Specifications

18
Also consider operation sound
Do not put an object around the air outlet of the outdoor unit. It may cause lowering of capacity or increase operating sound.
If abnormal sound is heard during operation, consult your dealer.
Relocation
When the air conditioner is to be removed or reinstalled because of rebuilding, moving, etc., special techniques and work are required.
Warning:
Repair or relocation should not be done by the customer.
If this is done incorrectly, it may cause a fire, electric shock, injury by dropping of the unit, water leakage, etc. Consult your dealer.
Disposal
To dispose of this product, consult your dealer.
If you have any question, consult your dealer.
12. Installation, relocation and inspection
Model
Function
Power supply
Capacity
kW
BTU/h
Input kW
Indoor unit
Airflow (Lo-Me-Hi) CMM
Noise level (Lo-Me-Hi) dB
Weight kg
Outdoor unit
Noise level dB
Refrigerant R410A kg
Weight kg
SLZ-KA25VA (L)
Cooling Heating
2.5 3.0
8,500 10,200
0.69 0.83
SLZ-KA25VA (L)
8-9-10
28-31-37
16.5 + Grille 3
SUZ-KA25VA
46
0.90
33
SLZ-KA35VA (L)
Cooling Heating
~/N, 230V, 50Hz
3.5 4.0
11,900 13,600
1.06 1.10
SLZ-KA35VA (L)
8-9-11
29-33-38
16.5 + Grille 3
SUZ-KA35VA
48
1.05
35
SLZ-KA50VA (L)
Cooling Heating
4.6 5.0
15,700 17,100
1.63 1.55
SLZ-KA50VA (L)
8-9-11
30-34-39
16.5 + Grille 3
SUZ-KA50VA
55
1.6
53
Notes: 1. Rating conditions (cooling) Indoor : 27°C DB, 19°C WB Outdoor : 35°C DB
2. Rating conditions (heating) Indoor : 20°C DB Outdoor : 7°C DB, 6°C WB
3. Specifications subject to change without notice.
Guaranteed operating range
Indoor
Outdoor
KA25, KA35
KA50, KA60, KA71
Cooling
Upper limit 32°C DB, 23°C WB 46°C DB, 43°C DB,
Lower limit 21°C DB, 15°C WB -10°C DB,
Heating
Upper limit 27°C DB, 24°C DB, 18°C WB
Lower limit 20°C DB, -10°C DB, -11°C WB
Units should be installed by licensed electric contractor accordingly to local code requirement.
13. Specifications
SEZ-KA35VA
Cooling Heating
3.5 4.0
11,900 13,600
1.06 1.10
SEZ-KA35VA
10-13
Std. : 30 (3)
Max. : 50 (5)
30-35
33.5
SUZ-KA35VA
48
1.05
35
Model
Function
Power supply
Capacity
kW
BTU/h
Input kW
Indoor unit
Airflow (Lo-Hi) CMM
Ext. static
Pa (mmAq)
pressure
Noise level (Lo-Hi) dB (A)
Weight kg
Outdoor unit
Noise level dB (A)
Refrigerant R410A kg
Weight kg
SEZ-KA50VA
Cooling Heating
5.0 5.9
17,100 20,100
1.78 1.84
SEZ-KA50VA
12-17
Std. : 30 (3)
Max. : 50 (5)
31-39
33.5
SUZ-KA50VA
55
1.6
53
SEZ-KA60VA
Cooling Heating
5.5 6.9
18,800 23,500
1.96 2.45
SEZ-KA60VA
12-20
Std. : 30 (3)
Max. : 50 (5)
32-43
33.5
SUZ-KA60VA
55
1.8
53
SEZ-KA71VA
Cooling Heating
7.1 8.1
24,200 27,600
2.46 2.36
SEZ-KA71VA
12-20
Std. : 30 (3)
Max. : 50 (5)
32-43
35
SUZ-KA71VA
55
2.0
58
~/N, 230V, 50Hz