Specifications

-
122
-
Indoor unit
(Flat surface drawing)
215 310 215 125
230
97 455
570
310130 130 97
Round duct connection port
95 95
190
ø 150
(3) Duct joint for air outlet plate
(a) Part No.: RFJ22
This duct joint is to be used for the connection of a round duct (ø 150 mm) to an indoor unit.
(b) Part list
(d) Installation procedure
Use the tapping screws to mount the duct joint to
the front of the indoor unit. Use care to prevent
gaps from forming at the joining surfaces with
the indoor unit. Use insulation at the connecting
areas between a round duct and the duct joint to
prevent condensation.
(c) Installation
Name Qty.
1
8
60
Duct joint
Tapping screws
Heat insulation materials (15
x
15
x
t3)
Duct joint
Tapping screws
(8 locations)
Indoor unit
Unit: mm
(2) Rear inlet filter set
(a) Part No.: RBF12
(b) Installation
Do not use this filter set alone.
There are two inlet ports: lower inlet port (normal) and rear inlet port.
1) Detach the rear panel and the hanger metal screwad onto the rear
panel from an indoor unit.
2) Attach the removed hanger metal to the frame of the filter set with small panhead
screws. (One screw each on the right and left sides of the frame is designed to fasten them together onto the main unit).
3) Attach the filter set onto the point where the rear panel was attached with tapping screws. (The rear panel will become of
no use anymore)
Hanger metal
Bracket for filter fixing
Tappping screw
Indoor unit
Pan-head screw