Specifications
18
Also consider operation sound
• Do not put an object around the air outlet of the outdoor unit. It may cause lowering of capacity or increase operating sound.
• If abnormal sound is heard during operation, consult your dealer.
Relocation
• When the air conditioner is to be removed or reinstalled because of rebuilding, moving, etc., special techniques and work are required.
Warning:
Repair or relocation should not be done by the customer.
If this is done incorrectly, it may cause a fire, electric shock, injury by dropping of the unit, water leakage, etc. Consult your dealer.
Disposal
• To dispose of this product, consult your dealer.
If you have any question, consult your dealer.
12. Installation, relocation and inspection
Model
Function
Power supply
Capacity
kW
BTU/h
Input kW
Indoor unit
Airflow (Lo-Me-Hi) CMM
Noise level (Lo-Me-Hi) dB
Weight kg
Outdoor unit
Noise level dB
Refrigerant R410A kg
Weight kg
SLZ-KA25VA (L)
Cooling Heating
2.5 3.0
8,500 10,200
0.69 0.83
SLZ-KA25VA (L)
8-9-10
28-31-37
16.5 + Grille 3
SUZ-KA25VA
46
0.90
33
SLZ-KA35VA (L)
Cooling Heating
~/N, 230V, 50Hz
3.5 4.0
11,900 13,600
1.06 1.10
SLZ-KA35VA (L)
8-9-11
29-33-38
16.5 + Grille 3
SUZ-KA35VA
48
1.05
35
SLZ-KA50VA (L)
Cooling Heating
4.6 5.0
15,700 17,100
1.63 1.55
SLZ-KA50VA (L)
8-9-11
30-34-39
16.5 + Grille 3
SUZ-KA50VA
55
1.6
53
Notes: 1. Rating conditions (cooling) Indoor : 27°C DB, 19°C WB Outdoor : 35°C DB
2. Rating conditions (heating) Indoor : 20°C DB Outdoor : 7°C DB, 6°C WB
3. Specifications subject to change without notice.
Guaranteed operating range
Indoor
Outdoor
KA25, KA35
KA50, KA60, KA71
Cooling
Upper limit 32°C DB, 23°C WB 46°C DB, – 43°C DB, –
Lower limit 21°C DB, 15°C WB -10°C DB, –
Heating
Upper limit 27°C DB, – 24°C DB, 18°C WB
Lower limit 20°C DB, – -10°C DB, -11°C WB
Units should be installed by licensed electric contractor accordingly to local code requirement.
13. Specifications
SEZ-KA35VA
Cooling Heating
3.5 4.0
11,900 13,600
1.06 1.10
SEZ-KA35VA
10-13
Std. : 30 (3)
Max. : 50 (5)
30-35
33.5
SUZ-KA35VA
48
1.05
35
Model
Function
Power supply
Capacity
kW
BTU/h
Input kW
Indoor unit
Airflow (Lo-Hi) CMM
Ext. static
Pa (mmAq)
pressure
Noise level (Lo-Hi) dB (A)
Weight kg
Outdoor unit
Noise level dB (A)
Refrigerant R410A kg
Weight kg
SEZ-KA50VA
Cooling Heating
5.0 5.9
17,100 20,100
1.78 1.84
SEZ-KA50VA
12-17
Std. : 30 (3)
Max. : 50 (5)
31-39
33.5
SUZ-KA50VA
55
1.6
53
SEZ-KA60VA
Cooling Heating
5.5 6.9
18,800 23,500
1.96 2.45
SEZ-KA60VA
12-20
Std. : 30 (3)
Max. : 50 (5)
32-43
33.5
SUZ-KA60VA
55
1.8
53
SEZ-KA71VA
Cooling Heating
7.1 8.1
24,200 27,600
2.46 2.36
SEZ-KA71VA
12-20
Std. : 30 (3)
Max. : 50 (5)
32-43
35
SUZ-KA71VA
55
2.0
58
~/N, 230V, 50Hz