Service manual

11
D-26
4G9
ENGINE
-
Intake Manifold and Water Pump
9ENOO89
OFNnnol
Sealant
I
9EN0091
INSTALLATION SERVICE POINTS
I)A4
SEALANT APPLICATION TO WATER PUMP
Specified sealant:
Mitsubishi Genuine Part No. MD970389 or equiva-
lent
I)B4
WATER PIPE
/
O-RING INSTALLATION
(1)
Wet the O-ring (with water) to facilitate the assembly.
Caution
1. Keep the O-ring free of oil or grease.
2.
Secure the water pipe after the thermostat housing
has been installed.
I)c4
;‘dU;;;
APPLICATION TO THERMOSTAT
Specified sealant:
Mitsubishi Genuine Part No. MD970389 or equiva-
lent
I)D4
THERMOSTAT INSTALLATION
(1)
Install the thermostat in the thermostat housing in such a
way that the jiggle valve is located as illustrated.
+Eg
SEALANT APPLICATION TO ENGINE COOLANT
TEMPERATURE SENSOR
Specified sealant:
3M Nut Locking Part No. 4171 or equivalent
1
TSB Revision