Service manual

9 /
VSP-C0486
3.4 Power Supply
Input Voltage
100 - 120 / 220 - 240 VAC +/- 10%
Frequency
50/60Hz +/- 3Hz
Power Consumption (typical.)
125W 1.25A@100-120VAC 0.6A@220-240VAC
AC leakage current
<= 3.5mA
Inrush current
<=70A 0-peak at 240VAC on cold starting
3.5 Power Saving
H-sync V-sync Video
Power
Consumption
Recovery
Time
LED
Indicator
Power Saving OFF On On Active 125W Green
Off On Blank
On Off Blank
Power Saving ON
Off Off Blank
<= 2W Approx.5 sec Orange
3.6 Degaussing
Auto Degaussing The monitor have an automatic degaussing function which activates
when the unit is turned on.
Manual Degaussing This activates degaussing at the user's discretion after the unit is
Operating
*The Monitor requires minimum 15 minutes after last degauss operation for full
degauss capability