Specifications
-
26
-
2.2 Range of usage & limitations
Indoor intake air temperature
(Upper, lower limits)
Indoor units
that can be
used in
combination
Length for one indoor unit
Total length for all rooms
Max. 25m
2 to 3 units ※3 to 4 units1 to 2 units
Max. 40mMax. 30m
SCM48ZG-S SCM60ZG-S SCM80ZG-SSCM45ZG-SSCM40ZG-S
18 to 32°C
15 to 30°C
-15 to 43°C
-15 to 24°C
8.5kW 11.0kW 13.5kW
Max. 70m
7.0kW5.7kW
Compressor
stop/start
frequency
Power source
voltage
1 cycle time
Stop time
Voltage fluctuation
Voltage drop during start
Interval unbalance
Difference in height between indoor units (C)
Within ±3% of rated voltage
Within ±15% of rated voltage
Within ±10% of rated voltage
3 min or more
6 min or more (from stop to stop or from start to start)
Max. 25m
15m
15m 20m
20m
Outdoor air temperature
(Upper, lower limits)
Number of connected units
Cooling
Heating
Cooling
Heating
Total of indoor Units (class kW)
Difference in
height between
indoor and outdoor
units
When indoor unit is above
outdoor unit (A)
When indoor unit is below
outdoor unit (B)
Item
Models
※ Only combination of SKM60 + SKM60 and SKM60 + SKM71 (2 indoor units) to SCM80ZG-S can be abailable.
A
B
C