Specifications
-
73
-
4) Installing the support of piping
[Matters of special notice when piping from left or center/rear of the unit.]
Piping
Drain hose
¡ Tape only the portion that goes through the wall.
Always tape the crossover wiring with the piping.
¡ Hold the bottom of the piping and fix direction before
stretching it and shaping it.
[Top View]
[Shaping the piping] [Taping of the exterior]
Left-hand-sided-piping
Piping in the left rear direction
Piping in the right rear direction
Piping in the left direction
Piping in the right direction
Right-hand-sided-piping
[Drain hose changing procedures]
1. Remove the drain hose.
¡Remove the drain hose,
making it rotate.
Since this air conditioner has been designed to collect dew drops
on the rear surface to the drain pan, do not attach the power
cord above the gutter.
Gutter
Pipe accommodation section
Drainage
¡ Arrange the drain hose in a downward angle.
¡ Avoid the following drain piping.
Higher than specified The drain hose
tip is in water.
Weavy The gap to the ground
is 5 cm or less.
The drain hose tip is in
the gutter.
Odor from
the gurtter
¡ Pour water to the drain pan located under the heat exchanger, and ensure that the water is discharged outdoor.
¡ When the extended drain hose is indoor, always use a shield pipe (to be arranged by the user) and ensure it is thermally
insulated.
Shield pipe
Extended drain hose
When it is exposed indoor.Drain hose
¡Remove it with hand or
pliers.
¡Insert the drain cap which was removed at
procedure “2” securely using a hexagonal
wrench, etc.
Note: Be careful that if it is not inserted
securely, water leakage may occur.
¡Insert the drain hose
securely, makingit rotate.
Note: Be careful that if it is
not inserted securely, water
leakage may occur.
2. Remove the drain cap. 3. Insert the drain cap. 4. Connect the drain hose.
Piping is possible in the rear,
left, left lear, left downward,
right or downward direction.
Left
Left rear
Left downward
Downward
Rear
Right