User's Manual

15 - 2
15. ABSOLUTE POSITION DETECTION SYSTEM
15.2 Specifications
(1) Specification list
Item Description
System Electronic battery backup system
Battery
1 piece of lithium battery ( primary battery, nominal
3.6V)
Type: MR-BAT or A6BAT
Maximum revolution range Home position 32767 rev.
(Note 1) Maximum speed at power failure 500r/min
(Note 2) Battery backup time Approx. 10,000 hours (battery life with power off)
(Note 3) Data holding time during battery
replacement
2 hours at delivery, 1 hour in 5 years after delivery
Battery storage period 5 years from date of manufacture
Note 1. Maximum speed available when the shaft is rotated by external force at the time of power failure or the like.
2. Time to hold data by a battery with power off. It is recommended to replace the battery in three years independently of whether
power is kept on or off.
3. Period during which data can be held by the super capacitor in the encoder after power-off, with the battery voltage low or the
battery removed, or during which data can be held with the encoder cable disconnected.
Battery replacement should be finished within this period.
(2) Configuration
Positioning module I/O module
A1SD71S2 A1SD71S7
A1SD75
AX40 41 42
AY40
41 42
FX2N-1GP FX2N-10PG FX2N-10GM
FX2N-20GM
FX
2N(C) series, FX3U(C) series
CN1A
CN1B
CON1
Servo motor
CN2
A1SD75 etc.
I/O
Programmable controller Servo amplifier
Battery (MR-BAT)
(3) Parameter setting
Set " 1 " in parameter No.1 to make the absolute position detection system valid.
1
Selection of absolute position detection system
0: Incremental system
1: Absolute position detection system
Parameter No. 1