4.2 Basic Adjustment
Use MT Tools 2000
1
(Vers.103 Ed.02 or higher) to set all the parameters.
4.2.1 Power Adjustment
Each mobile is adjusted in the factory and the TX parameters (Power Control Level values and ramping values)
are stored in the Flash Data (IC202)
About the adjustment value of TX Power, see the following table.
E-GSM DCS
Ch-62
PCL
Power Level
(dBm)
tolerance Ch-698
PCL
Power Level
(dBm)
tolerance
5
33 +/-2dB
0
30 +/-2dB
6
31 +/-3dB
1
28 +/-3dB
7
29 +/-3dB
2
26 +/-3dB
8
27 +/-3dB
3
24 +/-3dB
9
25 +/-3dB
4
22 +/-3dB
10
23 +/-3dB
5
20 +/-3dB
11
21 +/-3dB
6
18 +/-3dB
12
19 +/-3dB
7
16 +/-3dB
13
17 +/-3dB
8
14 +/-3dB
14
15 +/-3dB
9
12 +/-4dB
15
13 +/-3dB
10
10 +/-4dB
16
11 +/-5dB
11
8 +/-4dB
17
9 +/-5dB
12
6 +/-4dB
18
7 +/-5dB
13
4 +/-4dB
19
5 +/-5dB
14
2 +/-5dB
15
0 +/-5dB
4.2.2 RSSI control.
Set your radiocommunication tester at a given reference and check RSSI :
REF Gene RSSI
-83.5 dBm 27 +/- 4
-60.5 dBm 50 +/- 4
1
See Manual FA9M0640