Building Comfort Solutions Variable Refrigerant Flow Zoning Systems www.mehvac.
Mitsubishi Electric is a world leader in all types of quality products. Our consumer products, like high-definition televisions and home theater systems, have won awards for innovation and quality. Semi-conductors, opto-electronics devices, communication products, power generation systems, and, of course, heating and air-conditioning systems are all a part of the global Mitsubishi Electric family. Quality describes the products engineered and manufactured by Mitsubishi Electric.
Good for the environment and your bottom line. • Eco-friendly refrigerant: Environmentally-friendly R410A refrigerant offers zero Ozone Depletion Potential (ODP) and allows for higher heat transfer coefficient (COP). This innovative feature means a reduction in equipment size, a reduction in piping size and higher pressure for greater performance. Smaller equipment also means less impact on the environment at the end of the product’s life cycle.
CITY MULTI® VRFZ Systems: a user-friendly, ductless, or ducted commercial or residential comfort control system. (Variable Refrigerant Flow Zoning) Quality and reliability from a name you know: Mitsubishi Electric CITY MULTI is the first two-pipe, simultaneous cooling and heating system available in the United States and around the world. Our technology has a long and proven track record of quality and reliability around the world.
Ductless or ducted indoor units for ultimate flexibility A CITY MULTI outdoor unit can operate up to 50 ductless or ducted indoor units, depending on the outdoor unit, making the system ideal for virtually any type of application or any variety of applications within the same building. Do you need air conditioning on demand in a conference room? CITY MULTI provides that. Do you need a centralized system to cool or heat a large working area all day? CITY MULTI does that.
CITY MULTI® System Components OUTDOOR UNITS Mitsubishi Electric HVAC has an extensive outdoor unit line-up that can be tailored to any building design need.
INDOOR UNITS Mitsubishi Electric’s wide selection of different indoor unit styles allows you to choose the styles and size that meets your requirements for layout and design.
TECHNOLOGY OVERVIEW Low operating sound HIGH PERFORMANCE, MODULAR CITY MULTI® VRFZ SYSTEMS R2-Series / Y-Series / H2i™ Y-Series CITY MULTI outdoor units feature a new modular, compact chassis, design with a smaller installation footprint, low operating sound, easy piping / maintenance, longer line lengths, and lighter weight than available on previous models.
100% INVERTER-driven, like no other When an INVERTER-driven system is operating at partial load, the energy efficiency of the system is significantly higher than that of a standard fixed speed system. Fixed speed systems can only operate at 100%, however, partial load conditions prevail for the majority of the time. Therefore fixed speed systems cannot match the annual efficiencies of INVERTER-driven systems.
R2-SERIES OVERVIEW Simultaneous operation CITY MULTI® R2-Series: The First Two-pipe Heat Recovery System that Simultaneously Cools and Heats CITY MULTI systems provide simultaneous cooling and heating operation in fall, winter, and spring when the temperature drops below 65° F. So there is a significant number of days when the CITY MULTI R2-Series takes advantage of simultaneous operation, while maximizing comfort.
n the outdoor unit nstalled above indoor units) The advantages of the two-pipe CITY MULTI system become very obvious when it comes to the installation. The illustration below compares the minimum number of connections required for simultaneous cooling and heating system with four indoor units. The CITY MULTI system requires only 20 connections versus 58 for a three-pipe system.
R2-SERIES SPECIFICATIONS Model Name 208/230V PURY-P72THMU-A (-BS) PURY-P96THMU-A (-BS) PURY-P120THMU-A (-BS) 460V PURY-P72YHMU-A (-BS) PURY-P96YHMU-A (-BS) PURY-P120YHMU-A (-BS) 208/230V, 3-phase, 60Hz / 460V, 3-Phase, 60Hz Power Source Btu/h Cooling kW A Capacity *1 Btu/h Heating kW A 72,000 96,000 5.55 8.35 / 8.27 10.59 15.4 / 7.7 23.2 / 11.6 29.5 / 14.7 80,000 108,000 120,000 6.04 8.66 10.16 16.8 / 8.4 24.1 / 12.0 28.3 / 14.
PURY-P168TSHMU-A (-BS) *2 PURY-P192TSHMU-A (-BS) *2 PURY-P216TSHMU-A (-BS) *2 PURY-P240TSHMU-A (-BS) *2 With 2 PURY-P72THMU-A (-BS) *3 With 1 PURY-P72THMU-A (-BS) and 1 PURY-P96THMU-A (-BS) *3 With 2 PURY-P96THMU-A (-BS) *3 With 1 PURY-P96THMU-A (-BS) and 1 PURY-P120THMU-A (-BS) *3 With 2 PURY-P120THMU-A (-BS) *3 PURY-P144YSHMU-A (-BS) *2 PURY-P168YSHMU-A (-BS) *2 PURY-P192YSHMU-A (-BS) *2 PURY-P216YSHMU-A (-BS) *2 PURY-P240YSHMU-A (-BS) *2 With 2 PURY-P72YHMU-A (-BS) *3 With 1 PURY-P72YHMU-A
BC CONTROLLER SPECIFICATIONS for R2-Series and WR2-Series Systems (Heat Recovery) CMB-P-NU-G (Single BC) Specifications Model Name CMB-P105NU-G Number of Branches Power Source Power Input Current (208/230V) External Finish Dimensions CMB-P106NU-G 5 Cooling Heating W 73 W 86 33 208/230V, 1-phase, 60 Hz 112 40 138 53 CMB-P1016NU-G 13 16 178 66 217 86 106 A 0.35/0.32 0.41/0.37 0.54/0.49 0.66/0.60 0.86/0.77 1.04/0.94 A 0.16/0.14 0.19/0.17 0.25/0.23 0.32/0.29 0.41/0.37 0.
CMB-P-NU-GB, HB (Sub BC) Specifications Model Name CMB-P104NU-GB CMB-P1016NU-HB 8 16 4 Power Source OUTDOOR UNITS Number of Branches CMB-P108NU-GB 208/230V, 1-phase, 60 Hz Cooling Power Input W Heating Current (208/230V) 53 W 106 27 314 53 157 Cooling A 0.25/0.23 0.51/0.46 1.17/1.37 Heating A 0.13/0.12 0.25/0.23 0.59/0.
Y-SERIES OVERVIEW CITY MULTI Y-Series: The Two-pipe Zoned System designed for Heat Pump Operation ® Y-Series outdoor units are flexible enough to cool or heat up to 50 individual zones, maximizing building design options. New modular units feature a compact chassis, smaller installation footprint, low operating sound, easy piping and maintenance design, and are lightweight. Y-Series units are available in both 208/230V and 460V up to 30 tons for different applications.
Y-SERIES SPECIFICATIONS 208/230V PUHY-P72THMU-A (-BS) PUHY-P96THMU-A (-BS) PUHY-P120THMU-A (-BS) 460V PUHY-P72YHMU-A (-BS) PUHY-P96YHMU-A (-BS) PUHY-P120YHMU-A (-BS) 208/230V, 3-Phase, 60Hz / 460V, 3-Phase, 60Hz Power Source Btu/h Cooling kW A Capacity *1 Btu/h Heating kW A 72,000 96,000 5.27 8.42 10.11 14.6 / 7.3 23.4 / 11.7 28.1 / 14.0 80,000 108,000 120,000 5.68 8.63 9.26 15.8 / 7.9 24.0 / 12.0 25.8 / 12.
Y-SERIES SPECIFICATIONS (continued) PUHY-P144TSHMU-A (-BS) *2 PUHY-P168TSHMU-A (-BS) *2 PUHY-P192TSHMU-A (-BS) *2 PUHY-P216TSHMU-A (-BS) *2 PUHY-P240TSHMU-A (-BS) *2 With 2 PUHY-P72THMU-A (-BS) *3 With 1 PUHY-P72THMU-A (-BS) and 1 PUHY-P96THMU-A (-BS) *3 With 1 PUHY-P72THMU-A (-BS) and 1 PUHY-P120THMU-A (-BS) *3 With 1 PUHY-P96THMU-A (-BS) and 1 PUHY-P120THMU-A (-BS) *3 With 2 PUHY-P120THMU-A (-BS) *3 PUHY-P144YSHMU-A (-BS) *2 PUHY-P168YSHMU-A (-BS) *2 PUHY-P192YSHMU-A (-BS) *2 PUHY-P216YSHMU-
PUHY-P264TSHMU-A (-BS) *2 PUHY-P288TSHMU-A (-BS) *2 PUHY-P312TSHMU-A (-BS) *2 PUHY-P336TSHMU-A (-BS) *2 PUHY-P360TSHMU-A (-BS) *2 With 2 PUHY-P72THMU-A (-BS) and 1 PUHY-P120THMU-A (-BS) *3 With 1 PUHY-P72THMU-A (-BS), 1 PUHY-P96THMU-A (-BS) , and 1 PUHY-P120THMU-A *3 With 1 PUHY-P72THMU-A (-BS) and 2 PUHY-P120THMU-A (-BS) *3 With 1 PUHY-P96THMU-A (-BS) and 2 PUHY-P120THMU-A (-BS) *3 With 3 PUHY-P120THMU-A (-BS) *3 Model Name PUHY-P264YSHMU-A (-BS) *2 PUHY-P288YSHMU-A (-BS) *2 PUHY-P312YSHMU-A (-
H2i™ Y-SERIES OVERVIEW The heat pump as you knew it is history. The Hyper-Heating INVERTER (H2i™) technology* is exclusively from Mitsubishi Electric and is available in select CITY MULTI® VRFZ models. The cooling and heating success of our INVERTER heat pump systems is well documented. But we did not stop there. We decided to redefine the heat pump even more. Imagine sitting toasty warm inside while it is -13˚ F outside or realizing full heating capacity at 5˚ F outdoor ambient.
H2i Y-SERIES SPECIFICATIONS PUHY-HP96THMU-A (-BS) Power Source Capacity *1 Power Input Current (208/230) Btu/h 72,000 96,000 144,000 192,000 Btu/h 80,000 108,000 160,000 216,000 Cooling kW 5.90 8.73 12.15 *3 17.98 *3 Heating kW 6.28 9.13 12.94 *3 18.81 *3 Cooling A 18.2-16.5 27.0-24.4 37.5-33.9 *3 55.5-50.2 *3 Heating A 19.4-17.6 28.2-25.5 40.0-36.1 *3 58.1-52.
S-SERIES OVERVIEW CITY MULTI® S-Series: Heat Pump solutions in the home or small office The CITY MULTI S-Series is a singlephase heat pump system perfect for light commercial or large residential applications. Available in 36,000 or 48,000 Btu/h, the S-Series can provide cooling or heating for up to eight individual zones. The CITY MULTI S-Series for homes and small offices offers all the features and benefits of our large commercial CITY MULTI Y-Series.
S-SERIES SPECIFICATIONS PUMY-P36NHMU(-BS) Power Source OUTDOOR UNITS Model Name PUMY-P48NHMU(-BS) 208/230V, 1-phase, 60Hz Capacity *1 Power Input Current (208-230V) Cooling Btu/h 36,000 48,000 Heating Btu/h 40,000 54,000 Cooling kW 3.22 4.97 Heating kW 2.93 4.88 Cooling A 14.2-15.7 24.0-21.7 Heating A 12.9-14.2 23.6-21.3 Type x Quantity Fan Propeller Fan x 2 Airflow Rate CFM Motor Output kW 3,530 0.
W-SERIES OVERVIEW CITY MULTI W-Series: Water-Source Systems that Simultaneously Cool and Heat or provides Heat Pump Operation Now you can control temperature in every room, on every floor, in every building with Mitsubishi Electric’s CITY MULTI systems. It’s an innovative concept that is transforming the way the industry approaches building design, construction, and renovation; it’s based on the understanding that every building has its own unique characteristics and challenges.
Unit Exterior Unit Interior Multi-circuited tubein-tube condenser Control panel Reversing valve Inverter cooler Condenser circuit control valve block Inverter-driven scroll compressor Suction accumulator Building Example WATER-SOURCE UNITS LOSSNAY® ERV Water-source VRFZ Unit *The water circuit is closed-loop.
W-SERIES SPECIFICATIONS WR2-Series Heat Recovery Water-Source Unit (Requires BC Controller) Model PQRY-P72TGMU-A Power Source Capacity *1 Power Input Current (208/230V) Cooling Btu/h 72,000 96,000 Heating Btu/h 85,000 107,000 Cooling kW 5.25 6.95 Heating kW 5.44 6.84 Cooling A 16.19 - 14.64 21.43 - 19.38 Heating A 16.77 - 15.17 21.09 - 19.07 Type Compressor INVERTER-driven Scroll Hermetic Motor Output kW 5.0 6.
WY-Series Heat Pump Water-Source Unit Model PQHY-P72TGMU-A Power Source Capacity *1 Power Input Current (208/230V) Cooling Btu/h 72,000 96,000 Heating Btu/h 85,000 107,000 Cooling kW 5.25 6.95 Heating kW 5.44 6.84 Cooling A 16.19 - 14.64 21.43 - 19.38 Heating A 16.77 - 15.17 21.09 - 19.07 Type Compressor INVERTER-driven Scroll Hermetic Motor Output kW Case Heater W 5.0 6.0 57 (230V) Lubricant Circulating Water MEL32 Water Flow Rate GPM (L/s) 20.1 (1.
CITY MULTI® INDOOR UNITS Multiple choices for indoor units In today’s modern building practices, the interior mechanical components are all designed for ultimate comfort and functionality. Aesthetics are also an important aspect of that comfort. CITY MULTI VRFZ systems offer many sleek styles of ductless or ducted indoor units for various applications. Each indoor unit gives you ultimate zoning flexibility in each space.
PVFY: Vertical Air Handler The PVFY vertical air handler is designed for closet or attic applications. The side drain pan makes it possible to use in a horizontal, left facing, position. With all the components, including a linear expansion valve (LEV) and controls pre-mounted within the cabinet for easy installation, this unit is ideally suited for use in retrofit and new building applications.
PKFY OVERVIEW (wall mounted) Elegant design and compact dimensions ideal for offices, classrooms, and residential uses. PKFY-P-NAMU-E PKFY-P-NGMU-E PKFY-P-NFMU-E Capacity range: 6,000 to 30,000 Btu/h A wide selection for your design and performance needs Whatever the size or shape of your room, there is a Mitsubishi Electric PKFY unit that is just right, delivering the style and performance you demand and deserve. PKFY units mount high on the wall and blend in beautifully into any space.
PKFY-P-N*MU-E SPECIFICATIONS PKFY-P-NAMU-E Model Name Power Source Cooling Capacity Heating Capacity Power Consumption Cooling Heating Current Cooling Heating External Finish (Munsell No.
PLFY OVERVIEW (ceiling-recessed) Perfect airflow to meet your needs with four-way control. Ceiling applications The PLFY-NBMU has a unit height of only 10-1/4” or 11-3/4”, depending on the model, and provides great looking installations in low-ceiling areas with very limited space. PLFY-NBMU 10 1/4” or 113/4” Capacity range: 12,000 – 36,000 Btu/h PLFY-NCMU PLFY-Series indoor units offer unequaled flexibility of installation. Their compact ceiling-recessed design makes them easy to install and operate.
Corner-pocket design simplifies maintenance and installation Access the unit through the corner pockets equipped on all four corners of the grille to complete installation, maintenance work, and height adjustment. Easy maintenance, long-life filter The washable filter provides about 2,500 hours of use in a normal office environment before cleaning is needed. The PLFY-NBMU is also available with an optional multi-function casement that allows for additional ventilation air and better filtration.
PLFY-P-NBMU-E SPECIFICATIONS Model Name PLFY-P12NBMU-E PLFY-P15NBMU-E Power Source PLFY-P18NBMU-E 208/230V, 1-phase, 60Hz Cooling Capacity Btu/h *1 12,000 15,000 18,000 Heating Capacity Btu/h *1 13,500 17,000 20,000 Power Consumption Current Cooling W 30 40 50 Heating W 20 30 40 Cooling A 0.22 0.29 0.36 Heating A 0.14 0.22 0.29 External Finish Color (Munsell No.) Dimensions Net Weight *2 Grille 6.4Y 8.9/0.
PLFY-P-NCMU-E SPECIFICATIONS Model Name PLFY-P08NCMU-E Power Source PLFY-P12NCMU-E PLFY-P15NCMU-E 208 230V, 1-phase, 60Hz Cooling Capacity Btu/h *1 8,000 12,000 15,000 Heating Capacity Btu/h *1 9,000 13,500 17,000 Power Consumption Current Cooling W 50 Heating W 50 60 Cooling A 0.23 0.28 Heating A 0.23 External Finish (Munsell No.) 60 0.28 Grille: White (6.4Y 8.9/0.
PMFY OVERVIEW (ceiling-recessed cassette) Compact and lightweight one way airflow, perfect for limited ceiling space applications. Capacity range: 6,000 – 15,000 Btu/h Quiet operation Newly-developed airflow control technology operates as low as 27 dB(A) for industry-leading quiet performance. Ideal for small spaces The PMFY models are one-way, ceiling-recessed cassette units perfect for shallow ceiling spaces. The PMFY unit moves air in one direction and can introduce ventilation air.
PMFY-P-NBMU-E SPECIFICATIONS Model PMFY-P06NBMU-E PMFY-P08NBMU-E Power Source PMFY-P12NBMU-E PMFY-P15NBMU-E 208/230V, 1 Phase, 60Hz Cooling Capacity Btu/h *1 6,000 8,000 12,000 15,000 Heating Capacity Btu/h *1 6,700 9,000 13,500 17,000 50 Power Consumption Cooling W 40 40 40 Heating W 40 40 40 50 Cooling A 0.20 0.20 0.21 0.26 Heating A 0.20 0.20 0.21 0.26 Current External Finish Dimensions Net Weight *2 Grille: Munsell 0.98Y 8.99/0.
already taxed cooling or heating load. PCFY OVERVIEW (ceiling-suspended) PCFY-P-NGMU-E The ceiling-suspended compact dimensions areideal idealfor forr Ceiling-suspended type's compact dimensions Compact design ideal for classrooms, restaurants, Powerfuland cooling and heating performance is what the PCFY-Series is all about. This ceiling-suspen stores. unit delivers enough cold or hot air to make any space more comfortable.
PCFY SPECIFICATIONS Model Name PCFY-P15NGMU-E PCFY-P24NGMU-E Power Source PCFY-P30NGMU-E PCFY-P36NGMU-E 208/230V, 1-phase, 60Hz Cooling Capacity Btu/h *1 15,000 24,000 30,000 36,000 Heating Capacity Btu/h *1 17,000 27,000 34,000 40,000 Cooling W 80 90 230 270 Heating W 80 90 230 270 Cooling A 0.4 0.45 1.12 1.32 Heating A 0.4 0.45 1.12 1.32 Power Consumption Current External Finish Color (Munsell No.
PDFY/PEFY OVERVIEW (ceiling-concealed) Flexible design allows elegant interior layout. Capacity range: 6,000 – 96,000 Btu/h Designed to be neither seen nor heard, just to perform The PDFY and PEFY models are high-performance, ceiling-concealed, ducted indoor units. In fact, if it weren’t for the constantly comfortable environment these units deliver, you might not even know they were there. The ducted fan coils are designed to be installed above the ceiling, hidden from public view.
PDFY-P-NMU-E SPECIFICATIONS (standard) Model Name PDFY-P06NMU-E PDFY-P08NMU-E Power Source PDFY-P12NMU-E PDFY-P15NMU-E PDFY-P18NMU-E 208/230V, 1-phase, 60Hz Cooling Capacity *1 Btu/h 6,000 8,000 12,000 15,000 18,000 Heating Capacity *1 Btu/h 6,700 9,000 13,500 17,000 20,000 Power Consumption Current Cooling W 120 120 120 150 150 Heating W 120 120 120 150 150 Cooling A 0.61/0.68 0.61/0.68 0.61/0.68 0.77/0.85 0.77/0.85 Heating A 0.61/0.68 0.61/0.68 0.61/0.
PEFY-P-NMSU-E SPECIFICATIONS Model Name PEFY-P06NMSU-E* 1 LOW PROFILE PEFY-P08NMSU-E PEFY-P12NMSU-E Power Source Cooling Capacity *2 Btu/h Heating Capacity *2 Power Consumption Current Cooling 6,000 8,000 12,000 13,500 Btu/h 6,700 9,000 W 50/50 60/60 Net Weight 18,000 24,000 17,000 20,000 27,000 90/90 120/120 W 30/30 40/40 70/70 100/100 A 0.42/0.41 0.51/0.49 0.56/0.53 50/50 0.57/0.55 0.74/0.70 0.98/0.93 Heating A 0.32/0.31 0.41/0.39 0.46/0.43 0.47/0.45 0.64/0.
PEFY-P-NMHU-E SPECIFICATIONS Model Name ALTERNATE HIGH STATIC OPTION PEFY-P15NMHU-E PEFY-P18NMHU-E Power Source PEFY-P24NMHU-E PEFY-P27NMHU-E PEFY-P30NMHU-E 30,000 208/230V, 1-phase, 60Hz Cooling Capacity *1 Btu/h 15,000 18,000 24,000 27,000 Heating Capacity *1 Btu/h 17,000 20,000 27,000 30,000 34,000 Cooling W 188/207 188/207 245/270 270/297 326/360 Heating W 188/207 188/207 245/270 270/297 326/360 Cooling A 0.96/1.06 0.96/1.06 1.25/1.38 1.37/1.51 1.66/1.
PFFY OVERVIEW (floor-standing) Effective use of perimeter space. Exposed Type PFFY-P-NEMU-E Concealed Type PFFY-P-NRMU-E Compact unit provides simple, effective air-conditioning in perimeter zones Less than nine inches deep, these PFFY floor-standing units are easy to install in peripheral spaces, yet offer highly efficient air-conditioning performance. Since these are floor-standing models, they are perfect for spaces with little or no ceiling space.
PFFY-P-NEMU/NRMU-E SPECIFICATIONS PFFY-P-NEMU-E Model Power Source Cooling Capacity Heating Capacity Power Cooling Consumption Heating Current Cooling Heating External Finish (Munsell No.
PVFY OVERVIEW (vertical air handler) Ideal for closet or attic applications. The vertical air handler is ideal for installations in closets or equipment rooms where space is limited. The air handler also has a side drain pan allowing it to be installed in a horizontal left position. The vertical air handler can be connected to a system with all other CITY MULTI indoor units for complete system design flexibility. Other features include: • An adjustable blower static pressure from a factory set 0.30” W.G.
PVFY-P-E00A SPECIFICATIONS Model Name PVFY-P12E00A PVFY-P18E00A PVFY-P24E00A Power Source PVFY-P30E00A PVFY-P36E00A PVFY-P48E00A PVFY-P54E00A 208/230V, 1-phase, 60Hz Cooling Capacity Btu/h *1 12,000 18,000 24,000 30,000 36,000 48,000 54,000 Heating Capacity Btu/h *1 13,500 20,000 27,000 34,000 40,000 54,000 60,000 Power Consumption Current Dimensions Net Weight Cooling kW 0.17 / 0.17 0.28 / 0.28 0.26 / 0.26 0.38 / 0.38 0.32 / 0.32 0.36/0.36 0.41/0.41 Heating kW 0.
CITY MULTI® CONTROLS NETWORK Our CITY MULTI Controls Network makes it easy to manage your building The CITY MULTI Controls Network (CMCN) manages up to 2,000 indoor units from a single networked PC in terms of operation, monitoring, scheduling (daily, weekly, and yearly), error email, personal browser, tenant billing, and maintenance diagnostic information. The CMCN puts individual, personalized comfort in the hands of the tenants and the building manager.
CONTROLS NETWORK SPECIFICATIONS GB-24 24 24 GB-24 *7 CONTROLS *7. GB-24 license registration is required to monitor and operate the units by browser and TG-2000.
CENTRALIZED CONTROLLER AG-150 Option: Black surface cover. PAC-YG71CBL M-NET AG-150 PAC-SC51KUA ETHERNET DIDO Board 79 ˚F 79 ˚F 82 ˚F Function Description Touch Screen 9" high resolution color touch screen Max No. of Indoor Units Up to 50 indoor units can be connected ON/OFF On/Off operation for a single group and batch operation Operation Mode Cool/Dry/Auto/Fan/ Heat Auto mode is available with only R2 and WR2 systems Temperature Setting Sets the temperature for a single group.
CENTRALIZED CONTROLLER GB-50 M-NET GB-50 PAC-SC51KUA ETHERNET DIDO Board 79 ˚F 79 ˚F 82 ˚F Function Description Max No. of Indoor Units Up to 50 indoor units can be connected ON/OFF On/Off operation for a single group and batch operation Operation Mode Cool/Dry/Auto/Fan/ Heat. Auto mode is available with only R2 and WR2 systems Temperature Setting Sets the temperature for a single group.
CENTRALIZED CONTROLLER GB-24 GB-24 PAC-SC51KUA DIDO Board ETHERNET 79 ˚F 79 ˚F 82 ˚F Function Description Max No. of Indoor Units Up to 24 indoor units can be connected ON/OFF On/Off operation for a single group and batch operation Operation Mode Cool/Dry/Auto/Fan/ Heat. Auto mode is available with only R2 and WR2 systems Temperature Setting Sets the temperature for a single group.
Software Options for Centralized Controllers The Centralized Controllers support operations that supersede control of the remote controllers and include system configuration, daily/weekly scheduling, operation, and malfunction monitoring. All Centralized Controllers are equipped with an RJ-45 Ethernet port to support interconnection with a networked PC via a closed/ direct Local Area Network (LAN).
CITY MULTI® CONTROLLERS Deluxe MA Remote Controller (PAR-21MAA) • Features user-friendly multilingual operation and monitoring. • Controls up to 16 indoor units in a single group. • User Functions: Allows user to set: - On/Off - operation modes of Cool, Heat, Dry, Fan, or Auto (R2-Series only), ventilation - set temperature from 57° F – 87° F, depending on operation mode and indoor unit. Example - fan speed setting • Diagnostics: Displays four-digit error code.
Wireless MA Remote Controller (PAR-FL32MA) and Receiver (PAR-FA32MA) • Features user-friendly operation and monitoring. • Controls up to 16 indoor units in a single group. • User Function: Allows user to set: - On/Off - operation modes of Cool, Heat, Dry, Fan or Auto (R2-Series only) - set temperature from 57˚ F – 87˚ F, depending on operation mode and indoor unit.
I/O CONTROL BOARD ETHERNET AG150 PAC-YG66DCA PAC-YG63DCA ! EQUIPMENT 1 EQUIPMENT 2 SENSOR 1 PAC-YG66DCA Digital Input Digital Output (DIDO) Control Board The DIDO controller used in conjunction with a AG-150, GB-50, or GB-24 Centralized Controller can control and monitor third party general equipment.
TG-2000™ INTEGRATED SYSTEM SOFTWARE The TG-2000 integrated system software enables the user to control multiple AG-150/ GB-50/GB-24 controllers and provide enhanced functions from a single, dedicated networked PC configured with the TG-2000 software and AG-150/GB-50/ GB-24 software licenses. The TG-2000 configured PC is capable of controlling up to 2,000 indoor units with the AG-150/GB-50/GB-24 Centralized Controllers.
System Integration: LonWorks® and BACnet® The CMCN supports integration with Building Management Systems (BMS) via our LonWorks® and BACnet® interfaces. LonWorks® The Mitsubishi Electric HVAC LonWorks® interface, LMAP03U, supports up to 50 indoor units with a variety of network variables on a per indoor unit basis. Input variables include, but are not limited to, On/Off, Operation Mode, Fan Speed, Prohibit Remote Controller, and Filter Sign Reset.
Lossnay® Energy Recovery Ventilators Lossnay energy recovery ventilators provide outdoor air solutions for indoor environmental quality. See the Lossnay Technical Brochure for complete information. Bypass auto ventilation standard Model LGH-F300RX3-E LGH-F600RX3-E CFM 300 600 Model LGH-F470RX3-E LGH-F1200RX3-E CFM 470 1,200 Improved sound attenuation makes Lossnay® units quiet enough for places where silence is a must, such as meeting rooms and libraries.
Maintenance Tool Overview Mitsubishi’s easy-to-use, Windows® based Maintenance Tool software allows technicians to monitor and collect CITY MULTI system data and control various functions of the system for maintenance purposes. System monitoring is accomplished through direct connection between your PC and the M-NET bus line using the MN-Converter or by connecting remotely to a system centralized controller such as the AG-150 or GB-50 via a TCP/IP network, or via a remote dialup connection.
The system connection information view shows a snapshot of the components connected to the system, identifying each component’s type and system address. Through a simple series of clicks, the user can monitor the critical data points for each component, manipulate the control features and operate each component, or view each component’s malfunction log.
Design Tool Software Overview Mitsubishi’s Design Tool software makes designing with CITY MULTI quick and easy. The designer just needs to drag and drop components to complete the design. The program has built in safeguards against exceeding limitations and shows if there is an error. Assuring line lengths, maximum connected capacities, component selection, control scheme, etc. are within the system requirements.
The system is summarized in an Excel (.xls). Included are all the design parameters, equipment list, line sizes, indoor unit operating capacities, additional refrigerant based on the line lengths, control scheme with addressing and much, much more. The Excel-based output simplifies quoting a job and tracking equipment lists. SOFTWARE With the help of AutoCAD* or AutoCAD LT* installed on the computer, a schematic (.dwg format) is generated that includes all the requirements to make installation a breeze.
Mitsubishi Electric Air Conditioning & Refrigeration Systems Works acquired ISO 9001 certification under Series 9000 of the international Standard Organization (ISO), based on a review of quality warranties for the production of refrigeration and air conditioning equipment. ISO Authorization System The ISO 9000 series is a plant authorization system relating to quality warranties as stipulated by the ISO.