Specifications

Options
84
Radio noise filter (FR-BIF, FR-BIF-H)
This filter effectively controls noise emitted from the power supply side of the servo amplifier or converter unit, and is especially
effective for radio frequency bands 10MHz or lower. Available only for input.
FR-BIF
FR-BIF-H
Model
MR-J2S-22KMor smaller, MR-J2S-30KM or 37KM
MR-J2S-60M4 to MR-J2S-55KM4
External dimensions
MC
FR-BIF
or
FR-BIF-H
L1
Servo amplifier
L2
L3
NFB
MC
L1
L2
L3
Converter unit
NFB
FR-BIF
or
FR-BIF-H
Power
supply
Power
supply
Connections
MR-J2S-22KM(4) or smaller
MR-J2S-30KM(4) or larger
1. Cannot be connected to output side of the servo amplifier or converter unit.
2. Wiring should be as short as possible, and connect the wires to the terminal block of the unit.
3. Be sure to insulate the unused wire when using FR-BIF with the 1-phase wire.
Notes:
Unit: mm (inch) Unit: mm (inch)
Mounting Panel cutting dimensions
175 (6.89)
300 (11.81)
125 (4.92)
440 (17.32)30 (1.18) 160 (6.3)
Servo amplifier
or converter unit
Panel
Panel
Attachment
MR-ACN(P)MKMR-JACN15K MR-JACN22K
444 (17.48)
575 (22.64)15 (0.59)
605 (23.82)
DC
DD
DB
DA
4-M10 screw
MR-ACN(P)MKMR-JACNMK
DB
535 (21.06)
39.5 (1.56)
39.5 (1.56)
331 (13.03)
DC
DD
510 (20.08)
18 (0.71)
DA
4-M10 screw
Drill hole
Drill hole
260 (10.24)
11.5 (0.45)
3.2
(0.126)
155 (6.1)
105
(4.13)
145
(5.71)
20 (0.79)
35
(1.38)
400 (15.75)
Servo amplifier
Panel
Panel
145 (5.71)
68 (2.68)
Panel
MR-JACN15K
MR-JACN22K
MR-ACNP55K
MR-ACN30K
MR-ACN55K
DA DB DC DD
Model
Applicable servo amplifier
or converter unit
MR-J2S-11KA/B
MR-J2S-15KA/B
MR-J2S-11KA4/B4
MR-J2S-15KA4/B4
MR-J2S-22KA/B
MR-J2S-22KA4/B4
MR-HP30KA
MR-HP55KA4
MR-J2S-30KA4/B4
MR-J2S-30KA/B
MR-J2S-37KA/B
MR-J2S-37KA4/B4
MR-J2S-45KA4/B4
MR-J2S-55KA4/B4
Variable dimensions
455
(17.91)
406
(15.98)
360
(14.17)
440
(17.32)
385
(15.16)
336
(13.23)
290
(11.42)
370
(14.57)
205
(8.07)
156
(6.14)
110
(4.33)
190
(7.48)
290
(11.42)
326
(12.83)
345
(13.58)
360
(14.17)
203
(7.99)
236
(9.29)
255
(10.04)
270
(10.63)
Heat sink outside attachment (MR-(J)ACN)
By mounting the heat sink outside attachment on the converter unit or servo amplifier, the heat generating section can be mounted
outside the control box. This makes it possible to dissipate the unit’s heat to outside the box. Approx. 50% of the heating value can
be dissipated with this method, and the control box dimensions can be downsized.
Line noise filter (FR-BSF01, FR-BLF)
This filter is effective in suppressing radio noise emitted from the servo amplifier’s or converter unit’s power supply side or output
side, and high-frequency leakage current (zero-phase current). Especially effective in the 0.5 to 5MHz band.
110 (4.33)
22.5 (0.89)
95±0.5 (3.74±0.02)
65 (2.56)
65 (2.56)
4.5 (0.18)
2-ø5 (0.197)
ø33
(1.299)
130 (5.12)
85 (3.35)
160 (6.30)
180 (7.09)
ø7 (0.276)
80 (3.15)
31.5 (1.24)
2.3 (0.09)
35
(1.378)
7 (0.276)
<FR-BSF01>
MR-J2S-200M(4) or smaller
<FR-BLF>
MR-J2S-350M(4) or larger
External dimensions
Unit: mm (inch)
Connections
NFB
Line noise
filter
L1
L2
L3
MC
Power
supply
L1
NFB MC
L2
L3
Converter
unit
Line noise filters
Power
supply
Wind 3-phase wires an equal number of times in the same direction, and connect them to
the power supply side and output side of the servo amplifier or converter unit. The effect
of the filter on the power supply side rises as the number of winds increases, but generally
wind the wires four times each. If the wire is thick and hard to wind, use two or more filters,
and make sure that the total number of turns exceeds the above number. Make sure that
the number of turns on the output side is four times or less. Do not wind the grounding
(earth) wire together with the 3-phase wires. The effect of the filter will drop. Use a
separate wire for grounding.
MR-J2S-22KM(4) or smaller
MR-J2S-30KM(4) or larger
Blue
29 (1.14)
29 (1.14)
7
(0.28)
44 (1.73)
58 (2.28)
ø5 (0.197)
hole
Leakage current: 4mA
300 (11.8)
42 (1.65)
4 (0.16)
GreenRed
White
Applicable servo amplifier
Servo amplifier
Unit: mm (inch)
(0.44±0.02)
11.25±0.5