of functions can be used on the function menu. Used to shift to the next item in the setting or monitoring mode.
Unpacking and Product Confirmation Key Description Forward rotation command key. Reverse rotation command key. · Stop command key. · Used to reset the inverter when a fault occurs. · Used to write a set value in the setting mode. · Used as a clear key in the all parameter clear or alarm history clear mode. · Used as a decimal point when entering numerical value. · Used as a parameter number read key in the setting mode.
Installation and Removal of FR-PU07 1.3 Installation and Removal of FR-PU07 To ensure safety, install or remove FR-PU07 after switching the power of the inverter OFF. FR-PU07 cannot be directly installed to the FR-E700, D700 inverter. 1.3.1 Direct installation to the inverter (A700/F700 series) (1) Remove the operation panel (FR-DU07). (2) Insert the parameter unit straight and fit it securely. (3) Tighten the two screws on the parameter unit to fix the unit to the inverter.
Installation and Removal of FR-PU07 1.3.2 Removal from the inverter (A700/F700 series) Loosen the fixed screws, hold down the right and left hooks of the FR-PU07, and then pull the parameter unit toward you. Press the hooks.
Installation and Removal of FR-PU07 1.3.3 Installation using the connection cable (FR-CB2) •For the FR-A700/FR-F700 (1) Remove the operation panel (FR-DU07). (2) Securely insert one end of connection cable into the PU connector of the inverter and the other end into the connection connector of FR-PU07 along the guides until the stoppers are fixed. FR-PU07 Stopper STF FWD PU Connection cable CAUTION Do not connect the connection cable when the front cover is removed.
Installation and Removal of FR-PU07 •For FR-E700 (1) Open the PU connector cover. (2) Securely insert one end of connection cable into the PU connector of the inverter and the other end into the connection connector of FR-PU07 along the guides until the stoppers are fixed. Stopper FR-PU07 PU connector STF FWD PU Connection cable 1 Stopper CAUTION Do not connect the connection cable when the front cover is removed.
Installation and Removal of FR-PU07 •For FR-D700 (1) Remove the inverter front cover. (For the removal of the front cover, refer to the inverter manual.) (2) Securely insert one end of connection cable into the PU connector of the inverter and the other end into the connection connector of FR-PU07 along the guides until the stoppers are fixed. PU connector FR-PU07 Stopper STF FWD PU Stopper Connection cable CAUTION Do not connect the connection cable when the front cover is removed.
Parameters to be Checked First 1.4 Parameters to be Checked First Change the following parameter settings as required. For the changing procedures, refer to page 23. 1.4.1 PU display language selection (Pr. 145) By setting the Pr. 145 PU display language selection value, you can select the language displayed on the parameter unit. Pr. 145 Setting 0 1 (initial value) 2 3 4 5 6 7 1.4.2 Display Language Japanese English German French Spanish Italian Swedish Finnish 1 PU buzzer control (Pr.
Parameters to be Checked First 1.4.3 PU contrast adjustment (Pr. 991) By setting the Pr. 991 PU contrast adjustment value, you can adjust the contrast for the display panel of the parameter unit. Pr.
2 FUNCTIONS 2.1 Monitoring Function 2.1.1 Display overview (1) Main monitor READ:List OL Hz 120.00 STF (2) Rotation direction indication (1) Main monitor Shows the output frequency, output current, output voltage, alarm history and other monitor data.
Monitoring Function READ:List OL Hz 120.00 STF FWD PU (6) Warning indication (5) Unit indication (4) Operating mode indication (4) Operation mode indication Displays the status of the operation mode. EXT : External operation mode PU : PU operation mode EXTj : External Jog mode PUj : PU Jog mode NET : Network operation mode PU+E : External/PU combined operation mode (5) Unit indication Shows the unit of the main monitor. 14 (6) Warning indication Displays an inverter warning.
Monitoring Function 2.1.2 Using "S HIFT" to change the main monitor When "0" (initial value) is set in the Pr. 52 DU/PU main display data selection, simply pressing different monitor screens in sequence. calls 6 Switch power ON or press When output frequency is the first priority monitor (Initial setting) When output current is the first priority monitor READ:List READ:List 0.00 Hz --- STOP EXT --- STOP EXT Output current monitor 0.00Hz 0.00A 0.
Monitoring Function 2.1.3 Setting the power-ON monitor (the first priority monitor) Set the monitor which appears first when power is switched ON or • When you press during any monitor screen other than ALARM HISTORY being displayed, that screen is set as the power-ON screen and will be displayed first. 16 is pressed.
Monitoring Function 2.1.4 Using "READ" to change the main monitor Press to display the monitoring list while the main monitor is displayed. Select a monitor from the monitoring list to change the main monitor. Example: Select the output current peak value monitor. *1 The selected monitor is not set as the first priority 1 Press . 0.00 A The parameter unit is in the monitoring mode. 2 Press . The monitoring list appears.
Monitoring Function 2.1.5 Using the parameter to change the monitor (Pr. 52) To change the third monitor (output voltage monitor), set Pr. 52 DU/PU main display data selection. (Note that setting "17" (load meter) *2, "18" (Motor excitation current) *1 *2, and "24" (Motor load ratio) change the output current monitor. "Output voltage monitor" monitor displays from the first priority monitor using *1 *2 Cannot be monitored for the FR-F700 series. Cannot be monitored for the FR-E700, D700 series.
Monitoring Function Factory setting * The monitor displayed at powering ON is the first priority monitor. Refer to page 16 for the setting method of the first priority monitor. First priority monitor Second monitor Third monitor READ:List READ:List READ:List 0.00 A 0.00 Hz 0.
Frequency Setting 2.2 Frequency Setting The frequency in PU operation mode and External/PU combined operation mode (Pr. 79 = "3") can be set. REMARKS When changing the operation mode from External operation mode to PU operation mode, operation mode can not be changed if the external starting signal (STF or STR) is ON. 2.2.1 Direct setting Directly enter a frequency setting using to . • Operation procedure (Changing from 0Hz setting to 60Hz setting) 1 Press . The frequency setting screen appears.
Frequency Setting 2.2.2 Step setting Change frequency continuously using / . You can change the frequency only while you press / . Since the frequency changes slowly at first, this setting can be used for fine adjustment. 1 Press . The frequency setting screen appears. 2 Press / You can set any value between the maximum frequency (Pr. 1 ) and minimum frequency (Pr. 2 ). 3 Press Change of frequency can be made during operation by 0~400Hz the step setting.
Frequency Setting 2.2.3 Precautions for frequency setting 1) Pr. 79 Operation mode selection must have been set to switch to the PU operation. (Refer to the inverter instruction manual for details of Pr. 79 .) 2) In the monitor mode, you cannot make the direct setting (Refer to page 20) to set the running frequency. Perform the step setting (Refer to page 21) and press , or press to display the frequency setting screen before frequency setting. Monitor mode READ:List 30.
Setting and Changing the Parameter Values 2.3 Setting and Changing the Parameter Values Using the FR-PU07 allows you to read the parameter of inverter or change the set value easily. Refer to the inverter instruction manual for details of the parameters. 2.3.1 Specifying the parameter number to change the set value Example: When changing 5s to 180s at the Pr. 8 Deceleration time setting 1 Press . (You need not press when the parameter unit is already in the PU operation mode.) 2 Press .
Setting and Changing the Parameter Values 2.3.2 Selecting the parameter from functional list to change the set value Example: When changing 5s to 180s at the Pr. 8 Deceleration time setting 1 Press . The frequency setting screen appears, and operation mode changes to PU operation mode. 2 Press . The parameter unit is in the parameter setting mode. 3 4 SETTING MODE 0~9:Ser Pr.NO. Appl.Grp Pr.List User List Param Copy Press 1 2 3 4 Basic Func F Command Acc.
Setting and Changing the Parameter Values 10 (1) Direct setting Press .* Enter the desired value. 8 Dec.T1 5.0S 180S 0~3600 Or (2)Step setting Press . Display "180" using 11 Press . The set value is changed. . 8 Dec.T1 180.0S Completed 12 * Press to display the next parameter. If is pressed when an incorrect setting value is input, the display returns to the list display "8".
Setting and Changing the Parameter Values 2.3.3 Selecting the parameter from parameter list to change the set value Example: When changing 5s to 180s at the Pr. 8 Deceleration time setting 1 Press The frequency setting screen appears, and operation mode changes to PU operation mode. . The parameter unit is in the parameter setting mode. 3 Change the screen using . 4 Select a parameter list. Using , point the cursor to "Pr.List". 5 Press . Select the parameter list.
Setting and Changing the Parameter Values 2.3.4 Selecting the parameter from User List to change the set value If a parameter is registered to User List, the parameter can be read from User List and changed. (For registering the user group, refer to page 29 .) Example: When changing 5s to 180s at the Pr. 8 6 Select the parameter. Deceleration time setting When moving the cursor 8 Dec.T1 1 Press using . The frequency setting screen appears, and operation mode changes to PU operation mode. 2 Press .
Setting and Changing the Parameter Values 2.3.5 Precautions for setting write · Perform parameter setting change during an inverter stop basically in the PU operation mode or combined operation mode. The parameter setting can not be changed in the External operation mode or during inverter operation. (Read is performed independently of the operation mode.) Note that some parameters can be written even in the External operation mode or during operation. Therefore, refer to the inverter manual. · As Pr.
User Group Function 2.4 User Group Function · User group function is a function to display only parameters necessary for setting. · Among all parameters, maximum 16 parameters can be registered to the user group. When "1" is set in Pr. 160, only parameters registered in the user group can be accessed for reading and writing. (The parameters not registered to the user group cannot be read.) REMARKS FR-D700 does not have the user group function.
User Group Function 2.4.1 Registering the parameters to user group 1 Press . The parameter unit is in the parameter setting mode. SETTING MODE 0~9:Ser Pr.NO. Select Oper 2 Read the parameters. Enter the parameter number to be registered to the user group with the number keys and press to read the parameter setting. 8 Dec.T1 5.0S 0~3600 3 Set the parameters. When changing the set value, enter a new value with the number keys and press to write. When not changing the 8 Dec.T1 5.
User Group Function 2.4.2 Deleting the parameters from user group 1 Press . The parameter unit is in the parameter setting mode. SETTING MODE 0~9:Ser Pr.NO. Select Oper 2 Select "User List". Using / , point the cursor to "3 User List" and press . 1 2 3 4 Appl.Grp Pr.List User List Param Copy Using / , point the cursor to the parameter to be deleted and press 1 2 3 7 Max.F1 Min.F1 VFbaseF1 Acc.T1 4 Delete. pressing deleted. , the parameter is 2.4.3 1 2 7 8 Max.F1 Min.F1 Acc.T1 Dec.
Calibration of the Meter (Frequency Meter) 2.5 Calibration of the Meter (Frequency Meter) The functions vary with the inverter. (Refer to the inverter instruction manual for details of the parameters.) 2.5.1 Calibration of the FM terminal 3 Parameter Pr. 900 FM terminal calibration Pr. 54 FM terminal function selection Pr. 55 Frequency monitoring reference press This section provides the way to calibrate the fullscale of meter connected to terminal FM using the parameter unit.
Calibration of the Meter (Frequency Meter) 7 Press . Calibration is complete. 8 Press to return to the main monitor screen. 900 FM Tune Completed READ:List 60.00 Hz STF FWD PU 2.5.2 Calibration of the AM terminal Parameter Pr. 901 AM terminal calibration Pr. 158 AM terminal function selection Pr. 55 Frequency monitoring reference Pr. 56 Current monitoring reference This section provides a way to calibrate the meter connected to terminal AM using the parameter unit.
Calibration of the Meter (Frequency Meter) 4 Enter and press . 60Hz is set. 5 Press . Forward rotation is performed at 60Hz. You need not connect the motor. 6 Using / (2) When calibrating output current 901 AM Tune Run Inverter 60Hz PU 901 AM Tune MntrF 60.00Hz For the output current or another item, which does not easily point 100% value during operation, adjust the reference voltage output, then select the item to be displayed. 1 2 Press predetermined position. The meter pointer moves.
Calibration of the Meter (Frequency Meter) 6 Enter press . The present Pr. 901 setting appears. 7 Enter The setting of maximum running frequency is complete. Press Using 901 AM Tune Run Inverter 60Hz PU / 901 AM Tune MntrF 1000 PU . SETTING MODE 0~9:Ser Pr.NO. The parameter unit is in the parameter setting mode. 11 Enter press . Forward rotation is performed at 60Hz. You need not connect the motor to make adjustment. 9 901 AM Tune Run Inverter 0.00Hz PU and press .
Adjustment of the Frequency Setting Signals "Bias" and "Gain" 2.6 Adjustment of the Frequency Setting Signals "Bias" and "Gain" The functions vary with the inverter model. (Refer to the inverter instruction manual for details of the functions.) 2.6.1 Adjustment procedure There are three ways to adjust the bias and gain of the frequency setting voltage (current).
Adjustment of the Frequency Setting Signals "Bias" and "Gain" (1) Adjust only the bias and gain frequencies and not adjust the voltage • Setting of the frequency setting voltage bias 1 Press . The frequency setting screen appears, and operation mode changes to PU operation mode. 2 Press . The parameter unit is in the parameter setting mode. 3 Enter press Enter Press . The bias frequency is set at 10Hz. f 0~400Hz 0 SETTING MODE 0~9:Ser Pr.NO. Select Oper 902 Ext2bias 10.
Adjustment of the Frequency Setting Signals "Bias" and "Gain" • Setting of the frequency setting voltage gain 6 Press . The present setting appears. 7 Enter . Voltage need not be applied across terminals 2-5. 8 Press 903 Ext2gain 60.00Hz Set Ext 903 Ext2gain 50Hz Set . The bias frequency is set at 50Hz. At this time, set the gain on the assumption that the 5V (10V) in the inverter is the set voltage. 903 Ext2gain 50.
Adjustment of the Frequency Setting Signals "Bias" and "Gain" (2) Adjust any point by application of voltage to across terminals 2-5 • Setting of the frequency setting voltage bias 1 Press . The frequency setting screen appears, and operation mode changes to PU operation mode. 2 Press . The parameter unit is in the parameter setting mode. 3 4 Enter . Press twice. The present Pr. 902 setting appears. When the set voltage is changed, the % value also changes.
Adjustment of the Frequency Setting Signals "Bias" and "Gain" • Setting of the frequency setting voltage gain 9 Press , then . The present Pr. 903 setting appears. When the set voltage is changed, the % value also changes. The value selected in Pr. 73 (5V in this example) is 100%. 10 11 Enter Press The cursor ( set voltage. 12 40 . . ) moves to the Apply a 5V voltage. In this example, 5V is applied to set 50Hz for 5V input. 903 Ext2gain 60.00Hz 97.1% Ext 80.0% 13 903 Ext2gain 50.00Hz 97.
Adjustment of the Frequency Setting Signals "Bias" and "Gain" (3) Adjust any point without application of voltage to across terminals 2-5 • Setting of the frequency setting voltage bias 1 Press . The frequency setting screen appears, and operation mode changes to PU operation mode. 2 Press . The parameter unit is in the parameter setting mode. 3 4 5 . Set the bias frequency at 10Hz. 6 Freq Set SET 0.00Hz Enter Press . The cursor ( ) moves to the set voltage.
Adjustment of the Frequency Setting Signals "Bias" and "Gain" • Setting of the frequency setting voltage gain 9 Press , then . The present Pr. 903 setting value appears. When the set voltage is changed, the % value also changes. The value selected in Pr. 73 (5V in this example) is 100%. 10 Enter . Set the gain frequency at 50Hz. 11 1) 2) f 50Hz 10Hz 0 (0%) 5V (100%) 903 Ext2gain 50.00Hz 100.0% Completed V The adjustment of the frequency setting voltage bias and gain is complete. 1 .
3 FUNCTION MENU 3.1 Overview of Function Menu Press in any operation mode to call the function menu, on which you can perform various functions. Hold down and press to shift one screen. Menu screen page 1 1 2 3 4 Press any of the 3.1.1 Menu screen page 2 MONITOR PU Oper Pr.list Pr.Clear 5 6 7 8 + , , Alarm Hist AlarmClear INV.Reset T/Shooting and Menu screen page 3 + 9 10 11 12 S/W Selectop Option FRCpy set keys to switch to the corresponding mode.
Overview of Function Menu Function Menu 5. Alarm Hist 6. AlarmClear 7. Inv.Reset Description This function displays history of past eight faults (alarms). This function clears all the fault (alarm) history. This function resets the inverter. 8. T/Shooting The inverter displays the cause of mismatch between inverter operation and control/ setting or the cause of an inverter fault. 9. S/W This function displays the software control number of the inverter. 10.
Overview of Function Menu 3.1.2 Function menu transition 1 MONITOR 2 PU Oper 3 4 5 6 7 8 9 10 11 12 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Frequency Current Voltage Alarm His F Command RPM Shaft Trq DC Link Br.
Overview of Function Menu 1 2 3 4 1 2 3 4 5 6 7 8 9 10 11 12 Setting Mode Pr.List Set Pr.List Def.Pr.List Select Oper 0 1 2 3 Pr.List Pr.Clear Alarm His AlarmClear Trq Bst1 Max.F1 Min.F1 VFbaseF1 SET Pr.LIST 15 JOG F 15.00 79 Oper 1 125 2Freq 50.00 DEF.Pr.LIST 0 Trq B 6.0 1 Max.F 120.00 2 Min.F 0.00 1 Clear Pr. 2 Clear All 1 2 3 4 OHT SER OV2 OV2 5 6 7 8 OV2 0V3 OV3 OV3 ALARM CLEAR Exec Cancel 46 SETTING MODE 0~9:Ser Pr.No. 1 2 3 4 Appl.Grp Pr.
Overview of Function Menu INV.RESET Exec Cancel [Estimated cause] 1 2 3 4 5 6 7 INV.Reset 8 T/Shooting 9 S/W 10 11 12 1 2 3 4 M.Not Run M.Spd Error M.A/Dec Err M.Curr.High M.NOT RUNNING NO I/P Power or Phase Loss INV.Output 0.00Hz 0.00A 0.0V Set 5.0S 0 60.00Hz Set 5.0S 60.00Hz 0 INV.Output 0.00Hz 0.00A 0.0V V/f Setting Error? See Pr.3,14, 19,47,113 Stll Pv.ON? Set Too Low? Load Too Big? Pr.22 Error? Low Impedance Motor? Reduce TrqBst Pr.
Overview of Function Menu Settings of Pr. 178 to Pr. 196 are displayed.
Operation Procedures for Functions 3.2 Operation Procedures for Functions 3.2.1 Monitor function The monitoring list appears and you can change from one monitor screen to another and set the first priority screen. 1 Press 5 . The function menu is called. 2 Make sure that the cursor is located at "1 MONITOR". 1 2 3 4 MONITOR PU Oper Pr.List Pr.Clear If not, move the cursor with / 3 . The monitor screen selected by the cursor appears. Press to give the first priority to this monitor screen.
Operation Procedures for Functions 3.2.2 Selection of PU operation (direct input) You can select the PU operation mode to set PU operation frequency. 1 Press . The function menu is called. 2 Using , move the cursor to "2 PU Oper". 3 Press 1 2 3 4 MONITOR PU Oper Pr.List Pr.Clear 1 2 3 4 MONITOR PU Oper Pr.List Pr.Clear The menu on the right appears. is located at "1 PU: Directly". 5 Press 50 and press SET . The frequency setting is complete. 7 Press · Press time. . .
Operation Procedures for Functions 3.2.3 Selection of the PU Jog operation mode You can select the PU Jog operation mode to set PU jog frequency. 1 Press . The function menu is called. 2 Using , move the cursor to "2 PU Oper". 3 Press . The menu on the right appears. 4 Using , move the cursor to "2 JOG: Jogging". 5 Press 6 Enter the set frequency 1 2 3 4 1 2 3 4 MONITOR PU Oper Pr.List Pr.Clear MONITOR PU Oper Pr.List Pr.Clear 1 PU:Directly 2 JOG:Jogging to and press PU/JOG 5.
Operation Procedures for Functions 3.2.4 Parameters When selecting the parameter on the function menu, the parameter menu is displayed, and you can perform the following operations for the parameters. Display 1 Setting Mode 2 Pr. List 3 Set Pr. List 4 Def.Pr. List 52 Description Switches to the parameter setting mode to read and write the parameter setting. Displays the parameters list. You can select the parameter from the list to read and write the parameter setting.
Operation Procedures for Functions (1) "1 Setting Mode" 1 Press . The function menu is called. 2 Using , move the cursor to "3 Pr. List". 3 Press . The parameter menu appears. 4 Press 2 1 2 3 4 MONITOR PU Oper Pr.List Pr.Clear 1 2 3 4 MONITOR PU Oper Pr.List Pr.Clear 1 2 3 4 Setting Mode Pr.List Set Pr.List Def.Pr.List SETTING MODE 0~9:Ser Pr.NO. Select Oper (2) "2 Pr.List" 1 Call the parameter menu similarly to above steps 1 to 3. 1 2 3 4 Setting Mode Pr.List Set Pr.List Def.Pr.
Operation Procedures for Functions (3) Display of "3 Set Pr.List" 1 Call the parameter menu 2 similarly to steps 1 to 3 of page 53. 1 2 3 4 Setting Mode Pr.List Set Pr.List Def.Pr.List Using 1 2 3 4 Setting Mode Pr.List Set Pr.List Def.Pr.List / , move the cursor to "3 Set Pr. List". 3 Press . The change list appears. When the parameter has been changed from the initial value, the new value is displayed. 4 Press 1 Call the parameter menu 2 3 0~120 1 2 3 4 Setting Mode Pr.List Set Pr.
Operation Procedures for Functions 3.2.5 Parameter clear You can perform the "parameter clear" and "all parameter clear". Switch to the PU operation mode before performing any operation. • Clear Pr. .......................... Returns (initializes) the parameters to the factory settings with the exception of the some parameters (Pr. 75 and calibration values in Pr. 900 to Pr. 905 ). • Clear All........................... Initializes all parameters with the exception of Pr. 75.
Operation Procedures for Functions (2) All parameter clear 1 Call the parameter menu similarly to steps 1 to 3 of page 55. 1 Clear Pr. 2 Clear All 2 Select the "Clear All". / , move the cursor to "2 Clear All" and Using press the 3 4 . "Clear All" is selected, and the confirmation screen for clearing execution is displayed. Press Clear All Pr. Exec Cancel . The parameters are initialized. When canceling the initialization, press on the confirmation screen. 56 1 Clear Pr.
Operation Procedures for Functions 3.2.6 Alarm history Shows the history of past eight faults. 1 Press . The function menu is called. 2 Using / / 3 Press and press Press . . The running frequency at fault occurrence is displayed. 5 Press 5 6 7 8 Alarm His AlarmClear INV.Reset T/Shooting 1 2 3 4 OHT SER OV2 OV2 6 Press when displaying the operation mode for fault occurrence in steps 4 and 5 to display the operation data for the preceding fault occurrence. 2nd Prev.
Operation Procedures for Functions 3.2.7 Alarm clear Clears all the fault history. 1 Press . The function menu is called. 2 Using / / 3 Press and press . the confirmation screen for clearing is displayed. Press Alarm His AlarmClear INV.Reset T/Shooting ALARM CLEAR Exec Cancel . The fault history is cleared. When canceling the clear, press on the confirmation screen. 58 5 6 7 8 to shift one screen. "AlarmClear" is selected, and 4 MONITOR PU Oper Pr.List Pr.
Operation Procedures for Functions 3.2.8 Inverter reset Resets the inverter. 1 Press . The function menu is called. 2 Using / / 3 Press and press . the confirmation screen for reset is displayed. Press 5 6 7 8 Alarm His AlarmClear INV.Reset T/Shooting REMARKS · If the inverter's protective function is activated to bring the inverter to trip (output shutoff), execute the inverter reset only by pressing .
Operation Procedures for Functions 3.2.9 Troubleshooting If the inverter appears to operate improperly, perform the following operation to display the most likely cause of the fault. This operation may also be performed during inverter operation (PU operation, External operation) or during trip (protection activated). 1 Press . The function menu is called. 2 Using Hold down / Press and press Press . or to move the cursor to the desired item. 60 5 6 7 8 Alarm His AlarmClear INV.
Operation Procedures for Functions Troubleshooting guidance 1) M.NOT RUNNING (Motor does not run) M.NOT RUNNING ALARM Indicated The protective function is activated to bring the inverter to trip. Press to display the cause of the trip. M.NOT RUNNING Max. F1
Operation Procedures for Functions 2) M.SPEED ERROR 3) M.A/Dec Err (Speed does not match the running frequency (Actual acceleration/deceleration time is longer setting) than the Pr. 7/Pr. 8 setting) M. SPEED ERROR SetF
Operation Procedures for Functions 4) M.Curr.High (Inverter output current is larger than normal) INV.Output 60.00Hz 10A 182.4V First, the running frequency, output current and output voltage of the inverter are displayed. Press to display the estimated cause of large output current. Trq. Bst Setting Err? See Pr. 0, 46, 112 Since the torque boost setting may be inappropriate, check the following relevant parameters: Related parameters: Pr. 0, 46, 112 Low Impedance Motor? Reduce TrqBst Pr.
Operation Procedures for Functions 3.2.10 Terminal assignment (Selectop) The signals assigned to the control circuit terminals and their ON-OFF state are displayed. If the plug-in options FR-A7AX, FR-A7AY and FR-A7AR are mounted, the terminal state of the plug-in option can be also confirmed. 1 Press . The function menu is called. 2 Using / / 3 and press 9 10 11 12 S/W Selectop Option PRCpy set to shift one screen. Indicates Pr.178 to Pr.
Operation Procedures for Functions 3.2.11 Option Displays what options are fitted to the option connectors. 1 Press . The function menu is called. 2 Using / / 3 Press MONITOR PU Oper Pr.List Pr.Clear 9 10 11 12 S/W Selectop Option PRCpy set , move the cursor to "11 Option". Hold down 1 2 3 4 and press to shift one screen. . Numbers OP1 to OP3 correspond to numbers 1 to 3 of the option slot on the inverter side.
Operation Procedures for Functions 3.2.12 Multiple copies (1) Copying the parameter settings Parameter settings of an inverter can be read. The settings of maximum three inverters can be stored in the FR-PU07. You can also copy the stored parameter settings to another inverter of the same series. Confirm for setting · Is the PU operation mode selected? → If not, press · Is the inverter stopped? → If it is running, press to select the PU operation mode. to stop it. · Is the Pr.
Operation Procedures for Functions • Reading the parameter settings of the inverter and storing them to FR-PU07. 1 Connect the FR-PU07 to the copy source inverter. 2 Press . 1 MONITOR The function menu appears. 2 PU Oper 3 Pr.List 4 Pr.Clear 3 Select the "PRCpy set". Using / , move the cursor to "12 PRCpy set" and press 4 . 9 10 11 12 S/W Selectop Option PRCpy set Select the copy area. The copy area selection screen is displayed. Then, move the cursor to any one of 1 to 3 and press .
Operation Procedures for Functions • Writing the parameter setting stored in FR-PU07 to the inverter 1 6 Connect the FR-PU07 to the copy destination inverter. 2 Press . The function menu appears. 1 2 3 4 MONITOR PU Oper Pr.List Pr.Clear 9 10 11 12 S/W Selectop Option PRCpy set 7 press . press 1 Copy area 1 2 Copy area 2 3 Copy area 3 . 5 Select the "WRITE". Using / , point the cursor to "2 Write VFD" and press 68 . 8 012 Area 1 to VFD WRITE:Executing ESC:Cancel .
Operation Procedures for Functions (2) Verifying the parameters All the parameter settings stored in the FR-PU07 are verified with those which are stored in the inverter. REMARKS Verification cannot be performed between different inverter series. 1 Refer to page 67 and copy the parameter settings of the verify source inverter to the FR-PU07. 2 3 Press 6 Select the "Verifying". Using / , point the cursor to "3 Verifing" to press Connect the FR-PU07 to the inverter to be verified. .
Operation Procedures for Functions 9 10 If an error is detected during verification, the corresponding Pr. is shown. Note that only "Verify Err" will be displayed if an incorrect value has been entered directly (f setting) or set in either Pr. 173 or Pr. 174 . Press Param Copy Verify Err Pr. 2 Min.F1 . When verification is stopped with verification error, press to continue verification. 11 Verification is complete.
Other Precautions 3.3 3.3.1 Other Precautions Precautions for parameter unit operation Note the following items when operating the parameter unit to prevent setting from being disabled or incorrect values from being entered. • Precautions for the digit count and decimal point of input value The maximum number of input digits is six including a decimal point. If you enter a value in excess of 6 digits, the most significant digit is ignored. 12345.6 → 2345.
4 OPERATION 4.1 How to Select the Operation Mode 4.1.1 Switching from External operation mode [EXT] to PU operation mode [PU] Confirmation 4.1.2 Switching from PU operation mode [PU] to External operation mode [EXT] Confirmation Make sure that the external input signal (STF, STR) is OFF. READ:List 0.00 Hz Make sure that the external input signal (STF, STR) is OFF and that the operation command indication is "- - -". --- STOP EXT READ:List 0.00 Hz --- STOP PU Freq Set SET 0.
How to Select the Operation Mode 4.1.3 Switching to the External / PU combined operation mode Changing the Pr. 79 Operation mode selection setting to "3" or "4" switches to the External / PU combined operation mode. "PU+E" is displayed in the operation mode indication position. READ:List 0.00 Hz --- STOP PU+E The relationship between the running frequency and the start signal is as indicated in the following table. Description Running frequency setting Pr.
How to Operate PU Operation 4.2 How to Operate PU Operation 4.2.1 Normal operation During motor operation, the speed can be changed by simply executing Step 2. Step 1 Operation Procedure Switch power ON. Make sure that the monitor appears. Image 1. Power on Operation mode check Step 4 Operation Procedure Press . Image 4. Stop The motor is decelerated to a stop. Stop ON READ:List 0.00 Hz --- STOP PU 2 Set the running frequency. 2.
How to Operate PU Operation 4.2.2 PU Jog operation Step Hold down or to perform operation, and release it to stop. Jog operation cannot be performed in the following cases: · During motor operation · The Pr. 15 Jog frequency is less than the Pr. 13 Starting frequency. Example: To operate at the PU Jog running frequency of 8Hz Step 1 2 Operation Procedure Switch to the PU operation mode. If the operation mode indication is not [PU], refer to page 72 and switch to the PU operation mode.
Combined Operation (Operation Using External Input Signals and PU) 4.3 Combined Operation (Operation Using External Input Signals and PU) 4.3.1 Entering the start signal from outside and setting the running frequency from the PU (Pr. 79 = 3) The external frequency setting signals and and Step 4 of the parameter unit are not accepted. The operation command indication changes to "STF" or "STR" and the operation status indication changes to the output (FWD or REV) indication.
Combined Operation (Operation Using External Input Signals and PU) 4.3.2 Step 1 Entering the running frequency from outside and making start and stop from the PU (Pr. 79 = 4) Operation Procedure Switch the power ON. Step Image 4 1. Power on ON 2 Set "4" in Pr. 79 Operation mode selection. Enter the external frequency command. Select the multi-speed signal or turn the frequency setting potentiometer. Press or parameter unit.
Combined Operation (Operation Using External Input Signals and PU) 4.3.3 Step 1 Entering the start signal and multi-speed signal from outside and setting multiple speeds from the parameter unit Operation Procedure Switch the power ON. Step Image 4 1. Power on ON 2 Select the multi-speed signal required for operation. When high speed has been selected (RH signal ON), changing the Pr. 4 Multi-speed setting (high speed) value varies the speed. 2.
5 5.1 CHECK FIRST WHEN YOU HAVE A TROUBLE Troubleshooting If a fault occurs and the inverter fails to operate properly, locate the cause of the fault and take proper corrective action by referring to the troubleshooting below. If the corresponding information is not found in the table, the inverter has problem, or the component parts are damaged, contact your sales representative. Status Possible causes Connection fault of the parameter unit The LCD or backlight of the The setting of Pr.
6 SPECIFICATIONS 6.1 Standard Specifications Item Surrounding air temperature Ambient humidity Storage temperature Ambience Altitude, vibration Power supply Connection Display Data retention Number of write times Mass *1 Specifications -10°C to +50°C (non-freezing) *1 90%RH or less (non-condensing) -20°C to +65°C *2 Indoors (free from corrosive gas, flammable gas, oil mist, dust and dirt) Maximum 1000m above sea level for standard operation. 5.
Outline Drawing and Panel Cutting Drawing 6.2 Outline Drawing and Panel Cutting Drawing 6.2.1 FR-PU07 outline dimension drawings (14.2) 25.05 (11.45) 2.5 83 40 40 *1 Mounting hole 51 50 *1 4-R1 *1 57.8 67 56.8 135 *1 26.5 80.3 *1 *2 26.5 4- 4 hole (Valid screw depth 5.0) M3 screw *2 (Unit : mm) When installing the FR-PU07 on the enclosure, etc.
APPENDIX Appendix 1 Disposing of the equipment in the EU countries • The symbol shown below, which is printed on the product for EU countries, means that electric and electronic equipment, at their end-of-life, should be disposed of separately from your household waste. • Please, dispose of this equipment at your local community waste collection/recycling centre if it is to be disposed of in EU countries.
MEMO 83
REVISIONS *The manual number is given on the bottom left of the back cover. Print Date May 2010 Feb.