RS-232 Connection Cable
Computer (DB9) Printer (DB25)
Signal Pin No. Pin No. Signal
RXD 2 2 TXD
TXD 3 3 RXD
DR 4 6 DSR
SG 5 7 GND
DR 6 20 DTR
RS 7 5 CTS
CS 8 4 RTS
FG 9 1 FG
#9 on the 9 Pin end of the cable is typically tied to the Shield.
This is just an example. Make sure to check the connection type
for the using equipment.
CONNECTION WITH RS-232C EQUIPMENT
This unit can controlled through a RS-232C port with custom software. (Image data can not be input.)
For the protocol, consult your dealer.
Make sure to turn off the power before setting.
2 2
2 2
2
RS-232C TERMINAL SIGNAL
REMOTE
RS-232C
S-VIDEO IN
S-VIDEO OUT
R
G/G+SYNC B Y/SYNC
IN
VIDEO
75
75/HIGH
AC LINE
OUT
75/HIGH
75
75
75
75
HIGH
HIGH
HIGH
HIGH
ON
OFF
POWER
HIGH
IMPEDANCE
RGB
75
75/HIGH
HIGH
SYNC
To RS-232C terminal
(RS-232C)
To RS-232C treminal
VCP
Equipment with RS-232C
25
14
13
Pin number
1
Pin No. Signal line name Description Directions
1 FG Protective ---
2 TXD Transmitted data Output
3 RXD Received data Input
4 RTS Request to send Output
5 CTS Clear to send Input
6 DSR Data set ready Input
7 GND Signal ground ---
20 DTR Data terminal ready Output
RS-232 Connection Cable (Cross-
over cable)
(DB25) (DB25)
Signal Pin No. Pin No. Signal
FG 1 1 FG
TXD 2 2 TXD
RXD 3 3 RXD
RTS 4 4 RTS
CTS 5 5 CTS
DSR 6 6 DSR
DTR 20 20 DTR
GND 7 7 GND
11
11
1
Connect this unit and RS-232C equipment
with a crossover cable.
22
22
2
Set the baud rate according to the equipment
to be connected.
Press MENU button, then press STOP button
on remote control unit.
SERVICE MENU is displayed.
33
33
3
Press
}}
}}
}
button to select RS232C.