Auto data entry
Defines whether the cursor is to move automatically to the next manoeu-
vrable object.
Remove not used signals
Defines whether text lines that contain dynamic objects linked to timers,
counters and relays not used in the PLC system are shown on the display.
Does
not
concern data register types D and R.
Press [F2] to edit a textblock. To return to the previous menu press [Esc].
8.4.3 Dynamic objects
Dynamic objects can be found throughout textblocks. To create a dynamic
object. Select current object in the toolbox.
Digital
Digital objects are objects that only have two states, either one (ON) or
zero (OFF). They can be linked to the following types of signal: X, Y, M, S,
T, C. For timers (T) and Counters (C) we are referring to the output.
Note!
If the input picture of the object is shown, you can copy the latest configuration of the relevant
object type by pressing [Alt][F4]. Ensure that the object can fit onto the line it is written on.