Programming Manual

APP - 46
A
PPENDICES
Table 2.2 Special register list (continued)
No. Name Meaning Details
Set by
(When set)
Remark
D9026
Clock data
(Day, hour)
• Stores the day and hour in BCD.
B15 B12to B11 B8to B7 B4to B3 B0to
Day Hour
Example : 31st, 10 a.m.
H3110
D9027
Clock data
Clock data
(Minute, second)
• Stores the minute and second in BCD.
Example : 35 min., 48 sec.
H3548
B15 B12to B11 B8to B7 B4to B3 B0to
Minute
Second
D9028 Clock data
Clock data
(Day of week)
• Stores the day of the week in BCD.
B15 B12to B11 B8to B7 B4to B3 B0to
"0" must be set here.
Day of week
0
1
2
3
4
5
6
Sunday
Monday
Tuesday
Wednesday
Thursday
Friday
Saturday
Example :
Friday
H0005
S/U(Request)
D9060 Error reset
Error No. of
releasing an error
• Error No. of canceling error is stored. U
D9061 Multiple CPU No. Multiple CPU No. • CPU No. of the self CPU is stored. S(Initial processing)
• When the servo amplifier or SSCNET cable of SSCNET system are
exchanged or re-connected, an user side requires connect/disconnect, and a
system side stores the states of command accept waiting or execute waiting
for connect/disconnect.
0 : Connect/disconnect command accept waiting
-1 : Connect/disconnect execute waiting
S (Main processing)
1 to 32 : Disconnect command
-10 : Re-connect command
D9112
Connect/
disconnect
Connect/
disconnect of
SSCNET
-2 : Connect/disconnect execute command
U
D9182
D9183
Test mode
request error
It is operating in
requirement error
occurrence of the
test mode, axis
information
• Each axis is stopping: 0/Operating: 1, information is stored as a bit data.
D9182: b0 to b15 (Axis 1 to Axis 16)
D9183: b0 to b15 (Axis 17 to Axis 32)
D9184
Motion CPU
WDT error cause
Error meaning of
WDT error occurs
The following error codes are stored in D9184.
1: S/W fault 1
2: Operation cycle over
3: Q bus WDT error
4: WDT error
30: Information processor H/W error
201 to 215: Q bus H/W fault
250 to 253: Servo amplifier interface H/W fault
300: S/W fault3
301: 15 CPSTART instructions of 8 or more points were started
simultaneously.
D9185
D9186
D9187
Manual pulse
generator axis
setting error
Manual pulse
generator axis
setting error
information
Contents of the manual pulse generator axis setting error is stored when the
manual pulse generator axis setting error flag (M9077) turn on.
(Normal: 0/Setting error: 1)
D9185: The manual pulse generator axis setting error is stored in b0 to b2
(P1 to P3).
The smoothing magnification setting is stored in b3 to b5 (P1 to P3).
D9186: One pulse input magnification setting error is stored in b0 to b15
(axis 1 to axis 16).
D9187: One pulse input magnification setting error is stored in b0 to b15
(axis 17 to axis 32).
S(Occur an error)