User`s manual

6
External Connection Diagram (2) (64-point inputs, 16-point outputs)
DC12/24V
(12/24VDC)
A17,B17,A18
0109111921293139
020A121A222A323A
030B131B232B333B
040C141C242C343C
050D151D252D353D
060E161E262E363E
070F171F272F373F
XD1
XD2
XD3
XD4
XD5
XD6
XD7
A8
B7
A7
B6
A6
B5
A5
XSCN0
XSCN1
XSCN2
XSCN3
XSCN4
XSCN5
XSCN6
XSCN7
A16 YD1
B15 YD2
A15 YD3
B14 YD4
A14
YD5
B13 YD6
A13
YD7
B12 YD8
A12 YD9
B11 YD10
A11
YD11
B10 YD12
A10
YD13
B9
YD14
A9
YD15
R
R
B4
A4
B3
A3
B2
A2
B1
A1
XD0
B8
R
B16
R
YD0
L
L
B18,A19
+
-
0008101820283038
Pin number
Input terminals
Internal
control
circuit
Internal
control
circuit
Internal
control
circuit
Internal
scan is
made at
1/8 duty.
Fuse-blown
detector
circuit
*1: When there is a probability that two or more switches are
pressed simultaneously, each switch must be provided with a
diode. (Refer to the right figure.)
*2: A fuse-blown error will also be displayed when the external
supply power switches off.
*3: The fuse in the output unit is provided to prevent the external wiring from
burning out if the outputs of the unit are shorted.
Therefore, it may not protect the output elements.
The fuse may not be blown if the output elements are damaged in the
fault mode other than a short circuit.