Specifications
-
48
-
4.5 Custom cord switching procedure
If two wireless remote controls are installed in one room, in order to prevent wrong operation due to mixed signals, please modify the
printed circuit board in the indoor unit’s control box and the remote control using the following procedure. Be sure to modify both
boards. If only one board is modified, receiving (and operation) cannot be done.
(1) Modifying the indoor unit’s printed circuit board
Take out the printed circuit board from the control box and cut off jumper wire (SKM20~50 model: J13 SKM60·71, STM, SRRM
model: J4) using wire cutters.
After cutting of the jumper wire, take measures to prevent contact with the other the lead wires, etc.
EXTERNAL INPUT
WIRED REMOCON
OPE PERMISSION
CUSTOM
AUTO RESTART
LO TEMP
DIRT PREVENT
COOL ONLY
HI CEIL
PANEL
50/60
S SKM20~50 model S SKM60·71, STM, SRRM model
4.6 Determining the operating mode
The cooling and heating operating modes are the remote control switch mode that have been previously determined.
If a mode differing from these is selected after this, the selected mode will appear in the display of the remote control, but only the fan
will operate.
A unit
B unit
Cooling
Cooling
Fan Heating
HeatingFan
Cooling
switch
ON
Heating
switch
ON
Heating
switch
ON
Cooling
switch
ON
Heating
switch
ON
Operation Operation
Operation Operation
Operation
Example of operating pattern
Note (1) [ ] indicates currect operation.
First operation Second operation
Notes
Selected Mode
Cooling
Heating
Example
1
2
Remote Control Display
Cooling
Heating
Operation
Cooling
Heating
Selected Mode
Heating
Cooling
Remote Control Display
Heating
Cooling
• Different mode is
only fan operation.
Operation
Fan
(1)
Fan
Note (1) If the display shows heat-
ing and the operation is
fan, Hot Keep will oper-
ate.
(2) Modifying the wireless remote control
(a) Remove the battery.
(b) Cut the jumper wire shown in the figure at right.
Cut
Jumper wire (J13)
Jumper wire (J4)