MAIN
ON
OFF
AC IN
~
100-240V
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
1
ALARM IN
RESET
OUT IN
AUDIO
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
CLOCK ADJ
REC
EMERGENCY
MODE OUT 1
MODE OUT 2
MODE OUT 3
MODE OUT 4
MODE OUT 5
CALL OUT
CALL OUT GND
MAX 30mA
DC 5V OUT
GND
RS-232C
REMOTE
OUT
IN
CAMERA
MIC
Y/C
VIDEO
OUTPUT A
OUTPUT B
OUT
IN
ETHERNET
SCSI
SENDRECEIVE
GND
T
T
R
R
GND
GND
RS-485/
TRM
TRM
RS-422
14 15 16
13
129 108 11
7
1
2
3
5
4
6
REC terminal
Input terminal to start recording. Not available dur-
ing timer recording.
EMERGENCY terminal
Input terminal initiating EMERGENCY recording
mode.
MODE OUT 1 ~ MODE OUT 5 terminals
Output terminal to indicate the units current mode.
Select the units condition by MODE OUT 1 ~ MODE
OUT 5 setting in the <REAR TERMINAL SETTINGS>
menu.
CALL OUT terminal / CALL OUT GND terminals
This is the ISOLATION output terminal. Information
that can be transmitted externally consists of CALL
OUT settings made on the <REAR TERMINAL SET-
TINGS> menu screen as well as fixed output set-
tings.
DC 5V OUT terminal
Will only output when both the MAIN switch and
POWER button are ON. The maximum electric cur-
rent is 30mA.
14. RS-232C connector
This connector is used to connect to host device with
RS-232C connector. This unit can be controlled by
another device through this connector.
15. ETHERNET connector
Use a 10BASE-T cable to connect to the Ethernet
terminal. Please use the cable adapted to
10BASE-T. DUPLEX MODE is HALF DUPLEX.
RECEIVE indicator
Illuminates when the unit is receiving a signal via the
ethernet connection.
SEND indicator
Illuminates when the unit is transmitting a signal via
the ethernet connection.
16. SCSI connector
This connector is used to connect to peripheral re-
cording device (CD-R/RW, tape and HDDs).
Major operations and their functions (continued)
Rear View (continued)