Specifications

-
9
-
Item
Model
SCM80ZG-S
Cooling capacity W 8000 (1800~9500)
Heating capacity W 9300 (800~9600)
Power source 1 Phase 220/230/240V 50Hz
Power consumption
Cooling
W
2220 (310~3000)
Heating 2430 (210~3430)
Running current
Cooling 10.2/9.7/9.3
Heating
A
11.2/10.7/10.2
Sound level
Cooling : 51 Heating : 52
Noise level
Power level
dB
Cooling : 65 Heating : 66
Exterior dimensions
Height × Width × Depth
mm 750 × 880 × 340
Color Stucco white
Net weight kg 66
Refrigerant equipment
Compressor type & Q’ty
[Twin rotary] × 1
Motor kW 1.3
Starting method Direct start
Refrigerant control Capillary tubes + Electronic expansion valve
Refrigerant kg R410A 3.15 (Pre-charged up to the piping length of 40m)
Refrigerant oil R 0.67 (MEL56)
Air handling equipment
Fan type & Q’ty
Propeller fan × 1
Motor W 86
Air flow (at high) CMM 55
Shock & vibration absorber Rubber (for compressor)
Safety equipment
Size × Core × Number mm (in)
Liquid line: φ 6.35 (1/4) × 4
Gas line: φ 9.52 (3/8) × 4
Connecting method Flare connecting
Attached length piping
Insulation Necessary (Both Liquid & Gas lines)
Power source supply Terminal block (Screw fixing type)
Size × Core number 1.5 mm
2
× 4 cores (Including earth cable) × 4
Connecting method Terminal block (Screw fixing type)
Accessories (included)
Union : (φ 9.52 / φ 12.7) × 2
Installation sheet, Manual instruction
SKM20, 22, 25, 28, 35, 50, 60, 71 type
Indoor unit to be combined STM25, 35, 50, 60 type
SRRM25, 35, 50, 60 type
Compressor overheat protection, Overcurrent protection
Serial signal error protection
Refrigerant
piping
Connection
wiring
Model SCM80ZG-S
Notes (1) The data are measured at the following conditions.
Item Indoor air temperature Outdoor air temperature
Standards
Operation DB WB DB WB
Cooling 27°C 19°C 35°C 24°C ISO-T1, JIS C9612
Heating 20°C 7°C 6°C ISO-T1, JIS C9612
(2) The values for capacity and power consumption shown in a range ( ) indicate the minimum and maximum of the range.
(3) If the piping length exceeds 40 m, additional charging is required. (20g/m)