Service manual

6
OUTLINES AND DIMENSIONS
7
MXZ-18TV -
MXZ-18TV -
E2
E1
Unit: mm
OUTDOOR UNIT
23
16
69
800
500
400
45.4
40
165
347.5
Air in
Air out
Air in
Drainage hole {33
Drainage
hole {33
113
300
152
155
43.6
34
17
90 65 65 65
34
17300
330
600
Handle
Handle
Liquid refrigerant pipe joint
Refrigerant pipe (flared) {6.35
Gas refrigerant pipe joint
Refrigerant pipe (flared) {9.52
Service
port
Bolt pitch for installation
100mm or more
100mm or more
200mm or more
350mm or more
However, either the
left / right sides or
back side should
be unobstructed.
Basically
unobstructed
Even if the right / left sides or
back side are vacant, the top
has to be at least 100mm
unobstructed.
WA
WA
WB
WA In case of poorly-ventilated place, the front
or the back has to be at least 200mm
unobstructed.
WB The wall may get dirty in case the air is
discharged toward it.
REQUIRED SPACE