- Mitsubishi Digital Electronics DVR User Manual

58
••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••
CALL OUT SETTINGS
The CALL OUT settings are used with the rear CALL OUT
terminals outputting a signal to notify of a specified condition.
CALL OUT SETTINGS use photo-coupler output to
decrease the amount of malfunctions due to writing .
See page 19 CALL OUT Output terminal for apt con-
nection procedures.
• HDD MAIN REMAIN/HDD SUB REMAIN/
ARCHIVE REMAIN
When the remaining memory in the HDD or ARCHIVE
device reaches the set value, the unit outputs a signal
from the CALL OUT terminal, and the REC/REM or
ARCHIVE/REM warning displayed on the screen.
<CALL OUT SETTINGS>
>>
HDD MAIN REMAIN OFF
HDD MAIN FULL OFF
HDD SUB REMAIN OFF
HDD SUB FULL OFF
ARCHIVE REMAIN OFF
ARCHIVE FULL OFF
HDD SUB REMAIN appears when PARTITION
is selected on HDD SETTING of the <INITIALIZA-
TION> screen.
ARCHIVE REMAIN appears when ARCHIVE
COPY is selected on ID4ID5 of the <INITIALIZA-
TION> screen.
Setting ( default : OFF )
2%, 4%, 6%, 8%, 10%, 15%, 20%, 30%,
40%, 50%, OFF
1. Press the SET UP button
}
<SETTINGS>
}
<INITIAL SET
UP/INFORMATION>
}
<REAR TERMINAL SETTINGS>
}
Select HDD MAIN REMAIN, HDD SUB REMAIN or
ARCHIVE REMAIN in the <CALL OUT SETTINGS> screen.
Display the desired setting and confirm.
2. Turn the SHUTTLE ring counterclockwise or press the SET
UP button to exit.
By pressing the WARNING RESET button, the HDD
capacity and archive capacity warning from the CALL
OUT terminal can be cancelled.
INFORMATION
For the relationship of the warning display and CALL
OUT signal output, see pages 96, 97. Although the
warning will be displayed regardless if the output item
for the CALL OUT signal is set to Fixed, the condition
to output CALL OUT signals can be added when the
output is set to Selectable. For example, the buzzer
can be set to sound when reaching a value set in HDD
MAIN REMAIN, HDD SUB REMAIN or ARCHIVE
REMAIN of the <CALL OUT SETTINGS> screen if
BUZZER in the <REAR TERMINAL SETTINGS>
screen is set to WARNING.
• HDD MAIN FULL/HDD SUB FULL/ARCHIVE FULL
When the HDD is full, the CALL OUT terminal outputs a
CALL OUT signal.
<CALL OUT SETTINGS>
HDD MAIN REMAIN OFF
>>
HDD MAIN FULL OFF
HDD SUB REMAIN OFF
HDD SUB FULL OFF
ARCHIVE REMAIN OFF
ARCHIVE FULL OFF
HDD SUB FULL appears when the HDD SET-
TING is selected on PARTITION of the <INITIALIZA-
TION> screen.
ARCHIVE FULL appears when the ID4ID5 is
selected on ARCHIVECOPY of the <INITIALIZA-
TION> screen.
Setting ( default : OFF )
ON : Signal is outputted when the recording capacity
becomes full.
OFF : No signal is outputted when the recording ca-
pacity becomes full.
1. Press the SET UP button
}
<SETTINGS>
}
<INITIAL SET
UP/INFORMATION>
}
<REAR TERMINAL SETTINGS>
}
Select HDD MAIN FULL , HDD SUB FULL or ARCHIVE
FULL in the <CALL OUT SETTINGS> screen. Display the
desired setting and confirm.
2. Turn the SHUTTLE ring counterclockwise or press the SET
UP button.
EMERGENCY REC DURATION
The recording time for emergency recording can be set.
<REAR TERMINAL SETTINGS>
MODE OUT 1 OFF
MODE OUT 2 OFF
MODE OUT 3 OFF
MODE OUT 4 OFF
MODE OUT 5 OFF
KEY SOUND ON
BUZZER OFF
REMAIN HDD MAIN-10
%
CALL OUT SETTINGS
>>
EMERGENCY REC DURATION 10M
For details concerning setting EMERGENCY RE-
CORDINGS,
see page 72.
Setting ( default : 10M )
1M, 2M, 5M, 10M, 20M, 30M, 60M
1. Press the SET UP button
}
<SETTINGS>
}
<INITIAL SET
UP/INFORMATION>
}
Select EMERGENCY REC
DURATION in the <REAR TERMINAL SETTINGS> screen.
Display the desired setting and confirm.
2. Turn the SHUTTLE ring counterclockwise or press the SET
UP button to exit.
COMMUNICATION PORT SETTINGS
<INITIAL SET UP/INFORMATION>
HDD SETTINGS
AUDIO RECORDING OFF
REAR TERMINAL SETTINGS
>>
COMMUNICATION PORT SETTINGS
CAMERA CONTROL
INFORMATION/SERVICE
PASSWORD
LANGUAGE SELECTION
<INITIAL SET UP/INFORMATION> (continued)