2006 HEAD OFFICE: TOKYO BLDG.,2-7-3, MARUNOUCHI,CHIYODA-KU, TOKYO 100-8310, JAPAN http://Global.MitsubishiElectric.com/ L-179-5-C6975-D SI 0608 New publication effective Aug.
, Mitsubishi Electric s Long history proves excellence in air conditioning with the leading-edge technology. With 50 years experience in developing air conditioner, Mitsubishi Electric's cost effective , energy conscious systems are expertly designed to provide you with constant , comfortable living and working environments.
Line-up Multi Series M series ■INVERTER Models ● Heat Pump type Model Name 2.0kW 2.2kW MSZ-FA series 2.5kW H 3.5kW 5.0kW 6.0kW 7.1kW 8.
Line-up P series P series ■POWER INVERTER Models Model Name 4 way Cassette ■FIXED-SPEED Models 3.5kW 5.0kW 6.0kW 1.6HP 2HP 2.5HP * * * ** 7.1kW 10.0kW 12.5kW 14.0kW 20.0kW 3HP 4HP 5HP 6HP 8HP ** 25.0kW Model Name 7.1kW 10.0kW 12.5kW 14.0kW 20.0kW 25.
Inverter & Energy Saving Technology Joint Lap DC Motor Highly Efficient DC Scroll Compressor ( M Series ) ( PUHZ Series ) Our unique motor, known as “Poki-Poki Motor“ in Japan, employs joint lap production technique. Originally developed by Mitsubishi Electric, this motor offers high density and high magnetic force leading to high efficiency and high reliability.
Silent Operation Technology Cleaning-Free, Pipe Reuse Technology Indoor Unit Ultra Silent Indoor Unit Operation Quiet 4 way Cassette Noise level during normal operation is only 21dB for the new MSZ-FA/GA25, making it one of the quietest indoor units in the industry. Inside the unit, the multiangled heat exchanger has a modified fin shape that reduces air resistance for a smoother, quieter airflow.
Control Technology Employment of Dot Liquid Crystal Display Acknowledging the operation and control status at a glance. The large size display upgrades visual acknowledgement capability. The operation and control status can be understood promptly.
SYSTEM CONTROLS Versatile system controls can be realized by using optional parts, relay circuits, control panels, etc. [1] For M series Indoor Units (New A-control models only) System examples 1 Connection detail Wired Remote Control • Air conditioners can be controlled by wired remote controller equipped with Weekly Timer function. [2] For P series and S series Indoor Units MAC397IF-E Wired remote controller can be connected to indoor unit via interface.
FA Series ※ The Plasma Duo goes beyond just catching the unpleasant odors, and proceeds to powerfully crush them. The all-out pursuit of real air quality. ※2.5kw class With our new moving "i see sensor", no temperature gap goes free. The moving "i see sensor" automatically moves from side to side, searching out temperature disparities over a wide area of 150° .
MFZ Series For your Living Room, or Bed Room. The latest Mitsubishi innovation – floor standing air-conditioner sophisticated in design, rich in function. Optimum Air Distribution Cleaner and Healthier Air Comfy room temperatures are realized by the optimum, powerful and efficient air distribution through upper and lower air outlets. The upper vane angle is remote controllable, with 5 air flow direction levels (+ Swing and Auto modes) and 4 wind power levels (+ Auto mode).
Power Inverter Thanks to the new Power Inverter system, a large reduction in power consumption is now possible. This results in one of the highest COP ratings in the industry, helping to lower overall running costs and providing great savings to customers. Indoor Units Higher Cooling & Heating Power Wider Performance Range The cooling & heating capacities at the maximum operating speed have also been improved by up to 33% compared to the current model.
Standard Inverter A Product Line of 31 Models in 8 Types Responds to Your Versatile Needs. Our New Inverter Features Energy Saving, Compact Design, Light Weight, and Basic Performances as well. NEW! To meet your interior or space designing, optimum indoor units can be selected from 8 types that include 4-way ceiling cassettes. A combination with different type indoor units in two or three rooms besides 1:1 combination can be constituted thus satisfying various applications.
MXZ series Our Strengthened MXZ Lineup Provides a Quiet, Highly Efficient and Flexible Air Conditioning System For All Your Air Conditioning Needs Power Multi MXZ-8A140VA EER COP A A Smaller MXZ 2, 3 and 4 ports DC Inverter Flexible Choice of Indoor unit The MXZ-2A/3A/4A can be connected to maximum of 2, 3 & 4 indoor units, optimizing use of outdoor space and enhancing exterior aesthetics. The Power Multi satisfies all your needs.
Icons Energy Saving DC Inverter DC Inverter i-see Sensor PAM Control PAM control AREA AREA setting COP EER A EER A Econo Cool A COP A I FEEL Econo Cool 'I FEEL' Control Comfort Only 21dB SWING Super Quiet : Only 21 dB Swing (vertical vane) VERTICAL High Ceiling Quiet SWING HORIZONTAL High Ceilling Air Flow Setting 72 patterns Quiet operation VERTICAL AIR FLOW AUTO VANE Vertical Air flow SWING Swing (horizontal vane) Wide Long Auto Vane Wide & Long Airflow HORIZONTAL 72 Patte
MSZ-FA series HEAT PUMP MSZ-GA series HEAT PUMP EER COP EER COP A A A Indoor Unit Outdoor Unit Outdoor Unit Remote Controller Remote Controller DC Inverter Glossy White PAM Control Econo Cool Compact AREA Only AUTO VANE 21dB Area setting FA25 ACO Auto Restart Heating at -20˚C Wall mounted Type Specifications Quick Clean Self Diagnosis Cooling at Heating at 46˚C/-10˚C -10˚C kW kW kW Total Input IN [Low-Mid-High-SHi]*1 dB(A) OUT dB(A) IN [Low-SHi]*1 m3/min Rated Min - Max
MSZ-GA/GBseries HEAT PUMP Indoor Unit MSZ-HA series HEAT PUMP Indoor Unit MSZ-GB50 Outdoor Unit Remote Controller Outdoor Unit Remote Controller MSZ-GA60/71 DC Inverter PAM Control AUTO VANE Econo Cool SWING GA60/71 Glossy White GB50 Faliure Recall ACO Auto Restart SWING HORIZONTAL Cooling at Heating at -10˚C -10˚C 24-hour Timer 15m 30m Wide Long Catechin Anti-Allergy Enzyme GA60/71 GA60/71 as Standard filter Optional GB50 Weekly Timer Optional MXZ connection Optiona
MSZ-CB series HEAT PUMP MSH-GA series HEAT PUMP EER COP EER COP A Indoor Unit A A Indoor Unit Outdoor Unit Outdoor Unit Remote Controller Remote Controller DC Inverter PAM Control Only 21dB Econo Cool AUTO VANE ACO Auto Restart SWING HORIZONTAL CB25 Cooling at Heating at 46˚C/-10˚C -10˚C 24-hour Timer 12m 20m MXZ connection Catechin Anti-Allergy Enzyme as Standard filter Optional Weekly Timer Optional Faliure Recall Optional Centralized On/Off Optional Glossy White
MSH-GA series HEAT PUMP MS-GA series Cooling Only Indoor Unit EER Indoor Unit A GA20/25 Outdoor Unit Outdoor Unit Remote Controller MUH-GA50VB AUTO VANE I FEEL Econo Cool SWING Auto Restart Self Diagnosis 24-hour Timer SWING Long Wide VERTICAL 10m 25m GA50/60 MUH-GA60/80VB as Standard filter HORIZONTAL 15m 30m Catechin Air-Cleaning Flat Panel Air Volume Heating Capacity Total Input COP SPL Air Volume Max.
MS-GA series Cooling Only MSH-CB series HEAT PUMP EER COP Indoor Unit A Indoor Unit A CB20/25/35 CB20/25/35 MSH-CB20/25/35VB Outdoor Unit Outdoor Unit MSH-CB50VB Remote Controller MU-GA50/60VB AUTO VANE I FEEL Econo Cool SWING Auto Restart Self Diagnosis 24-hour Timer SWING Long Wide VERTICAL 10m 25m GA50/60 MU-GA80VB as Standard filter HORIZONTAL 15m 30m Catechin Air-Cleaning Flat Panel Air Volume Heating Capacity Total Input COP SPL Air Volume Max.
MFZ-KA series HEAT PUMP MCFH-GA series HEAT PUMP COP EER COP Indoor Unit A A KA25/35 KA25/35 A Indoor Unit GA35 Outdoor Unit Outdoor Unit Remote Controller SUZ-KA25/35VA(H) DC Inverter PAM Control Only Econo Cool 22dB KA25 ACO i save Auto Restart 24-hour Timer Self Diagnosis AUTO VANE SWING HORIZONTAL HORIZONTAL VERTICAL AIR FLOW Cooling at Cooling at Heating at 46˚C/-10˚C -10˚C -10˚C Faliure Recall 12m 20m KA25/35 15m 30m MXZ connection KA50 Catechin Anti-Allerg
MCF-GA series Cooling Only Indoor Unit Outdoor Unit Remote Controller MUCF-GA35VB I FEEL Econo Cool AUTO VANE SWING HORIZONTAL Air-Cleaning Deodorizing Optional Optional MUCF-GA50/60VB Auto Restart Self Diagnosis 10m 25m 24-hour Timer Two-way Floor Standing and Ceiling suspended Type Specifications Type Model Name Indoor Unit Outdoor Unit Power Supply [V, Phase, Hz, Source] Cooling Capacity Rated Min - Max Total Input Rated EER SPL Air Volume Heating Capacity Total Input COP SPL Air Volume
SLZ-KA series HEAT PUMP SEZ-KC/KA series HEAT PUMP EER COP Indoor Unit A A KA25/35 KA25/35 Indoor Unit EER COP A A KC25/KA35 KC25/KA35 SEZ-KA SEZ-KC Outdoor Unit Outdoor Unit Remote Controller Remote Controller SUZ-KA25/35VA DC Inverter PAM Control AUTO VANE Long Life Fresh Air Intake 2x2 Weekly -10˚C Timer SLZ-KA VA 600 x 600 Centralized connection On/Off M-NET SLZ-KA VA Model Name Indoor Unit Outdoor Unit Power Supply [V, Phase, Hz, Source] Cooling Capacity Rated Min - Ma
PLZ-RPseries HEAT PUMP POWER INVERTER Indoor Unit Outdoor Unit PUHZ-RP35/50 Remote Controller High Ceiling 72 SWING AUTO VANE patterns 4 notch Hot Start PUHZ-RP60/71 Quiet PUHZ-RP100/125/140 Lossnay connection Fresh Air Intake High efficiency Weekly Timer Group Control M-NET connection ACO COMPO Handy Drain Lift UP 75m Gas Volume Check *RP100∼140 P series Heating at -20˚C Auto Restart Easy Maintenance *RP100∼140 Optional corner pocket IN/OUT Power Supply Anti mold DP S
PEDZ-RP EA series HEAT PUMP PEDZ-RP GA series POWER INVERTER POWER INVERTER Indoor Unit Indoor Unit Outdoor Unit Outdoor Unit Remote Controller Remote Controller PUHZ-RP35/50 Hot Start Weekly Lossnay Quiet connection Check! Auto Restart Timer PUHZ-RP60/71 Group Control M-NET connection 75m Self Diagnosis Easy Maintenance IN/OUT Power Supply Exising Wiring Reuse *Optional Optional *RP100∼140 ACO COMPO Heating at Indoor Unit Outdoor Unit PEAD-RP35EA2 PUHZ-RP35VHA2 Power Supp
PEZ-RP series HEAT PUMP PKZ-RPseries HEAT PUMP POWER INVERTER POWER INVERTER Indoor Unit Indoor Unit PKA-RP GAL Outdoor Unit Outdoor Unit Remote Controller PKA-RP FAL Remote Controller PUHZ-RP35/50 PUHZ-RP200/250 Hot Start Lossnay connection Check! Group Control M-NET connection Heating at ACO -20˚C Auto Restart Optional IN/OUT Power Supply Exising Wiring Reuse Optional Optional 120m Self Diagnosis Heating Capacity Total Input COP Indoor Dimensions EEL Rank Height Width Depth
PCZ-RP GA series HEAT PUMP PCZ-RP HA series HEAT PUMP for Professional Kitchen use POWER INVERTER POWER INVERTER Indoor Unit Indoor Unit Outdoor Unit Outdoor Unit Remote Controller Remote Controller PUHZ-RP50 PUHZ-RP60/71 PUHZ-RP100/125/140 PUHZ-RP71 *optional SWING 4 notch AUTO VANE Hot Start Check! Timer ACO Group Control Easy Maintenance IN/OUT Power Supply Exising Wiring Reuse Gas Volume Check Optional Optional Weekly Lossnay Quiet connection High efficiency SWING AUTO
PSZ-RPseries HEAT PUMP POWER INVERTER SPLZ-Pseries PLZ-Pseries Indoor Unit HEAT PUMP STANDARD INVERTER Indoor Unit Outdoor Unit Outdoor Unit PUHZ-RP71 Built-in Controller Hot Start Long Life Group Control Lossnay Weekly Check! connection Timer M-NET connection ACO PUHZ-RP100/125/140 COMPO Optional Self Diagnosis 75m Easy Maintenance IN/OUT Power Supply Exising Wiring Reuse Optional Optional *RP100∼140 High Ceiling Heating at -20˚C Indoor Unit Outdoor Unit PSA-RP71GA PUHZ-RP
SPEDZ-P EA series PEDZ-P EA series HEAT PUMP SPEDZ-P GAseries PEDZ-P GA series STANDARD INVERTER HEAT PUMP STANDARD INVERTER Indoor Unit Indoor Unit Outdoor Unit Outdoor Unit Remote Controller Remote Controller SUZ-KA35 SUZ-KA50/60/71 PUHZ-P100 PUHZ-P125/140 SUZ-KA50/60/71 Hot Start Weekly Lossnay Quiet connection Timer Check! Group Control M-NET connection Easy Maintenance PUHZ COMPO ACO Auto Restart Power Supply Easy Maintenance IN/OUT Power Supply *Optional PUHZ Optional S
PKZ-Pseries HEAT PUMP STANDARD INVERTER Indoor Unit SPCZ-P GA series PCZ-P GA series HEAT PUMP STANDARD INVERTER Indoor Unit PKA-RP FAL Outdoor Unit Outdoor Unit Remote Controller Remote Controller PUHZ-P100 SUZ-KA50/60/71 SWING *optional SWING AUTO VANE 4 notch Hot Start Lossnay Quiet connection Weekly Timer Group Control M-NET connection *optional ACO Auto Restart Self Diagnosis Drain Lift UP IN/OUT Power Supply Optional Optional COMPO Weekly COMPO Timer Inverter Heat Pum
PCZ-P HA series HEAT PUMP for Professional Kitchen use PSZ-Pseries HEAT PUMP STANDARD INVERTER STANDARD INVERTER Indoor Unit Indoor Unit Outdoor Unit Outdoor Unit Remote Controller PUHZ-P125 SWING AUTO VANE Hot Start Lossnay Quiet OIL Mist Fresh Air Intake Check! connection Weekly Timer Group Control PUHZ-P100 Built-in Controller M-NET connection Hot Start Lossnay connection Long Life Check! Group Control ACO COMPO Auto Restart IN/OUT Power Supply IN/OUT Power Supply Self
PLH-Pseries HEAT PUMP PL-Pseries FIXED SPEED Cooling Only FIXED SPEED Indoor Unit Indoor Unit Outdoor Unit Outdoor Unit Remote Controller PUH-P71/100 High Ceiling 72 SWING patterns AUTO VANE 4 notch Hot Start PUH-P125/140 Lossnay Quiet connection Fresh Air Intake Timer Group Control High Ceiling Check! Optional Air flow Weekly High efficiency PU-P71/100 Remote Controller M-NET connection ACO Auto Restart COMPO Handy corner pocket Drain Lift UP Self Diagnosis Anti mold
PEHD-P EA series HEAT PUMP PED-P EA series FIXED SPEED Cooling Only FIXED SPEED Indoor Unit Indoor Unit Outdoor Unit Outdoor Unit Remote Controller Remote Controller PUH-P71/100 Hot Start Quiet Lossnay connection Check! Group Control M-NET connection PUH-P125/140 Weekly Timer ACO Auto Restart COMPO PU-P71/100 Self Diagnosis Quiet Lossnay connection Check! Optional Group Control Weekly M-NET connection Timer PU-P125/140 Auto Restart COMPO Self Diagnosis Optional Booster He
PEHD-P GA series HEAT PUMP PED-P GA series FIXED SPEED Cooling Only FIXED SPEED Indoor Unit Indoor Unit Outdoor Unit Outdoor Unit Remote Controller Remote Controller PU-P71/100 PUH-P71/100 Hot Start Quiet Weekly Lossnay Fresh Air Intake connection Check! Timer Group Control M-NET connection ACO Auto Restart COMPO Quiet Lossnay connection Fresh Air Intake Check! Group Control M-NET connection Auto Restart Weekly COMPO Timer Self Diagnosis Optional Optional Self Diagnosis
PKH-Pseries HEAT PUMP PK-Pseries FIXED SPEED Cooling Only FIXED SPEED Indoor Units Indoor Unit PKA-RP FAL PKA-RP FAL Outdoor Unit Outdoor Unit Remote Controller Remote Controller PU-P71/100 PUH-P71/100 SWING *optional AUTO VANE 4 notch Hot Start Quiet Lossnay connection Weekly Timer Group Control M-NET connection SWING ACO *optional Auto Restart AUTO VANE 4 notch Quiet Lossnay Weekly connection Timer Group Control M-NET connection Optional COMPO Self Diagnosis Drain Li
PCH-P GA series HEAT PUMP PC-P GA series FIXED SPEED Cooling Only FIXED SPEED Indoor Unit Indoor Unit Outdoor Unit Outdoor Unit Remote Controller Remote Controller PUH-P71/100 PUH-P125/140 PU-P71/100 PU-P125/140 *optional SWING AUTO VANE 4 notch Hot Start Quiet Lossnay connection High efficiency Check! Weekly Timer Group Control Optional *optional ACO Auto Restart COMPO Drain Lift UP Self Diagnosis SWING M-NET connection Self Diagnosis Power Supply [V, Phase, Hz] Heating
PCH-P HA series HEAT PUMP for Professional Kitchen use PC-P HA series Cooling Only for Professional Kitchen use FIXED SPEED FIXED SPEED Indoor Unit Indoor Unit Outdoor Unit Outdoor Unit Remote Controller Remote Controller PUH-P71 SWING AUTO VANE Hot Start Quiet Weekly Lossnay connection OIL Mist Check! Timer PUH-P125 Group Control M-NET connection PU-P71 SWING ACO AUTO VANE Quiet Lossnay connection OIL Mist Check! Weekly Timer COMPO Power Supply [Source, V, Phase, Hz] Cool
PSH-Pseries HEAT PUMP PS-Pseries FIXED SPEED Cooling Only FIXED SPEED Indoor Unit Indoor Unit Outdoor Unit Outdoor Unit PUH-P71/100 PUH-P125/140 Built-in Controller PU-P71/100 Built-in Controller Hot Start Weekly Lossnay connection Long Life Check! Auto Restart Timer Group Control M-NET connection ACO COMPO Lossnay Self Diagnosis connection Long Life Check! Group Control Weekly M-NET connection Timer PU-P125/140 Auto Restart COMPO Self Diagnosis Optional Optional Boost
PEH series HEAT PUMP FIXED SPEED Indoor Unit Outdoor Unit Remote Controller PUH-P200/250 Hot Start Weekly Lossnay connection Check! Timer Group Control M-NET connection ACO Auto Restart Self Diagnosis Optional Ceiling Concealed Type Specifications Type Non-Inverter Heat Pump Indoor Unit Outdoor Unit Power Supply [V, Phase, Hz] Cooling Capacity Total Input EER Heating Capacity Total Input COP Indoor Dimensions kW kW EEL Rank Rated Rated kW kW Weight Air Volume External Static Pressur
MXZ-8A140VA MXZ-8A140VA Specifications A Variety of Indoor Units Consisting of 28 Models in 10 Types Allows Your Best Selection. Wall Mounted Type Inverter Multi-Split -up to 8 indoor units MXZ-8A140VA Model Name (Outdoor unit ) Ceiling Cassette Power Supply [V, Phase, Hz, Source] Cooling Capacity Rated Power Input *1 EER *2 220 / 230 / 240 , single, 50, outdoor Power Supply kW 14.0 kW 3.79 3.
MXZ-A series HEAT PUMP Combination table MXZ-4A80VA Connectable indoor units Outdoor Units 4-port MSZ-FA25/35 SLZ-KA25/35/50 PLA-RP50/60/71 MSZ-GA22/25/35 MXZ-4A80VA 3-port/4-port SEZ-KA35/50/60 SEZ-KC25 MSZ-GB50VA MSZ-GA60/71 MXZ-3A54VA MXZ-4A71VA PEAD-RP50EA PEAD-RP60/71GA 2-port MFZ-KA25/35/50 PCA-RP50/60/71 MXZ-3A54VA:Indoor units of up to 5.0kw size can be connected. MXZ-4A71VA:Indoor units of up to 6.0kw size can be connected.
NOTE: Electrical data is for outdoor unit only. NOTE: Electrical data is for outdoor unit only. 79 Current (A) Power factor (%) Indoor units combination Unit A Unit B Unit C Unit D Total Outdoor unit power consumption (kW) Current (A) Power factor (%) Indoor units combination Unit A Unit B Unit C Unit D Total Outdoor unit power consumption (kW) 35 + 50 + 50 2.08 2.96 2.96 – 8.0 (2.9 - 9.0) 2.240 (0.680 - 2.840) 9.84 99 22 3.3 – – – 3.3 (1.2 - 4.2) 1.050 (0.340 - 1.
Combination table NOTE: Electrical data is for outdoor unit only. 81 MXZ-4A71VA NOTE: Electrical data is for outdoor unit only. Total Outdoor unit power consumption (kW) Current (A) Power factor (%) 2.2 2.2 (1.4 - 3.0) 0.590 (0.420 - 0.740) 2.59 99 2.5 2.5 (1.4 - 3.3) 0.660 (0.420 - 0.830) 2.90 99 35 3.5 3.5 (1.5 - 4.3) 0.950 (0.430 - 1.180) 4.17 99 99 50 5.0 5.0 (1.6 - 5.6) 1.500 (0.480 - 1.660) 6.59 99 8.61 99 60 6.0 6.0 (1.6 - 6.0) 2.110 (0.480 - 2.290) 9.27 99 1.
Combination table NOTE: Electrical data is for outdoor unit only. 83 MXZ-3A54VA NOTE: Electrical data is for outdoor unit only. Total Outdoor unit power consumption (kW) Current (A) Power factor (%) 2.2 2.2 (1.4 - 3.0) 0.590 (0.420 - 0.740) 2.59 99 2.5 2.5 (1.4 - 3.3) 0.660 (0.420 - 0.830) 2.90 99 35 3.5 3.5 (1.5 - 4.3) 0.950 (0.430 - 1.180) 4.17 99 99 50 5.0 5.0 (1.6 - 5.6) 1.500 (0.480 - 1.660) 6.59 99 9.44 99 22 + 22 2.2 2.2 4.4 (2.0 - 5.4) 1.180 (0.540 - 1.450) 5.
Combination table NOTE: Electrical data is for outdoor unit only. MXZ-2A52VA NOTE: Electrical data is for outdoor unit only. Total Outdoor unit power consumption (kW) Current (A) Power factor (%) 2.20 2.2 (0.9 - 3.0) 0.430 (0.120 - 0.620) 2.08 90 2.50 2.5 (0.9 - 3.3) 0.490 (0.120 - 0.690) 2.37 90 35 3.50 3.5 (0.9 - 4.0) 0.730 (0.120 - 0.900) 3.53 90 99 22 + 22 2.20 2.20 4.4 (1.1 - 5.3) 1.130 (0.250 - 1.510) 5.12 96 6.59 99 22 + 25 2.20 2.50 4.7 (1.1 - 5.4) 1.250 (0.
MSX series Multi-Split System MUX-2A28VB 1 OUT DOOR UNIT MSX Specifications Type Model Name 2 INDOOR UNITS for 2 MSC-GA20 Indoor Unit Fixed-Speed Multi Split Cooling Only - up to 2 indoor units MSX-2A70VB MSX-2A28VB MSX-2A59VB (A , B) MSC - GA35VB (A , B) MSC - GA20VB (A) MSC - GA35VB / (B) MSC - GA20VB Outdoor Unit (A + B) (A or B) MUX-2A28VB Power Supply [V, Phase, Hz, Source] Cooling Capacity Individual rooms Power Input EER MSC-GA20 Total Rated EEL Rank SPL [Outdoor] Silent Air Volume [Ou
Mr.SLIM Multi - System Multiple (2,3 & 4) indoor units can be operated simultaneously with a single outdoor unit. Twin Procedure of selection allows the simultaneous operation of 2 indoor units on one floor. Quadruple can realize the optimum temperature distribution even in a large space. Selection of Outdoor unit Selection of Indoor unit Selection of Distribution Pipe Please choose an outdoor unit with capacity to cover the size (air conditioning load) of the installation space.
Accessories Conditions for specifications Model Name MSDD-50SR-E MSDD-50WR-E MSDD-50AR-E MSDD-50BR-E MSDT-111R-E SDT-112SA-E SDT-122SA-E MSDF-1111R-E PAC-SG72RJ-E PAC-SG73RJ-E PAC-SG74RJ-E PAC-SG75RJ-E PAC-SG76RJ-E PAC-493PI MAC-A454JP-E MAC-A455JP-E MAC-A456JP-E PAC-SG81DR-E PAC-SG82DR-E PAC-SG85DR-E PAC-AK350CVR-E MAC-888SG PAC-SF08SG-E PAC-SG58SG-E Description Distribution Pipe Distribution Pipe (to connect 2 branch boxes): flare connection type Distribution Pipe (to connect 2 branch boxes): brazing t
Memorandum 93 Memorandum 94