Wall Cover Inlet (NW):
Use where piping penetrates the wall.
Align wall cover base with hole in the
wall, and fasten to wall with appropri-
ate screws. After completing tube
assembly, push the
tube downward (in
the direction of the
arrows) after aligning
the base with the
stopper built-in to the
top portion of wall
cover. This process will temporarily fasten wall cover.
Simple Wall Cover (NY):
One-piece inlet is used where refrigerant piping penetrates the
building wall.
Locate cover over Lineset, and mark mounting holes. Mount
and secure Line Tube to wall. Carefully bend refrigerant tubing,
drain and/or wiring into Line Tube. Place a bead of caulk on the
wall cover flange. Place Simple Wall Cover over wall opening,
and secure with appropriate screws and anchors.
Elbows – 90 degree horizontal (NE) and vertica l
(NC), 45 degree horizontal (NM) and vertical (NU),
and univeral horizonal (NX) and vertical (NZ):
Use where piping from the out-
door unit rises vertically or turns
horizontally along the wall.
Position the elbow base on the
wall where it will be fastened, and
attach to the wall with appropriate
screws. After installing tube, align
the elbow cover to the elbow
base, and attach with the stainless
steel screws provided.
All vertical elbows — NC, NU, NZ
— are reversible for use in both
inside and outside corner applica
-
tions. Cover screws can be insert-
ed in either direction required.
T
-Joint (NT):
Use where piping branches off.
To change tube size, use the appropriate adapter set.
Contents of Accessory Adapter Sets
NT-75 75mm-60mm adapter 2 sets
NT-100 100mm-60mm adapter 2 sets
100mm-75mm adapter 2 sets
NT-140 140mm-100mm adapter 2 sets
Fit the accessory adapter base
appropriate for the proper size tube
into the
T-Joint base. Fasten base of
T-Joint to wall with the appropriate
screws. After tube base is
installed and the lineset
positioned, and the tube
cover snapped on, attach
theT-Joint cover to the
T-Joint base with the stain-
less steel screws provided.
Socket/Coupling (NS):
Use to lengthen and extend
tubes and to prevent tube
cover from sliding.
Mark the length of the tube;
then position the socket base
so that the tube will abut the
molded plastic stop of the
socket; then attach the socket
to the wall with appropriate screws. After installing tube, align
cover with holes in socket base, and fasten with the stainless
steel screws provided.
Variant Socket/Reducer (NJ):
Use to connect Line Tubes of different sizes.
Before attaching base to wall, determine that the converter cor-
responds to the varying tube sizes you’ll be joining and that it is
oriented properly on the wall. Then attach with the appropriate
screws. Locate Line Tubes, and install covers. Place socket
covers over base; align holes, and fasten with stainless steel
screws provided.
Flexible Joint (NF):
Use where piping bends over protrusion (such
as side molding) on wall.
If your installation requires the use of flexible
joint,
INST
ALL IT FIRST
. Fle
xib
le joints are
not split.
Simply slide the flexible joint over the
piping, and secure it in place.
T
o connect flexible joint to Line
T
ube, slide end of the flexible
joint into the end of tube base, and fasten it with appropriate
screws.
T
o help ensure a tight fit, compress the bellows of the
flexible joint.
After the flexible joint is released, it will expand
against the tube to make a tight, strong connection. When the
assembly is complete, snap the tube cover onto the tube base
so that the end of the flexible joint is concealed.