Installation manual

2
1. Safety precautions
Contents
1. Safety precautions ............................................................................................. 2
2. Installation location ............................................................................................
3
3. Installing the outdoor unit ..................................................................................
4
4. Installing the refrigerant piping ..........................................................................
5
5. Drainage piping work .........................................................................................
8
6. Electrical work ...................................................................................................
8
7. Test run ............................................................................................................
10
8. Special Functions .............................................................................................
11
9. System control .................................................................................................
12
►Beforeinstallingthe unit,make sure you read allthe “Safety
precautions”.
►Pleasereporttoortakeconsentbythesupplyauthoritybefore
connectiontothesystem.
►“This equipment complies with IEC 61000-3-12 provided that
theshort-circuitpowerS
SC
isgreaterthanorequaltoS
SC
(*1)
attheinterfacepointbetweentheuser’ssupplyandthepublic
system. It isthe responsibility of the installer oruser of the
equipmenttoensure,byconsultationwiththedistributionnet-
work operator if necessary, that the equipment is connected
onlytoasupplywithashort-circuitpowerS
SC
greaterthanor
equaltoS
SC
(*1)”
S
SC
(*1)
Model S
SC
(MVA)
PUHZ-RP200YHA2 1.35
PUHZ-RP250YHA2 1.49
Warning:
Describesprecautionsthatmustbeobservedtopreventdangerofinjuryor
deathtotheuser.
Caution:
Describesprecautionsthatmustbeobservedtopreventdamagetotheunit.
After installation work has been completed, explain the “Safety Precautions,” use,
and maintenance of the unit to the customer according to the information in the
Operation Manual and perform the test run to ensure normal operation. Both the
Installation Manual and Operation Manual must be given to the user for keeping.
These manuals must be passed on to subsequent users.
: Indicates a part which must be grounded.
Warning:
Carefullyreadthelabelsafxedtothemainunit.
Warning:
Theunit mustnotbeinstalled bytheuser.Ask adealeroran authorized
techniciantoinstalltheunit.Iftheunitisinstalledincorrectly,waterleak
-
age,electricshock,orremayresult.
Forinstallationwork,followtheinstructionsintheInstallationManualand
usetools and pipe components specicallymade foruse with R410A re
-
frigerant.TheR410ArefrigerantintheHFCsystemispressurized1.6times
the pressure of usual refrigerants. Ifpipe components not designedfor
R410Arefrigerantareusedandtheunitisnotinstalledcorrectly,thepipes
mayburstandcausedamageorinjuries.Inaddition,waterleakage,electric
shock,orremayresult.
Theunitmustbeinstalled according to the instructions in order tomini-
mizetheriskofdamagefromearthquakes,typhoons,orstrongwinds.An
incorrectlyinstalledunitmayfalldownandcausedamageorinjuries.
The unit must be securely installed on a structure that can sustain its
weight.Iftheunitismountedonanunstablestructure,itmayfalldownand
causedamageorinjuries.
Iftheairconditionerisinstalledinasmallroom,measuresmustbetaken
to prevent the refrigerant concentration inthe room from exceeding the
safetylimitintheeventofrefrigerantleakage.Consultadealerregarding
theappropriatemeasurestopreventtheallowableconcentrationfrombe
-
ingexceeded.Shouldtherefrigerantleakandcausetheconcentrationlimit
tobeexceeded,hazardsduetolackofoxygenintheroommayresult.
Ventilatetheroomifrefrigerantleaksduringoperation.Ifrefrigerantcomes
intocontactwithaame,poisonousgaseswillbereleased.
Allelectricworkmustbeperformedbyaqualiedtechnicianaccordingto
localregulationsandtheinstructionsgiveninthismanual.Theunitsmust
bepowered by dedicated powerlines andthe correctvoltage andcircuit
breakersmustbeused.Powerlineswithinsufcientcapacityorincorrect
electricalworkmayresultinelectricshockorre.
Use C1220copper phosphorus, for copper and copper alloy seamless
pipes,toconnecttherefrigerantpipes.Ifthepipesarenotconnectedcor
-
rectly,theunitwillnotbeproperlygroundedandelectricshockmayresult.
Useonly specied cables forwiring. The connections must bemade se-
curelywithouttensionontheterminals.Ifthecablesareconnectedorin
-
stalledincorrectly,overheatingorremayresult.
Theterminalblockcoverpaneloftheoutdoorunitmustbermlyattached.
Ifthecoverpanelismountedincorrectlyanddustandmoistureenterthe
unit,electricshockorremayresult.
Wheninstallingormovingtheairconditioner,useonlythespeciedrefrig-
erant(R410A)tochargetherefrigerantlines.Donotmixitwithanyother
refrigerantanddonotallowairtoremaininthelines.Airenclosedinthe
linescancausepressurepeaksresultinginaruptureandotherhazards.
Use only accessories authorized by Mitsubishi Electricand aska dealer
or an authorizedtechnician to installthem. If accessories are incorrectly
installed,waterleakage,electricshock,orremayresult.
Donotalterthe unit.Consultadealerfor repairs.Ifalterationsorrepairs
arenot performedcorrectly, waterleakage,electricshock, orremayre
-
sult.
Theuser should never attemptto repairthe unitor transferit toanother
location. Iftheunit isinstalled incorrectly, water leakage, electricshock,
orremayresult.Iftheairconditionermustberepairedormoved,aska
dealeroranauthorizedtechnician.
Afterinstallationhasbeencompleted,checkforrefrigerantleaks.Ifrefrig-
erantleaksintotheroomandcomesintocontactwiththeameofaheater
orportablecookingrange,poisonousgaseswillbereleased.
1.1.Beforeinstallation
Caution:
Do not use the unit inan unusual environment. If the air conditioner is
installedinareasexposedtosteam,volatileoil(includingmachineoil),or
sulfuric gas, areas exposed to high saltcontent such as the seaside, or
areaswheretheunitwillbecoveredbysnow,theperformancecanbesig
-
nicantlyreducedandtheinternalpartscanbedamaged.
Do not install the unit where combustible gases may leak, be produced,
ow,oraccumulate.If combustible gas accumulatesaroundtheunit,re
orexplosionmayresult.
The outdoor unit produces condensation during theheating operation.
Makesuretoprovidedrainagearoundtheoutdoorunitifsuchcondensa
-
tionislikelytocausedamage.
When installing the unit ina hospital or communications office, be pre-
pared for noise and electronic interference. Inverters,home appliances,
high-frequencymedicalequipment,and radiocommunicationsequipment
can cause the airconditioner tomalfunction orbreakdown. The aircon
-
ditionermay also affect medicalequipment, disturbingmedical care, and
communicationsequipment,harmingthescreendisplayquality.
1.2.Beforeinstallation(relocation)
Caution:
Be extremely careful when transporting the units. Two or more persons
are needed tohandle the unit,asit weighs 20 kg ormore. Do notgrasp
thepackagingbands.Wearprotectiveglovestoremovetheunitfromthe
packagingandtomoveit,asyoucaninjureyourhandsonthensorother
parts.
Besuretosafelydisposeofthepackagingmaterials.Packagingmaterials,
suchasnailsand othermetalorwoodenparts maycausestabs orother
injuries.
Thebaseandattachmentsoftheoutdoorunitmustbeperiodicallychecked
forlooseness,cracksorotherdamage.Ifsuchdefectsareleftuncorrected,
theunitmayfalldownandcausedamageorinjuries.
Donotcleantheairconditionerunitwithwater.Electricshockmayresult.
Tightenallare nuts tospecication using atorque wrench.If tightened
toomuch,thearenutcanbreakafteranextendedperiodandrefrigerant
canleakout.
BG79U791K01_en.indd 2 9/18/2007 3:43:17 PM