Specifications

-
46
-
S SRRM model
4.2 Unit ON/OFF button
When the remote control batteries become weak, or if the remote control is lost or malfunctioning, this button may be used to turn the
unit on and off.
(1) Operation
Push the button once to place the unit in the automatic mode. Push it once more to turn the unit off.
(2) Details of operation
The unit will go into the automatic mode in which it automatically determines, from room temperature (as detected by sensor),
whether to go into the cooling, thermal dry or heating modes.
Unit ON/OFF button
S SKM20~50 model
S STM model
Flap
(SKM, STM only)
Function
Operation mode
Cooling
Thermal dry
Heating
Room temperature setting
SKM 20 ~ 50 SKM 60 · 71 STM, SRRM
About 24°C About 24°C About 24°C
About 24°C About 24°C About 24°C
About 26°C About 26°C About 26°C
Fan speed
Auto
Timer switch
Continuous
Auto
S SKM60·71 model
Unit ON/OFF button